Sensitive sandwich immunoassay based on single particle mode inductively coupled plasma mass spectrometry detection

被引:44
作者
Liu, Rui [1 ,2 ]
Xing, Zhi [1 ]
Lv, Yi [2 ]
Zhang, Sichun [1 ]
Zhang, Xinrong [1 ]
机构
[1] Tsinghua Univ, Dept Chem, Key Lab Atom & Mol Nanosci, Minist Educ, Beijing 100084, Peoples R China
[2] Sichuan Univ, Coll Chem, Minist Educ, Key Lab Green Chem & Technol, Chengdu 610064, Peoples R China
关键词
Inductively coupled plasma mass spectrometry (ICP-MS); Sandwich immunoassay; Single particle; Time resolved analysis; Colloidal gold; IgG; ATRIAL-NATRIURETIC-PEPTIDE; ELEMENT-TAGGED IMMUNOASSAY; ICP-MS; GOLD NANOPARTICLES; PROTEIN; COMBINATION; ANTIBODY; TAGS;
D O I
10.1016/j.talanta.2010.08.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive sandwich type immunoassay has been proposed with the detection by inductively coupled plasma mass spectrometry (ICP-MS) in a single particle mode (time resolved analysis) The signal induced by the flash of ions (Au-197(+)) due to the ionization of single Au-nanoparticle (Au-NP) label in the plasma torch can be measured by the mass spectrometer The frequency of the transient signals is proportional to the concentration of Au-NPs labels Characteristics of the signals obtained from Au-NPs of 20 45 and 80 nm in diameters were discussed The analytical figures for the determination of Au-labeled IgG using ICP-MS in conventional integral mode and single particle mode were compared in detail Rabbit-anti-human IgG was used as a model analyte in the sandwich immunoassay A detection limit (3 sigma) of 01 ng mL(-1) was obtained for rabbit-anti-human IgG after immunoreactions with a linear range of 0 3-10 ng mL(-1) and a RSD of 8 1% (2 0 ng mL(-1)) Finally the proposed method was successfully applied to spiked rabbit-anti-human IgG samples and rabbit-anti-human serum samples The method resulted to be a highly sensitive ICP-MS based sandwich type immunoassay (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:48 / 54
页数:7
相关论文
共 37 条
[1]   Mass Cytometry: Technique for Real Time Single Cell Multitarget Immunoassay Based on Inductively Coupled Plasma Time-of-Flight Mass Spectrometry [J].
Bandura, Dmitry R. ;
Baranov, Vladimir I. ;
Ornatsky, Olga I. ;
Antonov, Alexei ;
Kinach, Robert ;
Lou, Xudong ;
Pavlov, Serguei ;
Vorobiev, Sergey ;
Dick, John E. ;
Tanner, Scott D. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :6813-6822
[2]   A sensitive and quantitative element-tagged immunoassay with ICPMS detection [J].
Baranov, VI ;
Quinn, Z ;
Bandura, DR ;
Tanner, SD .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1629-1636
[3]   The synergy of elemental and biomolecular mass spectrometry: new analytical strategies in life sciences [J].
Becker, J. Sabine ;
Jakubowski, Norbert .
CHEMICAL SOCIETY REVIEWS, 2009, 38 (07) :1969-1983
[4]   Determination of peanut allergens in cereal-chocolate-based snacks: metal-tag inductively coupled plasma mass spectrometry immunoassay versus liquid chromatography/electrospray ionization tandem mass spectrometry [J].
Careri, Maria ;
Elviri, Lisa ;
Maffini, Monica ;
Mangia, Alessandro ;
Mucchino, Claudio ;
Terenghi, Mattia .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (06) :807-811
[5]   Element-tagged immunoassay with inductively coupled plasma mass spectrometry for multianalyte detection [J].
Careri, Maria ;
Elviri, Lisa ;
Mangia, Alessandro .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (01) :57-61
[6]  
Clerico A, 2000, CLIN CHEM, V46, P1529
[7]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[8]   Gold colloid analysis by inductively coupled plasma-mass spectrometry in a single particle mode [J].
Degueldre, C ;
Favarger, PY ;
Wold, S .
ANALYTICA CHIMICA ACTA, 2006, 555 (02) :263-268
[9]   Reaction cell inductively coupled plasma mass spectrometry-based immunoassay using ferrocene tethered hydroxysuccinimide ester as label for the determination of 2,4-dichlorophenoxyacetic acid [J].
Deng, AP ;
Liu, HT ;
Jiang, SJ ;
Huang, HJ ;
Ong, CW .
ANALYTICA CHIMICA ACTA, 2002, 472 (1-2) :55-61
[10]   Magnetic bead-based chemiluminescent metal immunoassay with a colloidal gold label [J].
Fan, AP ;
Lau, CW ;
Lu, JZ .
ANALYTICAL CHEMISTRY, 2005, 77 (10) :3238-3242