Enantioseparation of phenylsuccinic acid by high speed counter-current chromatography using hydroxypropyl-β-cyclodextrin as chiral selector

被引:49
作者
Tong, Shengqiang [1 ,2 ]
Yan, Jizhong [1 ]
Guan, Yi-Xin [2 ]
Lu, Youming [1 ]
机构
[1] Zhejiang Univ Technol, Coll Pharmaceut Sci, Hangzhou 310032, Zhejiang, Peoples R China
[2] Zhejiang Univ, Dept Chem & Biol Engn, Hangzhou 310027, Peoples R China
关键词
Chiral separation; High speed counter-current; chromatography; Hydroxypropyl-beta-cyclodextrin; Phenylsuccinic acid; CENTRIFUGAL PARTITION CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; ENANTIOMER SEPARATION; PREPARATIVE ENANTIOSEPARATION; RESOLUTION; RECOGNITION; ELECTROPHORESIS; OPTIMIZATION; DERIVATIVES; CELLULOSE;
D O I
10.1016/j.chroma.2011.06.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High speed counter-current chromatography (HSCCC) was successfully applied to resolution of phenylsuccinic acid (PSA) with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral selector (CS). The two-phase solvent system composed of n-hexane-methyl tert-butyl ether-0.1 mol L(-1) phosphate buffer solution with pH = 2.51 (0.5:1.5:2, v/v/v) was selected. Influence factors involved in the chiral separation were investigated, including the concentration of chiral selector, pH value of the aqueous phase, the separation temperature, and the thermodynamic parameters of inclusion complex were calculated. The complex formation constants were determined using analytical instrument. Two HSCCC elution modes were studied and peak resolution equation was discussed. Under optimum separation conditions, 712 mg of PSA racemate was separated using preparative apparatus. The purities of both of the fractions including (+)-PSA and (-)-PSA from the preparative CCC separation were over 98.5% determined by HPLC and enantiomeric excess of (+)-PSA and (-)-PSA reached 97.6% and 98.6%, respectively. Recovery for the target compounds from the CCC fractions reached 80-82% yielding 285 mg of (+)-PSA and 292 mg of ()-PSA. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:5602 / 5608
页数:7
相关论文
共 28 条
[1]  
Ai P, 2006, CHINESE CHEM LETT, V17, P787
[2]   Preparative enantioseparation of DL-α-methylbenzylamine by high-speed countercurrent chromatography using L-(+)-tartaric acid as chiral selector [J].
Cai, Y. ;
Yan, Z. H. ;
Zi, M. ;
Yuan, L. M. .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (9-12) :1489-1495
[3]   Stereoselective analysis of benazepril and its stereoisomers by reversed-phase high-performance liquid chromatography on a chiral AGP column [J].
Cirilli, R ;
La Torre, F .
JOURNAL OF CHROMATOGRAPHY A, 1998, 818 (01) :53-60
[4]   RESOLUTION IN COUNTERCURRENT CHROMATOGRAPHY [J].
CONWAY, WD ;
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (12) :2195-2207
[5]  
CONWAY WD, 1990, COUNTER CURRENT CHRO, P357
[6]   Enantiomer separation by counter-current chromatography -: Optimisation and drawbacks in the use of L-proline derivatives as chiral selectors [J].
Delgado, B ;
Pérez, E ;
Santano, MC ;
Minguillón, C .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1092 (01) :36-42
[7]   Enantioseparations in counter-current chromatography and centrifugal partition chromatography [J].
Foucault, AP .
JOURNAL OF CHROMATOGRAPHY A, 2001, 906 (1-2) :365-378
[8]   Enantiomer separation by countercurrent chromatography using cinchona alkaloid derivatives as chiral selectors [J].
Franco, P ;
Blanc, J ;
Oberleitner, WR ;
Maier, NM ;
Lindner, W ;
Minguillón, C .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4175-4183
[9]  
FRANCO P, 2001, CHIRAL SEPARATION TE, P8
[10]   Preparative enantiomer separation of dichlorprop with a cinchona-derived chiral selector employing centrifugal partition chromatography and high-performance liquid chromatography:: A comparative study [J].
Gavioli, E ;
Maier, NM ;
Minguillón, C ;
Lindner, W .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5837-5848