Follow-up versus tissue diagnosis in BI-RADS category 3 solid breast lesions at US: a cost-consequence analysis

被引:6
作者
Alimoglu, Emel [1 ]
Bayraktar, Sule Dogan [3 ]
Bozkurt, Selen [2 ]
Ceken, Kagan [1 ]
Kabaalioglu, Adnan [1 ]
Apaydin, Ali [1 ]
Sindel, Hakki Timur [1 ]
机构
[1] Akdeniz Univ, Sch Med, Dept Radiol, TR-07058 Antalya, Turkey
[2] Akdeniz Univ, Sch Med, Dept Biostat & Med Informat, TR-07058 Antalya, Turkey
[3] Antalya Training & Res Hosp, Dept Radiol, Antalya, Turkey
关键词
breast; biopsy; cost analysis; BENIGN; MASSES; BIOPSY; MAMMOGRAPHY; SONOGRAPHY;
D O I
10.4261/1305-3825.DIR.4462-11.1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE The aim of this study was to compare the economic effect of a proposed follow-up strategy for managing category 3 breast masses. The strategy incorporated direct tissue diagnosis at the patient's discretion for masses that had been assessed only based on ultrasonography (US) and for which mammography made no diagnostic contribution. MATERIALS AND METHODS This prospective cohort study was conducted between 2003 and 2006 and included 174 patients. We used a two-year short-term follow-up protocol composed of five steps. A biopsy was recommended for masses that were increasing in size and changing in nature. The long-term results were available at the end of 2010. The mean and total costs were calculated for the women who preferred our follow-up protocol and for those who preferred direct tissue diagnosis. The cost savings were calculated by comparing the costs of the current study protocol to the costs of two different scenarios. RESULTS Two malignancies were found among the 18 women who underwent tissue diagnosis on the recommendation of the radiologist during follow-up. Thirteen of these women underwent biopsy at the request of the patient or surgeon, and these biopsies all revealed benign tumors. The overall negative predictive value was 99.2% (95% confidence interval, 98.46%-100%). There was a statistically significant difference between the mean costs for the women who chose our follow-up regimen (147.57 +/- 106.7 TL) and those who preferred direct tissue diagnosis (426.89 +/- 149.8 TL) (P = 0.0001). The use of our follow-up protocol decreased the cost of diagnosis by 60% compared with the cost of using direct tissue diagnosis as the initial procedure. CONCLUSION Our long-term results indicate that following-up solid category 3 masses detected only by US for at least two years at short intervals is a cost-effective alternative to direct breast biopsy.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 27 条
  • [1] Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision:: Utility and cost study in probably benign lesions
    Alonso-Bartolomé, P
    Vega-Bolívar, A
    Torres-Tabanera, M
    Ortega, E
    Acebal-Blanco, M
    Garijo-Ayensa, F
    Rodrigo, I
    Muñoz-Cacho, P
    [J]. ACTA RADIOLOGICA, 2004, 45 (04) : 390 - 396
  • [2] Reliability and Validity of Psychological General Well-Being Index in Turkish Population
    Ay, Saime
    Koldas Dogan, Sebnem
    Evcik, Deniz
    Gok, Haydar
    Tur, Birkan Sonel
    Gokmen, Derya
    [J]. TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 56 (04): : 161 - 169
  • [3] Supplemental screening sonography in dense breasts
    Berg, WA
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (05) : 845 - +
  • [4] Bertheau P, 1999, SEMIN DIAGN PATHOL, V16, P248
  • [5] Brenner RJ, 1997, ACAD RADIOL, V4, P419
  • [6] Drummond M. F., 2006, SMJ Singapore Medical Journal, V47, P456
  • [7] Guidelines for authors and peer reviewers of economic submissions to the BMJ
    Drummond, MF
    Jefferson, TO
    [J]. BRITISH MEDICAL JOURNAL, 1996, 313 (7052) : 275 - 283
  • [8] Gazete T. C. Resmi, 2006, RESMI GAZETE
  • [9] Solid breast masses diagnosed as fibroadenoma at fine-needle aspiration biopsy: Acceptable rates of growth at long-term follow-up
    Gordon, PB
    Gagnon, FA
    Lanzkowsky, L
    [J]. RADIOLOGY, 2003, 229 (01) : 233 - 238
  • [10] Follow-up of palpable circumscribed noncalcified solid breast masses at mammography and US: Can biopsy be averted?
    Graf, O
    Helbich, TH
    Fuchsjaeger, MH
    Hopf, G
    Morgun, M
    Graf, C
    Mallek, R
    Sickles, EA
    [J]. RADIOLOGY, 2004, 233 (03) : 850 - 856