Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

被引:77
作者
Groen, Jaap M. [1 ]
Greuter, Marcel J. W. [1 ]
Vliegenthart, R. [1 ]
Suess, C. [2 ]
Schmidt, B. [2 ]
Zijlstra, F. [3 ]
Oudkerk, M. [1 ]
机构
[1] Univ Groningen, Med Ctr, Dept Radiol, Groningen, Netherlands
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Groningen, Med Ctr, Dept Cardiol, Groningen, Netherlands
关键词
calcium score; dual source CT; 64-slice MDCT; electron beam CT; heart rate;
D O I
10.1007/s10554-007-9282-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Assessment of calcium scoring (Ca-scoring) on a 64-slice multi-detector computed tomography (MDCT) scanner, a dual-source computed tomography (DSCT) scanner and an electron beam tomography (EBT) scanner with a moving cardiac phantom as a function of heart rate, slice thickness and calcium density. Methods and materials Three artificial arteries with inserted calcifications of different sizes and densities were scanned at rest (0 beats per minute) and at 50-110 beats per minute (bpm) with an interval of 10 bpm using 64-slice MDCT, DSCT and EBT. Images were reconstructed with a slice thickness of 0.6 and 3.0 mm. Agatston score, volume score and equivalent mass score were determined for each artery. A cardiac motion susceptibility (CMS) index was introduced to assess the susceptibility of Ca-scoring to heart rate. In addition, a difference (Delta) index was introduced to assess the difference of absolute Ca-scoring on MDCT and DSCT with EBT. Results Ca-score is relatively constant up to 60 bpm and starts to decrease or increase above 70 bpm, depending on scoring method, calcification density and slice thickness. EBT showed the least susceptibility to cardiac motion with the smallest average CMS-index (2.5). The average CMS-index of 64-slice MDCT (9.0) is approximately 2.5 times the average CMS-index of DSCT (3.6). The use of a smaller slice thickness decreases the CMS-index for both CT-modalities. The Delta-index for DSCT at 0.6 mm (53.2) is approximately 30% lower than the Delta-index for 64-slice MDCT at 0.6 mm (72.0). The Delta-indexes at 3.0 mm are approximately equal for both modalities (96.9 and 102.0 for 64-slice MDCT and DSCT respectively). Conclusion Ca-scoring is influenced by heart rate, slice thickness and modality used. Ca-scoring on DSCT is approximately 50% less susceptible to cardiac motion as 64-slice MDCT. DSCT offers a better approximation of absolute calcium score on EBT than 64-slice MDCT when using a smaller slice thickness. A smaller slice thickness reduces the susceptibility to cardiac motion and reduces the difference between CT-data and EBT-data. The best approximation of EBT on CT is found for DSCT with a slice thickness of 0.6 mm.
引用
收藏
页码:547 / 556
页数:10
相关论文
共 22 条
[1]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]   Impact of motion artefact on the measurement of coronary calcium score [J].
Brown, SJ ;
Hayball, MP ;
Coulden, RAR .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873) :956-962
[4]   Rates of progression of coronary calcium by electron beam tomography [J].
Budoff, MJ ;
Lane, KL ;
Bakhsheshi, H ;
Mao, S ;
Grassmann, BO ;
Friedman, BC ;
Brundage, BH .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (01) :8-11
[5]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[6]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort - Consequences for progression studies [J].
Hoffmann, U ;
Siebert, U ;
Bull-Stewart, A ;
Achenbach, S ;
Ferencik, M ;
Moselewski, F ;
Brady, TJ ;
Massaro, JM ;
O'Donnell, CJ .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :396-402
[9]   Vascular calcification in ex vivo carotid specimens: Precision and accuracy of measurements with multi-detector row CT [J].
Hoffmann, U ;
Kwait, DC ;
Handwerker, J ;
Chan, R ;
Lamuraglia, G ;
Brady, TJ .
RADIOLOGY, 2003, 229 (02) :375-381
[10]   Electron beam CT versus 16-slice spiral CT: how accurately can we measure coronary artery calcium volume? [J].
Horiguchi, J ;
Shen, Y ;
Akiyama, Y ;
Hirai, N ;
Sasaki, K ;
Ishifuro, M ;
Ito, K .
EUROPEAN RADIOLOGY, 2006, 16 (02) :374-380