Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass

被引:191
作者
Al-Sanea, Sami A. [1 ]
Zedan, M. F. [1 ]
机构
[1] King Saud Univ, Coll Engn, Dept Mech Engn, Riyadh 11421, Saudi Arabia
关键词
Optimum insulation thickness; Insulated building walls; Finite-volume method; Energy conservation; POINT-OF-VIEW; MULTILAYERED WALL; DECREMENT FACTOR; ENERGY-SAVINGS; TIME-LAG; OPTIMUM; TURKEY; ROOF; LOCATION; BEHAVIOR;
D O I
10.1016/j.apenergy.2011.02.036
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Dynamic thermal characteristics of insulated building walls with same thermal mass are studied numerically with optimized insulation thickness under steady periodic conditions using the climatic data of Riyadh. Insulation is effected through use of one, two and three layers of insulation, the locations of which are varied in order to achieve the best performance. Insulation layer(s) thicknesses are optimized by minimizing the total cost of insulation and energy consumption using the present worth method. The results show that the optimum thickness of a single insulation layer is independent of its location in the wall; and that, when more than one insulation layer is used, their total optimum thickness is the same as the optimum thickness of a single layer. As a consequence, walls thermal resistances (R-values) are equal under optimum conditions; however, peak load, time lag, and decrement factor are found to be substantially different. The best overall performance is achieved by a wall with three layers of insulation, each 26-mm-thick, placed at inside, middle and outside followed closely by a wall with two insulation layers, each 39-mm-thick, placed at middle and outside. Comparing performance of the best wall with that of a wall with one layer of insulation, 78-mm-thick, placed on the inside, the following improvements are achieved: 100% increase in time lag from 6 h to 12 h; 10-fold decrease in decrement factor; 20% decrease in both peak cooling and heating transmission loads, and 1.6% and 3.2% decrease in yearly cooling and heating transmission loads, respectively. It is emphasized that all walls have the same optimized R-value and same thermal mass and therefore all improvements achieved are solely due to the developed distribution of insulation layers. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3113 / 3124
页数:12
相关论文
共 32 条
  • [1] Al-Sanea S.a., 2001, Journal of Thermal Envelope and Building Science, V24, P275, DOI DOI 10.1106/07E7-FGCJ-MFF7-974W
  • [2] Al-Sanea S A., 2011, International Journal of Ambient Energy, V23, DOI DOI 10.1080/01430750.2002.9674880
  • [3] Al-Sanea S.A., 2000, Journal of King Saud University, V12, P285
  • [4] Al-Sanea S.A., 2003, Journal of Building Physics, V26, P285, DOI [10.1177/109719603027973, DOI 10.1177/109719603027973]
  • [5] Al-Sanea S.A., 2001, International Journal of Ambient Energy, V22, P59, DOI DOI 10.1080/01430750.2001.9675389
  • [6] Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model
    Al-Sanea, SA
    Zedan, MF
    Al-Ajlan, SA
    [J]. APPLIED ENERGY, 2005, 82 (04) : 313 - 330
  • [7] Adjustment factors for the ASHRAE clear-sky model based on solar-radiation measurements in Riyadh
    Al-Sanea, SA
    Zedan, MF
    Al-Ajlan, SA
    [J]. APPLIED ENERGY, 2004, 79 (02) : 215 - 237
  • [8] Optimized monthly-fixed thermo stat-setting scheme for maximum energy-savings and thermal comfort in air-conditioned spaces
    Al-Sanea, Sami A.
    Zedan, M. F.
    [J]. APPLIED ENERGY, 2008, 85 (05) : 326 - 346
  • [9] ALNAFEEZ I, 1990, HOUSING SCI, V14, P161
  • [10] COOLING LOAD RESPONSE FOR BUILDING WALLS COMPRISING HEAT STORING AND THERMAL INSULATING LAYERS
    ALTURKI, A
    ZAKI, GM
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1991, 32 (03) : 235 - 247