Determination of Risperidone and 9-Hydroxyrisperidone in Human Serum by Heart-Cutting Isocratic Two-Dimensional Liquid Chromatography

被引:13
|
作者
Liu, Wei [1 ]
Jin, Xiaoxia [1 ]
Yao, Shuyong [1 ]
Wang, Feng [2 ]
机构
[1] Soochow Univ, Affiliated Guangji Hosp, Dept Pharm, 11 Guangqian Rd, Suzhou 215000, Jiangsu, Peoples R China
[2] Cent South Univ, Xiangya Hosp 2, Dept Pharm, 139 Renmin Zhong Rd, Changsha 410011, Hunan, Peoples R China
关键词
High-performance liquid chromatography (HPLC); risperidone; therapeutic drug monitoring; two-dimensional liquid chromatography; 9-hydroxyrisperidone; DRIED BLOOD SPOTS; ANTIPSYCHOTIC-DRUGS; ATYPICAL ANTIPSYCHOTICS; CONSENSUS GUIDELINES; RECEPTOR OCCUPANCY; PERFORMANCE; PLASMA; QUANTIFICATION; OPTIMIZATION; SEPARATIONS;
D O I
10.1080/00032719.2020.1728291
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study reports a novel heart-cutting two-dimensional high performance liquid chromatography (2D-LC) method with ultraviolet detection for the determination of risperidone and 9-hydroxyrisperidone in human serum. In this 2D system, a strong cation-exchange column was applied for the first dimensional (D-1) separation to isolate the targets from the complex serum matrices, and a middle column was used to transfer the targets from the first dimension to the second dimension (D-2) through a six-port valve. A reverse-phase C18 column was selected in the second dimension for further separation. An assistant pump was optimized to prevent the peak dispersion and the loss of resolution. This method has the advantages of high sensitivity by large injection volume, simple one-step sample preparation and short analysis time. A linear range between 5 and 146 ng/mL for risperidone and 7 and 200 ng/mL for 9-hydroxyrisperidone was achieved. All of the results showed that the coupling of ion-exchange with reversed-phase liquid chromatography had powerful separation capabilities for risperidone and 9-hydroxyrisperidone in human serum. The method exhibited good repeatability and recoveries and may be used as a reliable approach for therapeutic drug monitoring in clinical analysis.
引用
收藏
页码:2002 / 2019
页数:18
相关论文
共 50 条
  • [21] The use of a temperature-responsive column for the direct analysis of drugs in serum by two-dimensional heart-cutting liquid chromatography
    Mikuma, Toshiyasu
    Uchida, Ryo
    Kajiya, Mizuki
    Hiruta, Yuki
    Kanazawa, Hideko
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (04) : 1059 - 1065
  • [22] The analysis of carbohydrates in milk powder by a new "heart-cutting" two-dimensional liquid chromatography method
    Ma, Jing
    Hou, Xiaofang
    Zhang, Bing
    Wang, Yunan
    He, Langchong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 91 : 24 - 31
  • [23] The use of a temperature-responsive column for the direct analysis of drugs in serum by two-dimensional heart-cutting liquid chromatography
    Toshiyasu Mikuma
    Ryo Uchida
    Mizuki Kajiya
    Yuki Hiruta
    Hideko Kanazawa
    Analytical and Bioanalytical Chemistry, 2017, 409 : 1059 - 1065
  • [24] The versatility of heart-cutting and comprehensive two-dimensional liquid chromatography in monoclonal antibody clone selection
    Sandra, Koen
    Steenbeke, Mieke
    Vandenheede, Isabel
    Vanhoenacker, Gerd
    Sandra, Pat
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1523 : 283 - 292
  • [26] Quantitative analysis of cembranoids in tobacco leaf by using heart-cutting two-dimensional liquid chromatography
    Chen, Min
    Dong, Huizhong
    Shen, Shihao
    Wang, Jiale
    Wu, Da
    Liu, Baizhan
    SEPARATION SCIENCE PLUS, 2019, 2 (04) : 112 - 119
  • [27] Simultaneous separation and determination of several chiral antidepressants and their enantiomers in wastewater by online heart-cutting two-dimensional liquid chromatography
    Zhong, Jinjian
    Liu, Xin
    Chen, Linzhou
    Li, Kan
    Hu, Qingkun
    Wu, Ke
    Zhou, Jidan
    Shi, Yuesen
    Fan, Huajun
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2023, 263
  • [28] Determination of risperidone and 9-hydroxyrisperidone in human plasma by high-performance liquid chromatography: application to therapeutic drug monitoring in Japanese patients with schizophrenia
    Nagasaki, T
    Ohkubo, T
    Sugawara, K
    Yasui, N
    Furukori, H
    Kaneko, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (3-4) : 595 - 601
  • [29] Therapeutic drug monitoring of risperidone and 9-hydroxyrisperidone in serum with solid-phase extraction and high-performance liquid chromatography
    Price, MC
    Hoffman, DW
    THERAPEUTIC DRUG MONITORING, 1997, 19 (03) : 333 - 337
  • [30] Application of fractionized sampling and stacking for construction of an interface for online heart-cutting two-dimensional liquid chromatography
    Ji, Baocheng
    Xia, Bing
    Liu, Jie
    Gao, Yuanji
    Ding, Lisheng
    Zhou, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1466 : 199 - 204