A Fluorescence-Based Wireless Capsule Endoscopy System for Detecting Colorectal Cancer

被引:18
作者
Alam, Mohammad Wajih [1 ]
Vedaei, Seyed Shahim [1 ]
Wahid, Khan A. [1 ]
机构
[1] Univ Saskatchewan, Dept Elect & Comp Engn, Saskatoon, SK S7N 5A9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
wireless capsule endoscopy; fluorescence; colorectal cancer; non-invasive; PILLCAM COLON CAPSULE; FEASIBILITY; DIAGNOSIS; RESECTION; ACCURACY;
D O I
10.3390/cancers12040890
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Wireless capsule endoscopy (WCE) has been widely used in gastrointestinal (GI) diagnosis that allows the physicians to examine the interior wall of the human GI tract through a pain-free procedure. However, there are still several limitations of the technology, which limits its functionality, ultimately limiting its wide acceptance. Its counterpart, the wired endoscopic system is a painful procedure that demotivates patients from going through the procedure, and adversely affects early diagnosis. Furthermore, the current generation of capsules is unable to automate the detection of abnormality. As a result, physicians are required to spend longer hours to examine each image from the endoscopic capsule for abnormalities, which makes this technology tiresome and error-prone. Early detection of cancer is important to improve the survival rate in patients with colorectal cancer. Hence, a fluorescence-imaging-based endoscopic capsule that automates the detection process of colorectal cancer was designed and developed in our lab. The proof of concept of this endoscopic capsule was tested on porcine intestine and liquid phantom. The proposed WCE system offers great possibilities for future applicability in selective and specific detection of other fluorescently labelled cancers.
引用
收藏
页数:18
相关论文
共 72 条
[1]   No significant difference in clinically relevant findings between Pillcam® SB3 and Pillcam® SB2 capsules in a United States veteran population [J].
Aasen, Tyler D. ;
Wilhoite, David ;
Rahman, Aynur ;
Devani, Kalpit ;
Young, Mark ;
Swenson, James .
WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY, 2019, 11 (02) :124-132
[2]   Fluorescein-Guided Surgery for Resection of High-Grade Gliomas: A Multicentric Prospective Phase II Study (FLUOGLIO) [J].
Acerbi, Francesco ;
Broggi, Morgan ;
Schebesch, Karl-Michael ;
Hoehne, Julius ;
Cavallo, Claudio ;
De Laurentis, Camilla ;
Eoli, Marica ;
Anghileri, Elena ;
Servida, Maura ;
Boffano, Carlo ;
Pollo, Bianca ;
Schiariti, Marco ;
Visintini, Sergio ;
Montomoli, Cristina ;
Bosio, Lorenzo ;
La Corte, Emanuele ;
Broggi, Giovanni ;
Brawanski, Alexander ;
Ferroli, Paolo .
CLINICAL CANCER RESEARCH, 2018, 24 (01) :52-61
[3]   Design and Implementation of a Wireless Capsule Suitable for Autofluorescence Intensity Detection in Biological Tissues [J].
Al-Rawhani, Mohammed A. ;
Chitnis, Danial ;
Beeley, James ;
Collins, Steve ;
Cumming, David R. S. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (01) :55-62
[4]   A Low-Cost and Portable Smart Instrumentation for Detecting Colorectal Cancer Cells [J].
Alam, Mohammad Wajih ;
Wahid, Khan A. ;
Islam, Md. Fahmid ;
Bernhard, Wendy ;
Geyer, Clarence R. ;
Vizeacoumar, Franco J. .
APPLIED SCIENCES-BASEL, 2019, 9 (17)
[5]   Development of a low-cost and portable smart fluorometer for detecting breast cancer cells [J].
Alam, Mohammad Wajih ;
Wahid, Khan A. ;
Goel, Raghuveera Kumar ;
Lukong, Kiven Erique .
BIOMEDICAL OPTICS EXPRESS, 2019, 10 (02) :399-410
[6]   Are Current Advances of Compression Algorithms for Capsule Endoscopy Enough? A Technical Review [J].
Alam M.W. ;
Hasan M.M. ;
Mohammed S.K. ;
Deeba F. ;
Wahid K.A. .
IEEE Reviews in Biomedical Engineering, 2017, 10 :26-43
[7]  
[Anonymous], PILLCAMTM COLON 2 SY
[8]  
[Anonymous], PHIL RESP
[9]  
[Anonymous], EARL DIAGN SCREEN
[10]  
[Anonymous], COL CANC STAT