Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm

被引:0
作者
Navab, N
Mitschke, M
Schütz, O
机构
[1] Siemens Corp Res, Princeton, NJ 08540 USA
[2] Siemens AG, Med Engn, D-91052 Erlangen, Germany
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS | 1999年 / 1679卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
High-end X-ray C-arm gantries have recently been used for 3D reconstruction. Low-cost mobile C-arms enjoy the advantage of being readily available and are often used as interventional imaging device, but do not guarantee the reproducibility of their motion. The calibration and reconstruction process used for high-end C-arms cannot be applied to them. Camera-Augmented Mobile C-arm (CAMC) is the solution we propose. A CCD camera is attached to the (motorized) mobile C-arm in order to calibrate the C-arm's projection geometry on-line. The relationship between X-ray and camera projection geometry is characterized in an off-line calibration process. We propose the notion of Virtual Detector (VD), which enables us to describe both optical and X-ray geometry as pinhole cameras with fixed intrinsic parameters. We have conducted experiments in order to compare the results of CAMC calibration with the calibration method used for high-end C-arms and using an optical tracking system (Polaris from Northern Digital, Inc.).
引用
收藏
页码:688 / 697
页数:10
相关论文
共 50 条
  • [21] 3D imaging with an isocentric mobile C-arm - Comparison of image quality with spiral CT
    Kotsianos, D
    Wirth, S
    Fischer, T
    Euler, E
    Rock, C
    Linsenmaier, U
    Pfeifer, KJ
    Reiser, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (09) : 1590 - 1595
  • [22] Low contrast 3D-reconstruction from C-arm data
    Zellerhoff, M
    Scholz, B
    Rührnschopf, EP
    Brunner, T
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 646 - 655
  • [23] Intraoperative 3D imaging with a standard c-arm
    Tita, R.
    Lueth, T. C.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S206 - S208
  • [24] A cheap and easy method for 3D C-arm reconstruction using elliptic curves
    Burkhardt, David
    Jain, Ameet
    Fichtinger, Gabor
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [25] Online geometrical calibration of a mobile C-arm using external sensors
    Mitschke, MM
    Navab, N
    Schütz, O
    [J]. MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION, 2000, 3976 : 580 - 587
  • [26] TV-regularized Iterative Image Reconstruction on a Mobile C-ARM CT
    Pan, Yongsheng
    Whitaker, Ross
    Cheryauka, Arvi
    Ferguson, Dave
    [J]. MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [27] Hardware-accelerated cone-beam reconstruction on a mobile C-arm
    Churchill, Michael
    [J]. Medical Imaging 2007: Physics of Medical Imaging, Pts 1-3, 2007, 6510 : U2193 - U2200
  • [28] Single-step localization and excision of small pulmonary nodules using a mobile 3D C-arm
    Hsieh, Ming-Ju
    Chou, Pin-Li
    Fang, Hsin-Yueh
    Wen, Chih-Tsung
    Chao, Yin-Kai
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (06) : 885 - 891
  • [29] 3-D geometry calibration and markerless electromagnetic tracking with a mobile C-arm
    Cheryauka, Arvi
    Barrett, Johnny
    Wang, Zhonghua
    Litvin, Andrew
    Hamadeh, Ali
    Beaudet, Daniel
    [J]. MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [30] Modelling the acquisition geometry of a C-arm angiography system for 3D reconstruction
    Cañero, C
    Nofrerías, E
    Mauri, J
    Radeva, P
    [J]. TOPICS IN ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2002, 2504 : 322 - 335