Application of ion-exclusion/cation-exchange chromatography to water quality monitoring of sub-urban river

被引:6
|
作者
Kozaki, Daislike [1 ]
Goto, Ryozo [1 ]
Masuda, Wakako [1 ]
Saito, Daisuke [1 ]
Nakatani, Nobutake [1 ]
Nakagoshi, Nobukazu [1 ]
Mori, Masanobu [2 ]
Tanaka, Kazuhiko [1 ]
机构
[1] Hiroshima Univ, Grad Sch Int Dev & Cooperat, Higashihiroshima, Hiroshima 7398529, Japan
[2] Gunma Univ, Grad Sch Engn, Kiryu, Gunma 3768515, Japan
关键词
simultaneous ion-exclusion/cation-exchange chromatographic determination; weakly acidic cation-exchange resin; water quality monitoring; sub-urban river watershed; activated sludge process water;
D O I
10.2116/bunsekikagaku.57.651
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A non-suppressed ion-exclusion/cation-exchange chromatography with conductimetric detection for the simultaneous determination of anions (SO42-, Cl-, NO3-, I-, F-, HCOO- and CH3COO-) and cations (Na+, K+, NH4+, Mg2+ and Ca2+) commonly found in a typical suburban river water and discharged water biologically treated by an activated sludge process for urban sewage was studied on a polymethacrylate-based weakly acidic cation-exchange resin column and a mixed eluent consisting Of succinic acid, tartaric acids, and 18-crown-6 at pH 2.9. The separation mechanism is based on the ion-exclusion effect for the anions and the cation-exchange effect for the cations. Under the optimized eluent conditions (26 mM succinic acid/4 mM tartaric acid/1 mM 18-crown-6 at 0.6 mL/min), the simultaneous separation of anions and cations was achieved in ca. 20 min. The analytical performances, including calibration graph, detection limit, reproducibility, and recovery tests, were evaluated under the optimized chromatographic conditions. This simple and convenient non-suppressed ion-exclusion/cation-exchange chromatographic Method Could be successfully applied for evaluating the water quality Of a sub-urban river watershed including sewage treated water, in terms of the biological oxidation reaction of NH4+ to NO3-.
引用
收藏
页码:651 / 658
页数:8
相关论文
共 50 条
  • [31] Ion-exclusion chromatography of silicate ion in sea and river water samples by an ion-exchange enhancement of conductivity detection
    Mori, M
    Tanaka, K
    Taoda, H
    Ikedo, M
    Hu, WZ
    BUNSEKI KAGAKU, 2004, 53 (12) : 1481 - 1486
  • [32] Simultaneous Determinations of Cr(VI) and Cr(III) by Ion-Exclusion/Cation-Exchange Chromatography with an Unmodified Silica-Gel Column
    Hirata, Shizuko
    Kozaki, Daisuke
    Sakanishi, Kinya
    Nakagoshi, Nobukazu
    Tanaka, Kazuhiko
    ANALYTICAL SCIENCES, 2010, 26 (03) : 387 - 390
  • [33] Polydiphenylamine-dodecyl sulfate films for the simultaneous amperometric determination of electroinactive anions and cations in ion-exclusion cation-exchange chromatography
    Qun Xu
    Chun Xu
    Yanping Wang
    Wen Zhang
    Litong Jin
    Kazuhiko Tanaka
    Hiroki Haraguchi
    Akihide Itoh
    Fresenius' Journal of Analytical Chemistry, 2000, 368 : 791 - 796
  • [34] Polydiphenylamine-dodecyl sulfate films for the simultaneous amperometric determination of electroinactive anions and cations in ion-exclusion cation-exchange chromatography
    Xu, Q
    Xu, C
    Wang, YP
    Zhang, W
    Jin, LT
    Tanaka, K
    Haraguchi, H
    Itoh, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 368 (08): : 791 - 796
  • [35] Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent
    Kozaki, Daisuke
    Nakatani, Nobutake
    Mori, Masanobu
    Nakagoshi, Nobukazu
    Tanaka, Kazuhiko
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (07) : 721 - 727
  • [36] Single injection ion-exclusion/cation-exchange chromatography for simultaneous determination of organic/inorganic anions, inorganic cations, and ethanol in beer samples
    Kozaki, Daisuke
    Tanihata, Souma
    Yamamoto, Atsushi
    Nakatani, Nobutake
    Mori, Masanobu
    Tanaka, Kazuhiko
    FOOD CHEMISTRY, 2019, 274 : 679 - 685
  • [37] Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent
    Ohta, K
    Ohashi, M
    Jin, JY
    Takeuchi, T
    Fujimoto, C
    Choi, SH
    Ryoo, JJ
    Lee, KP
    JOURNAL OF CHROMATOGRAPHY A, 2003, 997 (1-2) : 117 - 125
  • [38] Acid rain monitoring by ion-exclusion-cation-exchange chromatography
    Tanaka, K
    Haddad, PR
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (07) : 266 - 273
  • [39] PEAK ENHANCEMENT OF CARBOXYLIC-ACIDS IN ION-EXCLUSION CHROMATOGRAPHY WITH A CATION-EXCHANGE HOLLOW-FIBRE SUPPRESSOR USING NEUTRAL AND ALKALINE ENHANCERS
    MURAYAMA, T
    KUBOTA, T
    HANAOKA, Y
    ROKUSHIKA, S
    KIHARA, K
    HATANO, H
    JOURNAL OF CHROMATOGRAPHY, 1988, 435 (03): : 417 - 424
  • [40] Ion-exclusion chromatography with conductimetric detection of aliphatic carboxylic acids on a weakly acidic cation-exchange resin by elution with benzoic acid-β-cyclodextrin
    Tanaka, K
    Mori, M
    Xu, Q
    Helaleh, MIH
    Ikedo, M
    Taoda, H
    Hu, WZ
    Hasebe, K
    Fritz, JS
    Haddad, PR