A LabVIEW® based generic CT scanner control software platform

被引:43
作者
Dierick, M. [1 ]
Van Loo, D. [1 ]
Masschaele, B. [1 ]
Boone, M. [1 ]
Van Hoorebeke, L. [1 ]
机构
[1] Univ Ghent, Dept Phys & Astron, Ctr Xray Tomog, UGCT, B-9000 Ghent, Belgium
关键词
X-ray tomography; software; LabVIEW; MICRO-CT; ALGORITHM; FIELD;
D O I
10.3233/XST-2010-0268
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
UGCT, the Centre for X-ray tomography at Ghent University (Belgium) does research on X-ray tomography and its applications. This includes the development and construction of state-of-the-art CT scanners for scientific research. Because these scanners are built for very different purposes they differ considerably in their physical implementations. However, they all share common principle functionality. In this context a generic software platform was developed using LabVIEW (R) in order to provide the same interface and functionality on all scanners. This article describes the concept and features of this software, and its potential for tomography in a research setting. The core concept is to rigorously separate the abstract operation of a CT scanner from its actual physical configuration. This separation is achieved by implementing a sender-listener architecture. The advantages are that the resulting software platform is generic, scalable, highly efficient, easy to develop and to extend, and that it can be deployed on future scanners with minimal effort.
引用
收藏
页码:451 / 461
页数:11
相关论文
共 10 条
[1]   In vivo small-animal imaging using micro-CT and digital subtraction angiography [J].
Badea, C. T. ;
Drangova, M. ;
Holdsworth, D. W. ;
Johnson, G. A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) :R319-R350
[2]  
BARRETT HH, 2008, NUCL INSTRUM METH A, V584, P135
[3]   A dynamic micro-CT scanner based on a carbon nanotube field emission x-ray source [J].
Cao, G. ;
Lee, Y. Z. ;
Peng, R. ;
Liu, Z. ;
Rajaram, R. ;
Calderon-Colon, X. ;
An, L. ;
Wang, P. ;
Phan, T. ;
Sultana, S. ;
Lalush, D. S. ;
Lu, J. P. ;
Zhou, O. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08) :2323-2340
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   Cone-beam Micro-CT system based on LabVIEW software [J].
Ionita, Ciprian N. ;
Hoffmann, Keneth R. ;
Bednarek, Daniel R. ;
Chityala, Ravishankar ;
Rudin, Stephen .
JOURNAL OF DIGITAL IMAGING, 2008, 21 (03) :296-305
[6]  
Kak AvinashC., 2001, CLASSICS APPL MATH, V33
[7]   Cone-beam filtered-backprojection algorithm for truncated helical data [J].
Kudo, H ;
Noo, F ;
Defrise, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2885-2909
[8]  
Vlassenbroeck J, 2007, MICROSC MICROANAL, V13, P184, DOI 10.1017/S1431927607077379
[9]   Software tools for quantification of X-ray microtomography [J].
Vlassenbroeck, J. ;
Dierick, M. ;
Masschaele, B. ;
Cnudde, V. ;
Van Hoorebeke, L. ;
Jacobs, P. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) :442-445
[10]  
2008, J XRAY SCI TECHNOLOG, V16, P261