Coupling of single droplet micro-extraction with desorption electrospray ionization-mass spectrometry

被引:34
|
作者
Sun, Xiaobo [1 ]
Miao, Zhixin [1 ]
Yuan, Zongqian [1 ]
Harrington, Peter de B. [1 ]
Colla, Jennifer [1 ]
Chen, Hao [1 ]
机构
[1] Ohio Univ, Dept Chem & Biochem, Ctr Intelligent Chem Instrumentat, Athens, OH 45701 USA
基金
美国国家科学基金会;
关键词
Desorption electrospray ionization-mass; spectrometry; Single droplet micro-extraction; Single droplet analysis; Methamphetamine; Room temperature ionic liquid; Green chemistry; LIQUID-LIQUID MICROEXTRACTION; IONIC LIQUID; WATER SAMPLES; PHASE MICROEXTRACTION; HUMAN URINE; CHROMATOGRAPHY; METHAMPHETAMINE; DESI; METABOLITES;
D O I
10.1016/j.ijms.2010.07.024
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Single droplet micro-extraction (SDME) is a powerful preconcentration and purification technique for trace chemical analysis, but the detection of the resulting single droplet extract is often time-consuming with traditional detection methods such as GC/MS or LC/MS. In this study, desorption electrospray ionization-mass spectrometry (DESI-MS) was coupled with SDME to serve as a fast detection method for the first time, demonstrated by the trace analysis of methamphetamine (MA) in aqueous solution and the detection of an organic reaction product from an ionic liquid (IL). In the former application, three-phase liquid SDME was conducted to enrich MA in aqueous solution to an organic solvent and then to back-extract the analyte to a single aqueous droplet. Subsequent DESI-MS analysis can be performed either to a single droplet or multiple droplets in a row. The average enrichment factor obtained for MA was 390-fold. In the latter case, two-phase liquid SDME was conducted to directly extract the product of an organic reaction performed in a room temperature ionic liquid (i.e., the nucleophilic addition of aniline to phenyl isothiocyanate to form N,N'-diphenylthiourea in 1-butyl-3-methyl-imidazolium tetrafluoroborate). The ionization of the resulting droplet extract by DESI allows one to directly examine the reaction product without interference from the ionic liquid. Such an analysis uses a few microliters of an organic solvent, achieving green chemistry. This combined SDME/DESI-MS method is characterized with high preconcentration efficiency, high throughput capability and minimizing organic solvent waste. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 50 条
  • [21] Direct Analysis of Liquid Samples by Desorption Electrospray Ionization-Mass Spectrometry (DESI-MS)
    Miao, Zhixin
    Chen, Hao
    Journal of the American Society for Mass Spectrometry, 2009, 20 (01): : 10 - 19
  • [22] Intraoperative assessment of tumor margins during glioma resection by desorption electrospray ionization-mass spectrometry
    Pirro, Valentina
    Alfaro, Clint M.
    Jarmusch, Alan K.
    Hattab, Eyas M.
    Cohen-Gadol, Aaron A.
    Cooks, R. Graham
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (26) : 6700 - 6705
  • [23] Desorption electrospray ionization-mass spectrometry imaging of carnitine and imidazole dipeptides in pork chop tissues
    Enomoto H.
    Zaima N.
    Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, 2023, 1216
  • [24] Direct Analysis of Liquid Samples by Desorption Electrospray Ionization-Mass Spectrometry (DESI-MS)
    Miao, Zhixin
    Chen, Hao
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (01) : 10 - 19
  • [25] Investigation of novel sol–gel hydrophobic surfaces for desorption electrospray ionization-mass spectrometry analysis
    Andrea Penna
    Lisa Elviri
    Maria Careri
    Alessandro Mangia
    Giovanni Predieri
    Analytical and Bioanalytical Chemistry, 2011, 400 : 1515 - 1523
  • [26] Study of the desorption/ionization mechanism in electrospray droplet impact secondary ion mass spectrometry
    Asakawa, Daiki
    Hiraoka, Kenzo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (05) : 655 - 660
  • [27] Coupling Micropipette Tip-based Micro-extraction with Desorption Corona Beam Ionization Mass Spectrometry for Rapid Analysis of Antihypertensive Drugs in Body Fluid
    You Jin-Qing
    Hao Yan-Hong
    Huang Yun-Qing
    Cheng Yu-Peng
    Sun Wen-Jian
    Yu Qiong-Wei
    Yuan Bi-Feng
    Feng Yu-Qi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (03) : 319 - 324
  • [28] Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry
    Wang, Zheng
    Zhu, Haijing
    Huang, Guangming
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (23) : 1957 - 1962
  • [29] Single oocyte and single embryo lipid analysis by desorption electrospray ionization mass spectrometry
    Ferreira, C. R.
    Eberlin, L. S.
    Hallett, J. E.
    Cooks, R. G.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 29 - 33
  • [30] A study of cation attachment to polystyrene by means of matrix-assisted laser desorption/ionization and electrospray ionization-mass spectrometry
    Deery, MJ
    Jennings, KR
    Jasieczek, CB
    Haddleton, DM
    Jackson, AT
    Yates, HT
    Scrivens, JH
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (01) : 57 - 62