Determination of the source and severity of a transvalvular left ventricular outflow tract gradient in patients with a prosthetic aortic valve

被引:0
作者
Ragosta, Michael [1 ]
机构
[1] Univ Virginia Hlth Syst, Cardiac Catheterizat Labs, Div Cardiovasc, Dept Med, Charlottesville, VA 22908 USA
关键词
hemodynamics; prosthetic valve dysfunction; aortic stenosis;
D O I
10.1002/ccd.21340
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:809 / 814
页数:6
相关论文
共 18 条
  • [1] DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY
    BAUMGARTNER, H
    KHAN, S
    DEROBERTIS, M
    CZER, L
    MAURER, G
    [J]. CIRCULATION, 1990, 82 (04) : 1467 - 1475
  • [2] Net pressure gradients in aortic prosthetic valves can be estimated by Doppler
    Bech-Hanssen, O
    Gjertsson, P
    Houltz, E
    Wranne, B
    Ask, P
    Loyd, D
    Caidahl, K
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (08) : 858 - 866
  • [3] Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: An in vivo and in vitro study
    Bech-Hanssen, O
    Caidahl, K
    Wallentin, I
    Ask, P
    Wranne, B
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (02) : 287 - 295
  • [4] Utilization of a pressure sensor guidewire to measure bileaflet mechanical valve gradients: Hemodynamic and echocardiographic sequelae
    Doorey, AJ
    Gakhal, M
    Pasquale, MJ
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 67 (04) : 535 - 540
  • [5] Kern MJ, 1998, CATHETER CARDIO DIAG, V44, P336
  • [6] CATHETER ENTRAPMENT IN A BJORK-SHILEY PROSTHESIS IN AORTIC POSITION
    KOBER, G
    HILGERMANN, R
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1987, 13 (04): : 262 - 265
  • [7] Pressure gradients across bileaflet aortic valves by direct measurement and echocardiography
    Laske, A
    Jenni, R
    Maloigne, M
    Vassalli, G
    Bertel, O
    Turina, MI
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (01) : 48 - 57
  • [8] Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude medical mechanical prostheses in the aortic position
    Mohty-Echahidi, D
    Malouf, JF
    Girard, SE
    Schaff, HV
    Grill, DE
    Enriquez-Sarano, ME
    Miller, FA
    [J]. CIRCULATION, 2006, 113 (03) : 420 - 426
  • [9] Retrograde left ventricular hemodynamic assessment across bileaflet prosthetic aortic valves: The use of a high-fidelity pressure sensor angioplasty guidewire
    Parham, W
    El Shafei, A
    Rajjoub, H
    Ziaee, A
    Kern, MJ
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (04) : 509 - 513
  • [10] Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
    Pibarot, P
    Dumesnil, JG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) : 1131 - 1141