Best implant choice for coracoid graft fixation during the Latarjet procedure depends on patients' morphometric considerations

被引:4
作者
Boutsiadis, Achilleas [1 ]
Bampis, Ioannis [1 ]
Swan, John [2 ]
Barth, Johannes [2 ]
机构
[1] 401 Mil Hosp Athens, Dept Orthoped Surg, Athens, Greece
[2] Ctr Osteoarticulaire Cedres, Dept Orthopaed Surg, Parc Sud Galaxie,5 Rue Trop, F-38130 Grenoble, France
关键词
Coracoid dimensions; Glenoid dimensions; Latarjet technique; Latarjet implants; Glenoid bone loss; GLENOID BONE LOSS; QUANTITATIVE ASSESSMENT; INSTABILITY; OUTCOMES; RESTORE; REPAIR;
D O I
10.1186/s40634-020-00230-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To assess the anthropometric dimensions of the coracoid process and the glenoid articular surface and to determine possible implications with the different commercially available Latarjet fixation techniques. Methods In a total of 101 skeletal scapulae the glenoid length (GL), the glenoid width (GW), the coracoid length (CL), the coracoid width (CW) and the coracoid thickness (CTh) were measured. In order to assess the ability of the transferred coracoid to restore the glenoid anatomy we created a hypothetical model of 10%, 15%, 20%, 25% and 30% glenoid bone loss. We analyzed four common surgical fixation techniques for the Latarjet procedure (4.5 mm screws, 3.75 mm screws, 3.5 mm screws, and 2.8 mm button). The distances from the superior-inferior and medio-lateral limits of the coracoid using the four different fixation methods were calculated. We hypothesized that the "safe distance" between the implant and the coracoid osteotomy should be at least equal to the diameter of the implant. Results The intra and inter-observer reliability tests were almost perfect for all measurements. The mean GH was 36.8 +/- 2.5 mm, the GW 26.4 +/- 2.2 mm, the CL 23.9 +/- 3 mm, the CW 13.6 +/- 2.mm, and the mean CTh was 8.7 +/- 1.3 mm. The CL was < 25 mm in 46% of the cases. In cases with 25% and 30% bone loss, the coracoid graft restored the glenoid anatomy in 96% and 79.2% of the cases. With the use of the 4.5 mm screws the "safe distance" was present in 56% of the cases, with the 3.75 mm screws in 85%, with the 3.5 mm screws in 87%, and with the 2.8 mm button in 98% of the cases. The distance from the medio-lateral limit of the coracoid could be significantly increased (up to 9 mm) when smaller-button implants are used. Conclusions The coracoid graft could not always restore glenoid defects of 30%. Larger implants could be positioned too close to the osteotomy and the "medio-lateral offset" of the coracoid could be increased with smaller implants.
引用
收藏
页数:8
相关论文
共 31 条
[1]  
Assunção Jorge Henrique, 2019, Rev. bras. ortop., V54, P483, DOI 10.1016/j.rbo.2017.12.006
[2]   Arthroscopic Latarjet: Suture-Button Fixation Is a Safe and Reliable Alternative to Screw Fixation [J].
Boileau, Pascal ;
Saliken, David ;
Gendre, Patrick ;
Seeto, Brian L. ;
d'Ollonne, Thomas ;
Gonzalez, Jean-Francois ;
Bronsard, Nicolas .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (04) :1050-1061
[3]  
Buckley R., 2018, AO PRINCIPLES FRACTU, V1
[4]   Evolving Concept of Bipolar Bone Loss and the Hill-Sachs Lesion: From "Engaging/Non-Engaging" Lesion to "On-Track/Off-Track" Lesion [J].
Di Giacomo, Giovanni ;
Itoi, Eiji ;
Burkhart, Stephen S. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (01) :90-98
[5]   An anatomic study of the coracoid process as it relates to bone transfer procedures [J].
Dolan, Christopher M. ;
Hariri, Sanaz ;
Hart, Nathan D. ;
McAdams, Timothy R. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (03) :497-501
[6]  
Domos Peter, 2018, Shoulder Elbow, V10, P15, DOI 10.1177/1758573217728716
[7]   Anatomic Variation in Morphometry of Human Coracoid Process among Asian Population [J].
Fathi, Manal ;
Cheah, Pike-See ;
Ahmad, Umar ;
Nasir, M. Nizlan ;
San, Aye Aye ;
Rahim, Ezamin Abdul ;
Hussin, Paisal ;
Mahmud, Rozi ;
Othman, Fauziah .
BIOMED RESEARCH INTERNATIONAL, 2017, 2017
[8]   Coracoid bone block fixation with cortical buttons: An alternative to screw fixation? [J].
Gendre, P. ;
Thelu, C. -E. ;
d'Ollonne, T. ;
Trojani, C. ;
Gonzalez, J. -F. ;
Boileau, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (08) :983-987
[9]   Three-dimensional volume measurement of coracoid graft osteolysis after arthroscopic Latarjet procedure [J].
Haeni, David L. ;
Opsomer, Gaetan ;
Sood, Amit ;
Munji, Jeremy ;
Sanchez, Matthieu ;
Villain, Benoit ;
Walch, Gilles ;
Lafosse, Laurent .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (03) :484-489
[10]   Repair of an Anteroinferior Glenoid Defect by the Latarjet Procedure: Quantitative Assessment of the Repair by Computed Tomography [J].
Hantes, Michael E. ;
Venouziou, Aaron ;
Bargiotas, Konstantinos A. ;
Metafratzi, Zafiria ;
Karantanas, Apostolos ;
Malizos, Konstantinos N. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (08) :1021-1026