Uncertainties in the Measurement of AC Voltage Using a Programmable Josephson Voltage Standard and a Phase-Sensitive Null Detector

被引:4
作者
Georgakopoulos, Dimitrios [1 ]
机构
[1] Natl Measurement Inst, Lindfield, NSW 2070, Australia
关键词
Alternating-current (ac) voltage measurement; ac-direct-current (ac-dc) difference; Josephson arrays; programmable Josephson voltage standard (PJVS); thermal voltage converters (TVCs); ACCURACY; ARRAYS; ERROR;
D O I
10.1109/TIM.2011.2132210
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Providing the traceability of alternating-current (ac) voltage measurements by means of a stepwise-approximated sine wave (SASW) produced by a programmable Josephson voltage standard (PJVS) is an attractive alternative to the conventional ac voltage standards based on thermal voltage converters, because a programmable Josephson standard has a calculable output voltage that does not drift with time. This paper investigates two aspects of uncertainties in the measurement of ac voltage using a sine wave generated by a PJVS with a lock-in amplifier as a null detector. First, the uncertainty introduced by transitions between successive voltage levels of the SASW on the fundamental and root-mean-square values is examined. Second, the lock-in amplifier response to the harmonics of this synthesized sine wave is discussed. Experimental evaluation shows that harmonics that are not rejected by the lock-in amplifier can cause a systematic error when measuring the ac-direct-current difference of a thermal converter with the synthesized sine wave from 0.5 to 3.0 mu V/V, depending on the number of samples per period of the SASW. Furthermore, it is shown that this error can be reduced to 0.3 mu V/V by calibrating the lock-in amplifier using a distorted signal having a similar harmonic content to the synthesized sine wave.
引用
收藏
页码:2178 / 2183
页数:6
相关论文
共 26 条
[1]   Synthesis of precision waveforms using a SINIS Josephson junction array [J].
Behr, R ;
Williams, JA ;
Patel, P ;
Janssen, TJBM ;
Funck, T ;
Klonz, M .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (02) :612-615
[2]   Analysis of different measurement setups for a programmable Josephson voltage standard [J].
Behr, R ;
Kohlmann, J ;
Janssen, JTBM ;
Kleinschmidt, P ;
Williams, JM ;
Djordjevic, S ;
Lo-Hive, JP ;
Piquemal, F ;
Hetland, PO ;
Reymann, D ;
Eklund, G ;
Hof, C ;
Jeanneret, B ;
Chevtchenko, O ;
Houtzager, E ;
van den Brom, HE ;
Sosso, A ;
Andreone, D ;
Nissilä, J ;
Helistö, P .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (02) :524-528
[3]   Direct comparison of Josephson waveforms using an AC quantum voltmeter [J].
Behr, Ralf ;
Palafox, Luis ;
Ramm, Guenther ;
Moser, Harald ;
Melcher, Juergen .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) :235-238
[4]   Progress Toward a 1 V Pulse-Driven AC Josephson Voltage Standard [J].
Benz, Samuel P. ;
Dresselhaus, Paul D. ;
Ruefenacht, Alain ;
Bergren, Norman F. ;
Kinard, Joseph R. ;
Landim, Regis Pinheiro .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) :838-843
[5]  
BUDOVSKY I, 2009, P MSA2009 MARC AUSTR, P35
[6]  
BUDOVSKY I, 2008, P C CPEM, P650
[7]  
BUDOVSKY I, 2010, P C CPEM, P50
[8]   Error and transient analysis of stepwise-approximated sine waves generated by programmable Josephson voltage standards [J].
Burroughs, Charles J., Jr. ;
Ruefenacht, Alain ;
Benz, Samuel P. ;
Dresselhaus, Paul D. ;
Waltrip, Bryan C. ;
Nelson, Tom L. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2008, 57 (07) :1322-1329
[9]   Systematic Error Analysis of Stepwise-Approximated AC Waveforms Generated by Programmable Josephson Voltage Standards [J].
Burroughs, Charles J., Jr. ;
Ruefenacht, Alain ;
Benz, Samuel P. ;
Dresselhaus, Paul D. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) :761-767
[10]  
EKLUND G, 2008, P C CPEM, P374