Scaling analysis for the OSU AP600 test facility (APEX)

被引:95
作者
Reyes, JN [1 ]
Hochreiter, L
机构
[1] Oregon State Univ, Dept Nucl Engn, Radiat Ctr 116, Corvallis, OR 97331 USA
[2] Westinghouse Elect Corp, Pittsburgh, PA 15230 USA
关键词
D O I
10.1016/S0029-5493(98)00218-0
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, the authors summarize the key aspects of a state-of-the-art scaling analysis (Reyes et al., 1995. Westinghouse Electric Corporation, WCAP-14270) performed to establish the facility design and test conditions for the Advanced Plant Experiment (APEX) at Oregon State University (OSU). This scaling analysis represents the first, and most comprehensive, application of the Hierarchical Two-Tiered Scaling (H2TS) Methodology (Zuber, 1991. US Nuclear Regulatory Commission, Washington DC, NUREG/CR-5809) in the design of an integral system test facility. The APEX test facility, designed and constructed on the basis of this scaling analysis, is the most accurate geometric representation of a Westinghouse AP600 nuclear steam supply system. The OSU APEX test facility has sen ed to develop an essential component of the integral system database used to assess the AP600 thermal hydraulic safety analysis computer codes. (C) 1998 Elsevier Science S.A. All Fights reserved.
引用
收藏
页码:53 / 109
页数:57
相关论文
共 30 条
[1]  
*AM NAT STAND DEC, 1979, ANSIANS5124
[2]  
[Anonymous], 1985, NUREGCR4167
[3]  
[Anonymous], 1989, Turbulent mirror
[4]  
BOUCHER TJ, 1994, INEL940200
[5]  
BURTT JD, 1996, INEL940061
[6]  
DAVIS CB, 1996, INEL960395
[7]  
FLETCHER CD, 1996, INEL960400
[8]  
HENRY RE, 1971, ASME, V93, P179
[9]  
HOCHREITER LE, 1995, INT JOINT POW GEN C
[10]  
HOCHREITER LE, 1995, 1995 ANS WINT M AM N