Application of Principal Component Analysis and Fuzzy C-Means Clustering Algorithm to the Classification of UHMWPE Wear Debris from Artificial Joints

被引:0
作者
Wu, J. P. [1 ]
Yan, X. P. [1 ]
Yuan, C. Q. [1 ]
Zhou, X. C. [1 ]
Jin, Z. [2 ]
Tipper, J. L. [2 ]
机构
[1] Wuhan Univ Technol, Reliabil Engn Inst, Wuhan 430063, Hubei, Peoples R China
[2] Univ Leeds, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
来源
ADVANCED TRIBOLOGY | 2009年
关键词
UHMWPE Wear debris; Artificial joints; Principal Component Analysis; Fuzzy C-Means Clustering Algorithm; POLYETHYLENE; REPLACEMENTS;
D O I
10.1007/978-3-642-03653-8_286
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The application of principal component analysis and fuzzy C-means clustering algorithm to the classification of UHMWPE wear debris from artificial joints has been described. Wear particles were extracted and isolated from periprosthetic tissues collected during revision surgery, of which was revised for loosening. The implant life of the patient was 12 years. The particles were examined by scanning electron microscopy. Digitized particle images were analyzed on a computer by specially developed software 'Image-Pro Plus'. The following nineteen numerical descriptors were used to characterize the particles: particle area, length, width, perimeter, boundary fractal dimension and shape parameters such as form factor, roundness, convexity, aspect ratio et al. Principal component analysis algorithm was applied to reduced the amount of the parameters in order to simplify the following calculation. Furthermore, main factors and important parameters such as mean diameter, ECD and perimeter were found out. However, C-means clustering algorithm was applied to classify the UHMWPE wear debris into four to seven clusters. Xie-Beni index was introduced to determine the optimal number of cluster and illuminate the clustering validity. The result of the calculation indicates that five clusters is the optimal clustering number. The feature of the debris in each cluster was also described in this paper.
引用
收藏
页码:855 / +
页数:2
相关论文
共 7 条
  • [1] Failure analysis on retrieved ultra high molecular weight polyethylene (UHMWPE) acetabular cups
    Burger, N. D. L.
    de Vaal, P. L.
    Meyer, J. P.
    [J]. ENGINEERING FAILURE ANALYSIS, 2007, 14 (07) : 1329 - 1345
  • [2] Effects of clinically relevant alumina ceramic wear particles on TNF-α production by human peripheral blood mononuclear phagocytes
    Hatton, A
    Nevelos, JE
    Matthews, JB
    Fisher, J
    Ingham, E
    [J]. BIOMATERIALS, 2003, 24 (07) : 1193 - 1204
  • [3] The size and shape of particulate polyethylene wear debris in total joint replacements
    Kobayashi, A
    Bonfield, W
    Kadoya, Y
    Yamac, T
    Freeman, MAR
    Scott, G
    Revell, PA
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) : 11 - 15
  • [4] SAVIO JA, 1993, CLINMATER, V12, P1247
  • [5] Isolation, characterization and quantification of polyethylene wear debris from periprosthetic tissues around total joint replacements
    Slouf, Miroslav
    Eklova, Simona
    Kumstatova, Jitka
    Berger, Stephane
    Synkova, Hana
    Sosna, Antonin
    Pokorny, David
    Spundova, Marcela
    Entlicher, Gustav
    [J]. WEAR, 2007, 262 (9-10) : 1171 - 1181
  • [6] Tipper JL, 1999, J MATER SCI-MATER M, V11, P117
  • [7] ZHAO H, 2007, SYSTEMS ENG ELECT, P96