A Contactless Respiratory Rate Estimation Method Using a Hermite Magnification Technique and Convolutional Neural Networks

被引:29
作者
Brieva, Jorge [1 ]
Ponce, Hiram [1 ]
Moya-Albor, Ernesto [1 ]
机构
[1] Univ Panamericana, Fac Ingn, Augusto Rodin 498, Mexico City 03920, DF, Mexico
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 02期
关键词
respiratory rate estimation; non-contact monitoring; motion video magnification; hermite transform; IMAGE; SIGNS;
D O I
10.3390/app10020607
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The monitoring of respiratory rate is a relevant factor in medical applications and day-to-day activities. Contact sensors have been used mostly as a direct solution and they have shown their effectiveness, but with some disadvantages for example in vulnerable skins such as burns patients. For this reason, contactless monitoring systems are gaining increasing attention for respiratory detection. In this paper, we present a new non-contact strategy to estimate respiratory rate based on Eulerian motion video magnification technique using Hermite transform and a system based on a Convolutional Neural Network (CNN). The system tracks chest movements of the subject using two strategies: using a manually selected ROI and without the selection of a ROI in the image frame. The system is based on the classifications of the frames as an inhalation or exhalation using CNN. Our proposal has been tested on 10 healthy subjects in different positions. To compare performance of methods to detect respiratory rate the mean average error and a Bland and Altman analysis is used to investigate the agreement of the methods. The mean average error for the automatic strategy is 3.28 +/- 3.33% with and agreement with respect of the reference of approximate to 98%.
引用
收藏
页数:20
相关论文
共 41 条
[1]   Simultaneous tracking of cardiorespiratory signals for multiple persons using a machine vision system with noise artifact removal [J].
Al-Naji, Ali ;
Chahl, Javaan .
IEEE Journal of Translational Engineering in Health and Medicine, 2017, 5
[2]   Monitoring of Cardiorespiratory Signal: Principles of Remote Measurements and Review of Methods [J].
Al-Naji, Ali ;
Gibson, Kim ;
Lee, Sang-Heon ;
Chahl, Javaan .
IEEE ACCESS, 2017, 5 :15776-15790
[3]   Remote sensing of physiological signs using a machine vision system [J].
Al-Naji, Ali ;
Gibson, Kim ;
Chahl, Javaan .
Journal of Medical Engineering and Technology, 2017, 41 (05) :396-405
[4]   Remote respiratory monitoring system based on developing motion magnification technique [J].
Al-Naji, Ali ;
Chahl, Javaan .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 29 :1-10
[5]  
Alam S, 2017, IEEE ENG MED BIO, P4293, DOI 10.1109/EMBC.2017.8037805
[6]  
Alinovi D, 2018, EUR SIGNAL PR CONF, P1780, DOI 10.23919/EUSIPCO.2018.8553066
[7]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[8]   Continuous wavelet filtering on webcam photoplethysmographic signals to remotely assess the instantaneous heart rate [J].
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Pruski, Alain .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) :568-574
[9]  
Brieva J., 2017, MED INF PROCESS ANAL, P10572
[10]  
Brieva J., 2018, OPENAIRE, P10975