An organopalladium-PVC membrane for sulphur dioxide optical sensing

被引:24
作者
Alves, FL [1 ]
Raimundo, IM [1 ]
Gimenez, IF [1 ]
Alves, OL [1 ]
机构
[1] UNICAMP, Inst Quim, BR-13084971 Campinas, SP, Brazil
关键词
optical sensor; sulphur dioxide; gas sensor; organopalladium (I) complex;
D O I
10.1016/j.snb.2004.07.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a sensing membrane for the determination of gaseous sulphur dioxide is described. An organopalladium complex, Pd-2(dpm)(2)Cl-2 (dichloro-bis-(diphenylphosphine)-methane dipalladium I), was immobilised in a poly(vinyl chloride) thin film plasticised with ortho-nitrophenyloctylether (o-NPOE). Several membranes were prepared, using 20, 25 and 30% of PVC; 1, 5 and 8% of palladium complex and enough o-NPOE to make a total of 100 mg, which was dissolved in 1.0 mL of THE The sensing membranes were obtained by manual deposition of 10, 15 and 20 mu L of the solution onto cellulose acetate films, which were left to dry for 24 h and then stored in a desiccator sheltered from ambient light. The membrane was placed in an acrylic flow cell, in which the common end of a bifurcated optical fibre bundle was adapted and placed 1 mm from the membrane. Reflectance measurements were performed from 400 to 800 nm, after exposing the membrane to 0 to 500 ppm(v) of SO2 in air, at a flow rate of 500 mL min(-1). The membrane composed of 20% PVC, 72% o-NPOE and 8% palladium complex showed the best performance and the film prepared from 20 mu l of solution provided the highest signal (ca 160 mV upon exposure to 500 ppm(v) SO2). Measurements made at 530 mn showed a linear response range up to 300 ppm(v), with a detection limit of 3.5 ppm(v). By employing a flow rate of 500 mL min(-1), response times (t(90%)) of 3 and 2 min were obtained for reaction of the membrane with SO, and for reverse response upon exposure to dry nitrogen, respectively. Although the palladium complex also reacts with carbon monoxide in solution, this interference was not observed for concentrations up to 1000 ppm(v) of CO. The membrane showed a lifetime of ca. 2 months when stored in a desiccator. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 24 条
[1]   NOVEL REACTIONS OF METAL-METAL BONDS - ADDITION OF SULFUR-DIOXIDE AND SULFUR TO PD2(PH2PCH2PPH2)2CL2 AND THE OXIDATION OF COORDINATED SULFIDE [J].
BALCH, AL ;
BENNER, LS ;
OLMSTEAD, MM .
INORGANIC CHEMISTRY, 1979, 18 (11) :2996-3003
[2]   NOVEL REACTIONS OF METAL-METAL BONDS - INSERTION OF ISOCYANIDES AND CARBON-MONOXIDE INTO PALLADIUM-PALLADIUM BOND OF SOME PD(I) DIMERS [J].
BENNER, LS ;
BALCH, AL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1978, 100 (19) :6099-6106
[3]  
BENNER LS, 1978, J ORGANOMET CHEM, V153, P31
[4]   Polymeric films in optical gas sensors [J].
Brook, TE ;
Narayanaswamy, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :77-83
[5]   Determination of sulfite by flow injection analysis using a poly [Ni-(protoporphyrin IX)] chemically modified electrode [J].
Carballo, R ;
Dall'Orto, VC ;
Lo Balbo, A ;
Rezzano, I .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (02) :155-161
[6]   Amperometric SO2 gas sensors based on solid polymer electrolytes [J].
Chiou, CY ;
Chou, TC .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) :1-7
[7]   Oxygen-sensitive reverse-phase optode membrane using silica gel-adsorbed ruthenium(II) complex embedded in gelatin film [J].
Choi, MMF ;
Xiao, D .
ANALYTICA CHIMICA ACTA, 1999, 387 (02) :197-205
[8]   Reagentless system for sulphite determination based on polyaniline [J].
de Marcos, S ;
Alcubierre, N ;
Galbán, J ;
Castillo, JR .
ANALYTICA CHIMICA ACTA, 2004, 502 (01) :7-13
[9]   FIBER OPTIC SENSOR FOR NOX [J].
FREEMAN, MK ;
BACHAS, LG .
ANALYTICA CHIMICA ACTA, 1992, 256 (02) :269-275
[10]  
GIMENEZ IF, 2002, GLASS TECHNOL, P166