A Non-Invasive Sound Technology to Monitor Rumen Contractions

被引:2
|
作者
Vargas-Bello-Perez, Einar [1 ,2 ]
Neves, Andre Luis Alves [2 ]
Harrison, Adrian [3 ]
机构
[1] Univ Reading, Sch Agr Policy & Dev, Dept Anim Sci, POB 237, Reading RG6 6EU, Berks, England
[2] Univ Copenhagen, Dept Vet & Anim Sci, Prod Nutr & Hlth, Gronnegardsvej 3, DK-1870 Frederiksberg C, Denmark
[3] Univ Copenhagen, Fac Hlth & Med Sci, Dept Vet & Anim Sci IVH, Sect Physiol,PAS, Dyrlaegevej 100, DK-1870 Frederiksberg C, Denmark
来源
ANIMALS | 2022年 / 12卷 / 17期
关键词
cows; acoustic; rumen sounds; enteric gas; contractions; rumen movements; RUMINATION ACTIVITY;
D O I
10.3390/ani12172164
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary The recording of rumen sounds can be an important tool to assess the health status of a herd, as the frequency and amplitude of rumen contractions are associated with the flow and fermentation patterns of feed particles in the ruminoreticulum compartment. In this technical report, using a wireless device (CURO MkII), we recorded high-quality rumen sound waves that differentiate rumen contractions between cows of different production statuses (dry cow vs. lactating cow) and physiological stages (pregnant vs. non-pregnant). We envision that the rumen sound recordings will be a new form of technology to detect the onset of metabolic diseases, such as acidosis and hypocalcemia, which usually cause changes in the physicochemical properties of the rumen environment and reduce the frequency of rumen contractions. However, this technology still needs further improvement and validation through recordings of rumen movements in animals experiencing metabolic diseases, which will enable early detection of the problem and reduce treatment costs and production losses. This technical report used a wireless device (CURO MkII) that recorded high-quality rumen sound waves from cows of different production statuses (dry cow vs. lactating cow) and physiological stages (pregnant vs. non-pregnant). Recordings from a dry Jersey heifer fed a diet based on haylage and straw showed a few high-amplitude spikes (3 at 6 dB) but mostly infrequent signals (9 at 12 dB and 22 at 18 dB), with pauses of approx. 2 min with no rumen sounds in between. Analysis of a few individual spikes in the 12 dB range showed that wave frequencies ranged from 230 to 250 Hz and lasted 4 s. Recordings of the high-yielding Red Danish cow fed a total mixed ration (TMR) showed an almost constant frequency of the rumen sounds with considerable amplitude of the waves. Rumen sounds from the Red Danish dry and pregnant cow fed on TMR were less frequent, with a lower amplitude than those from the high-yielding cow. These preliminary results demonstrate that wireless sound recording units are capable of measuring rumen sounds in a production setting and can discern between animals of different production and physiological stages, but more studies are needed to confirm our findings.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] NON-INVASIVE VENTILATORY VOLUME MONITOR
    ITOH, A
    ISHIDA, A
    KIKUCHI, N
    OKAZAKI, N
    ISHIHARA, T
    KIRA, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1982, 20 (05) : 613 - 619
  • [2] A non-invasive airborne wave monitor
    Nichols, A.
    Tait, S.
    Horoshenkov, K.
    Shepherd, S.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 34 : 118 - 126
  • [3] Setback for non-invasive glucose monitor
    Owen, VM
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (09): : R1 - R2
  • [4] Fluorescence imaging as a non-invasive technology to monitor the performance of glyphosate adjuvants and formulations
    De Ruiter, H.
    Mack, B.
    Van Der Schoor, R.
    Jalink, H.
    Journal of ASTM International, 2007, 4 (09):
  • [5] Fluorescence imaging as a non-invasive technology to monitor the performance of glyphosate adjuvants and formulations
    de Ruiter, H.
    Mack, B.
    van der Schoor, R.
    Jalink, H.
    PESTICIDE FORMULATIONS AND DELIVERY SYSTEMS, 27TH VOLUME: TRADITIONAL AND NON-TRADITIONAL DEVELOPMENTS, 2008, 1500 : 87 - +
  • [6] The Nexfin Monitor - A Totally Non-Invasive Cardiac Output Monitor
    Perel, Azriel
    Wesselink, Wilbert
    Settels, Jos
    ANAESTHESIA, PHARMACOLOGY, INTENSIVE CARE AND EMERGENCY MEDICINE, A P I C E 2010, 2011, : 103 - 108
  • [7] Non-invasive cardiac output (NICO) monitor
    Sutton, D
    ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (01) : 81 - 81
  • [8] Search for a non-invasive cardiac output monitor
    Thom, Ogilvie
    EMERGENCY MEDICINE AUSTRALASIA, 2008, 20 (03) : 199 - 200
  • [9] A NON-INVASIVE FLOW MONITOR FOR METAL PIPELINES
    HARRISON, A
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (11): : 1266 - 1269
  • [10] In vitro testing of a non-invasive glucose monitor
    Farinas, KC
    Wei, C
    Tamada, JA
    Tierney, MJ
    Berner, B
    Potts, RO
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 344 - PMSE