Impact of Respiratory Velocity On Target Volume Using 4DCT

被引:0
|
作者
Nakamura, M.
Narita, Y.
Matsugi, K.
Matsuo, Y.
Nakata, M.
Mizowaki, T.
Hiraoka, M.
机构
关键词
D O I
10.1118/1.2962622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
TU-EE-A306
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Target localization accuracy in a respiratory phantom using BrainLab ExacTrac and 4DCT imaging
    Matney, Jason E.
    Parker, Brent C.
    Neck, Daniel W.
    Henkelmann, Greg
    Rosen, Isaac I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (02): : 301 - 309
  • [2] The impact of irregular respiratory patterns on tumour volumes in 4DCT
    Huizing, E.
    Van Dieren, E. B.
    Bruggink, R.
    Woutersen, D.
    Slump, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S443 - S444
  • [3] Importance of 4DCT for Target Volume Definition in Stereotactic Lung Radiotherapy
    Goksel, E.
    Cone, D.
    Tezcanli, E.
    Kucucuk, H.
    Senkesen, O.
    Yilmaz, M.
    Garipagaoglu, M.
    Aslay, I.
    Sengoz, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 172 - 172
  • [4] Velocity-Based Selection of Gating Phases Using 4DCT Respiratory Waveform Analysis
    Manohar, N.
    Wang, T.
    Yang, X.
    Dresser, S.
    Patel, P.
    Higgins, K.
    Liu, T.
    Dhabaan, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E504 - E504
  • [5] Planning Target Volume Determination of Internal Mammary Nodes in Breast Cancer using 4DCT
    Jermoumi, M.
    James, S. M.
    Ferguson, C. L.
    Barrett, J. T.
    Huh, C.
    Al-Basheer, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E544 - E545
  • [6] Internal Target Volume (ITV) Uncertainties using Maximum Intensity Projection (MIP) from 4DCT
    Watkins, W.
    Li, R.
    Lewis, J.
    Sandhu, A.
    Jiang, S. B.
    Song, W. Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S589 - S589
  • [7] Impact of respiratory motion on dose distributions and DVHs of thoracic structures - Evaluation using 4DCT
    Liu, H
    Wei, X
    Jang, S
    Jauregui, M
    Dong, L
    Batter, P
    Luo, D
    Pan, T
    Hunjan, S
    Starkschall, G
    Rosen, I
    Prado, K
    Liao, Z
    Chang, J
    Komaki, R
    Mohan, R
    MEDICAL PHYSICS, 2005, 32 (06) : 1924 - 1924
  • [8] Target volume margins: position variations of pancreatic intratumoral fiducials on 4DCT and CBCT
    Van der Horst, A.
    Lens, E.
    Wognum, S.
    De Jong, R.
    Kroon, P. S.
    Fajardo, R. Davila
    Fockens, P.
    Van Hooft, J. E.
    Van Tienhoven, G.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S90 - S90
  • [9] Selection of External Surrogate for 4DCT Sorting: Does It Impact Target Delineation?
    Glide-Hurst, C.
    Bellon, M.
    Chetty, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Autosegmentation and internal target volume (ITV) generation in 4DCT lung imaging using deformable image registration
    Samant, S.
    Xia, J.
    Huang, M.
    Chung, H.
    Liu, C.
    Palta, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2326 - 2326