Detection of cancer with graphene metasurface-based highly efficient sensors

被引:69
作者
Patel, Shobhit K. [1 ]
Surve, Jaymit [2 ]
Parmar, Juveriya [3 ]
机构
[1] Marwadi Univ, Dept Comp Engn, Rajkot, Gujarat, India
[2] Marwadi Univ, Dept Elect Engn, Rajkot, Gujarat, India
[3] Univ Nebraska Lincoln, Dept Mech & Mat Engn, 1400 R St, Lincoln, NE 68588 USA
关键词
Cancer detection; Graphene; Metasurface; Sensors; Blood cancer; Skin cancer; Adrenal cancer; Breast cancer; Cervical cancer; GLOBAL BURDEN; BIOSENSOR; METAMATERIAL; CARE;
D O I
10.1016/j.diamond.2022.109367
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We have proposed several four metasurface sensor designs that include metasurface design with no gaps (MSDG), metasurface design with outer gaps (MSDG1), metasurface design with inner gaps (MSDG2), and metasurface design with inner and outer gaps (MSDG3) for the detection of several types of cancer affected cells. There are significant differences in optical properties between cancer-contaminated cells and their normal counterparts when the refractive indices of the two cell types are compared. A liquid's concentration of malignant cells is estimated at 80 %. The structure parameters are varied to obtain the optimal design. The sensors are investigated for several parameters including absolute and relative sensitivities, Quality factor (Q factor), a figure of merit (FOM), detection limit, etc. For each structure designs highest sensitivities of 66.67 GHz/RIU, 66.67 GHz/RIU, 200 GHz/RIU, and 207.14 GHz/RIU are achieved in terms of both absolute sensitivity and relative sensitivity. The Q factor and FOM of 13.11 and 3.86 RIU-1 are attained, respectively and the lowest detection limit of 0.17 RIU is obtained for the optimal design of MSDG3.
引用
收藏
页数:9
相关论文
共 54 条
  • [1] Highly sensitive Au-Fe2O3-Au and Fe2O3-Au-Fe2O3 biosensors utilizing strong surface plasmon resonance
    Ahmed, Ashour M.
    Shaban, Mohamed
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (04):
  • [2] Numerical demonstration of triangular shaped photonic crystal fibre-based biosensor in the Terahertz range
    Ahmed, Kawsar
    Paul, Bikash Kumar
    Ahmed, Fahad
    Jabin, Md. Asaduzzaman
    Uddin, Muhammad Shahin
    [J]. IET OPTOELECTRONICS, 2021, 15 (01) : 1 - 7
  • [3] COMSOL, MULT V 6 0
  • [4] Global burden of cancer attributable to infections in 2018: a worldwide incidence analysis
    de Martel, Catherine
    Georges, Damien
    Bray, Freddie
    Ferlay, Jacques
    Clifford, Gary M.
    [J]. LANCET GLOBAL HEALTH, 2020, 8 (02): : E180 - E190
  • [5] International Variation in Female Breast Cancer Incidence and Mortality Rates
    DeSantis, Carol E.
    Bray, Freddie
    Ferlay, Jacques
    Lortet-Tieulent, Joannie
    Anderson, Benjamin O.
    Jemal, Ahmedin
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2015, 24 (10) : 1495 - 1506
  • [6] Ferlay J, 2019, Cancer Today
  • [7] A Route to Terahertz Metamaterial Biosensor Integrated with Microfluidics for Liver Cancer Biomarker Testing in Early Stage
    Geng, Zhaoxin
    Zhang, Xiong
    Fan, Zhiyuan
    Lv, Xiaoqing
    Chen, Hongda
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [8] Dyadic Green's functions and guided surface waves for a surface conductivity model of graphene
    Hanson, George W.
    [J]. JOURNAL OF APPLIED PHYSICS, 2008, 103 (06)
  • [9] Graphene-based potentiometric biosensor for the immediate detection of living bacteria
    Hernandez, Rafael
    Valles, Cristina
    Benito, Ana M.
    Maser, Wolfgang K.
    Xavier Rius, F.
    Riu, Jordi
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 54 : 553 - 557
  • [10] Numerical Simulation of Tunable Terahertz Graphene-Based Sensor for Breast Tumor Detection
    Hlali, Aymen
    Oueslati, Afef
    Zairi, Hassen
    [J]. IEEE SENSORS JOURNAL, 2021, 21 (08) : 9844 - 9851