Single Cell Microwave Biosensor for Monitoring Cellular Response to Electrochemotherapy

被引:12
作者
Tamra, Amar [1 ,2 ,3 ]
Zedek, Amel [1 ,4 ]
Rols, Marie-Pierre [2 ]
Dubuc, David [1 ]
Grenier, Katia [1 ]
机构
[1] Natl Sci Res Ctr, Lab Anal & Architecture Syst, F-31031 Toulouse, France
[2] Inst Pharmacol & Struct Biol, F-31077 Toulouse, France
[3] King Abdullah Univ Sci & Technol, Thuwal, Saudi Arabia
[4] Landways Management, London, England
关键词
Microwave measurement; Spectroscopy; Cells (biology); Microwave theory and techniques; Biology; Dielectric measurement; Frequency measurement; Biosensor; electrochemotherapy; microwave dielectric spectroscopy; single Cell; THP-1; cells; ON-CHIP ELECTROPORATION; IMPEDANCE SPECTROSCOPY; BLEOMYCIN; ELECTROPERMEABILIZATION; PERSPECTIVES; DELIVERY; ARRAYS; DRUG;
D O I
10.1109/TBME.2022.3170267
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a 40 GHz microwave biosensor used to monitor and characterize single cells (THP-1) subjected to electrochemotherapy and obtain an electronic signature of the treatment efficiency. This biosensor proposes a non-destructive and label-free technique that first allows, with the rapid measurement of single untreated cells in their culture medium, the extraction of two frequency-dependent dielectric parameters, the capacitance (C (f)) and the conductance (G (f)). Second, this technique can powerfully reveal the effects of a chemical membrane permeabilizing treatment (Saponin). At last, it permits us to detect, and predict, the potentiation of a molecule classically used in chemotherapy (Bleomycin) when combined with the application of electric pulses (principle of electrochemotherapy). Treatment-affected cells show a decrease in the capacitive and conductive contrasts, indicating damages at the cellular levels. Along with these results, classical biological tests are conducted. Statistical analysis points out a high correlation rate (R-2>0.97), which clearly reveals the reliability and efficacy of our technique and makes it an attractive technique for biology related researches and personalized medicine.
引用
收藏
页码:3407 / 3414
页数:8
相关论文
共 50 条
[21]   Integrated Biosensor System for Monitoring and Visualizing Fish Stress Response [J].
Wu, Haiyun ;
Murata, Masataka ;
Matsumoto, Haruto ;
Ohnuki, Hitoshi ;
Endo, Hideaki .
SENSORS AND MATERIALS, 2020, 32 (12) :4095-4110
[22]   Increasing operating frequency band of cytometric biosensor for single cell impedance characterization [J].
Claudel, J. ;
De Araujo, A. Alves ;
Nadi, M. ;
Kourtiche, D. .
2018 12TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2018, :324-329
[23]   Determining the Dose-Response Curve of Exoelectrogens: A Microscale Microbial Fuel Cell Biosensor for Water Toxicity Monitoring [J].
Fei, Sitao ;
Ren, Hao .
MICROMACHINES, 2022, 13 (10)
[24]   Impedance based biosensor array for monitoring mammalian cell behavior [J].
Huang, X ;
Greve, DW ;
Nguyen, DD ;
Domach, MM .
PROCEEDINGS OF THE IEEE SENSORS 2003, VOLS 1 AND 2, 2003, :304-309
[25]   Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform [J].
Kim, Jayoung ;
Sempionatto, Juliane R. ;
Imani, Somayeh ;
Hartel, Martin C. ;
Barfidokht, Abbas ;
Tang, Guangda ;
Campbell, Alan S. ;
Mercier, Patrick P. ;
Wang, Joseph .
ADVANCED SCIENCE, 2018, 5 (10)
[26]   MONITORING GLUTAMINE IN MAMMALIAN-CELL CULTURES USING AN AMPEROMETRIC BIOSENSOR [J].
CATTANEO, MV ;
LUONG, JHT ;
MERCILLE, S .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (05) :329-334
[27]   Mobile biosensor for water quality monitoring Detection of oil in biotope water with a whole-cell biosensor system [J].
Staudacher, P. ;
Wolf, B. ;
Schmidhuber, M. ;
Wiest, J. .
IEEE AFRICON 2011, 2011,
[28]   A WIRELESS MEMS MICROBIAL FUEL CELL BIOSENSOR WITH RECORD ULTRA-SHORT RESPONSE TIME FOR COPPER ION IN WATER MONITORING [J].
Wang, Yining ;
Tang, Fengxiang ;
Zhang, Ruohan ;
Wu, Yifan ;
Ren, Hao .
2024 IEEE 37TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2024, :284-287
[29]   Real-time monitoring of intracellular biochemical response in locally stretched single cell by a nanosensor [J].
Jin, Xue-Ke ;
Jin, Kai-Qi ;
Yang, Xiao-Ke ;
Wen, Ming-Yong ;
Liu, Yan-Ling ;
Huang, Wei-Hua .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (21) :4779-4787
[30]   Ultra sensitive biosensor based on impedance spectroscopy at microwave frequencies for cell scale analysis [J].
Dalmay, C. ;
Cheray, M. ;
Pothier, A. ;
Lalloue, F. ;
Jauberteau, M. O. ;
Blondy, P. .
SENSORS AND ACTUATORS A-PHYSICAL, 2010, 162 (02) :189-197