Absorbable self-reinforced polylactide (SR-PLLA) rods vs rigid rods (K-wire) in spinal fusion:: an experimental study in rabbits

被引:18
作者
Bezer, M
Yildirim, Y
Erol, B
Güven, O
机构
[1] Hosp Univ Marmara, Dept Orthopaed Surg, TR-81301 Istanbul, Turkey
[2] Acibadem Hosp, Dept Orthopaed Surg, TR-81070 Istanbul, Turkey
[3] Marmara Univ, Sch Med, Dept Orthoped Surg, TR-81301 Istanbul, Turkey
关键词
polylactide (PLLA) rod; spine fusion; experimental;
D O I
10.1007/s00586-004-0781-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Several clinical and experimental reports have evaluated the spinal application of bioabsorbable material for plating the anterior lumbar and cervical spine, and in anterior and posterior lumbar interbody spinal fusion. Nevertheless, the use of these materials in posterolateral interlaminar fusion has yet to be elucidated in the literature. The effects of bioabsorbable self-reinforced polylactide rod (SR-PLLA) implantation, rigid fixation (K-wire) and non-implantation with posterior interlaminar fusion were compared using a rabbit model. Twenty-four mature domestic rabbits were divided into three groups. Eight received implantation with SR-PLLA, eight with K-wire, and eight were fused without instrumentation. The animals were killed at 12 weeks and evaluated by posteroanterior radiography, manual palpation and histological examination for the presence of fusion. Successful fusion was achieved in all of the animals in both implanted groups (SR-PLLA and K-wire), whereas solid fusion was not detected in any of the specimens in the non-implanted group. Computed tomography (CT) scans were used to detect fusion mass volume. The fusion mass in the SR-PLLA implanted group had a mean volume of 1,196 mm(3)+/- 167 mm(3) vs 1,061 mm(3)+/- 181 mm(3) for the K-wire implanted group (not significant) and 711 mm(3 +/-)407 mm(3) (p < 0.05) for the non-implanted group. The results of this study suggest that the stabilization properties of both SR-PLLA rods and K-wire seem to be sufficient for spinal fusion, but using SR-PLLA is especially advantageous, since they do not require a removal operation and do not interfere with magnetic resonance imaging (MRI).
引用
收藏
页码:227 / 233
页数:7
相关论文
共 33 条
[1]  
Alexander JT, 2002, ORTHOPEDICS, V25, pS1185
[2]  
Ames CP, 2002, ORTHOPEDICS, V25, pS1149
[3]   The use of an osteoinductive growth factor for lumbar spinal fusion .1. Biology of spinal fusion [J].
Boden, SD ;
Schimandle, JH ;
Hutton, WC ;
Chen, MI .
SPINE, 1995, 20 (24) :2626-2632
[4]   The use of coralline hydroxyapatite with bone marrow, autogenous bone graft, or osteoinductive bone protein extract for posterolateral lumbar spine fusion [J].
Boden, SD ;
Martin, GJ ;
Morone, M ;
Ugbo, JL ;
Titus, L ;
Hutton, WC .
SPINE, 1999, 24 (04) :320-327
[5]   DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES [J].
BOSTMAN, O ;
PAIVARINTA, U ;
PARTIO, E ;
VASENIUS, J ;
MANNINEN, M ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1021-1031
[6]   Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation:: a review [J].
Böstman, O ;
Pihlajamäki, H .
BIOMATERIALS, 2000, 21 (24) :2615-2621
[7]   TRANSPHYSEAL FRACTURE FIXATION USING BIODEGRADABLE PINS [J].
BOSTMAN, O ;
MAKELA, EA ;
TORMALA, P ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (04) :706-707
[8]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[9]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[10]   FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324