Minimum analgesic dose of epidural sufentanil for first-stage labor analgesia - A comparison between spontaneous and prostaglandin-induced labors in nulliparous women

被引:39
作者
Capogna, G
Parpaglioni, R
Lyons, G
Columb, M
Celleno, D
机构
[1] Fatebenefratelli Gen Hosp, AFaR CRCCS, Dept Anesthesia, I-00186 Rome, Italy
[2] Fatebenefratelli Gen Hosp, Dept Anesthesia & Intens Care, Rome, Italy
关键词
D O I
10.1097/00000542-200105000-00009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The aim of this prospective, double-blind, sequential allocation study was to compare the effects of spontaneous and prostaglandin-induced labor on the minimum analgesic dose of epidural sufentanil in the first stage of labor. Methods: Seventy healthy, nulliparous women, at more than 37 weeks' gestation with cervical dilatation from 2 to 4 cm, requesting epidural pain relief in labor were enrolled. The subjects were assigned to two different groups according to whether labor was spontaneous or induced with dinoprostone 0.5 mg. Parturients received 10 ml of the study solution through a lumbar epidural catheter. The Initial dose was sufentanil 25 mug, and subsequent doses were determined by the response of the previous patient in the same group using up-down sequential allocation. The analgesic effectiveness was assessed using 100-mm visual analog pain scores. The up-down sequences were analyzed using the method of independent paired reversals and probit regression. Results: The minimum analgesic dose of sufentanil in spontaneous labor was 22.2 mug (95% CI: 19.6, 22.8) and 27.3 mug (95% CI: 23.8, 30.9) in induced labor. The minimum analgesic dose of sufentanil in induced labor was significantly greater (P = 0.0014) than that in spontaneous labor (95% CI difference: 2.9, 9.3) by a factor of 1.3 (95% CI: 1.1, 1.5). Conclusion: Prostaglandin induction of labor produces a significantly greater analgesic requirement than does spontaneous labor.
引用
收藏
页码:740 / 744
页数:5
相关论文
共 26 条
  • [1] Bueno L, 1999, Can J Gastroenterol, V13 Suppl A, p42A
  • [2] CAPOGNA G, 1989, REGION ANESTH, V14, P282
  • [3] Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour
    Capogna, G
    Celleno, D
    Lyons, G
    Columb, M
    Fusco, P
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) : 11 - 13
  • [4] EPIDURAL FENTANYL IN LABOR
    CARRIE, LES
    OSULLIVAN, GM
    SEEGOBIN, R
    [J]. ANAESTHESIA, 1981, 36 (10) : 965 - 969
  • [5] Mechanical sensitization of cutaneous C-fiber nociceptors by prostaglandin E2 in the rat
    Chen, XJ
    Tanner, K
    Levine, JD
    [J]. NEUROSCIENCE LETTERS, 1999, 267 (02) : 105 - 108
  • [6] DETERMINATION OF THE MINIMUM LOCAL ANALGESIC CONCENTRATIONS OF EPIDURAL BUPIVACAINE AND LIDOCAINE IN LABOR
    COLUMB, MO
    LYONS, G
    [J]. ANESTHESIA AND ANALGESIA, 1995, 81 (04) : 833 - 837
  • [7] COLUMB MO, 1999, ANESTHESIOLOGY S, V90, pA73
  • [8] HYPERALGESIC EFFECTS OF PROSTACYCLIN AND PROSTAGLANDIN-E2
    FERREIRA, SH
    NAKAMURA, M
    CASTRO, MSDA
    [J]. PROSTAGLANDINS, 1978, 16 (01): : 31 - 37
  • [9] A CONTROLLED TRIAL OF EXTRADURAL FENTANYL IN LABOR
    JUSTINS, DM
    FRANCIS, D
    HOULTON, PG
    REYNOLDS, F
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (04) : 409 - 414
  • [10] PLACENTAL-TRANSFER AND NEONATAL EFFECTS OF EPIDURAL SUFENTANIL AND FENTANYL ADMINISTERED WITH BUPIVACAINE DURING LABOR
    LOFTUS, JR
    HILL, H
    COHEN, SE
    [J]. ANESTHESIOLOGY, 1995, 83 (02) : 300 - 308