Dual-Energy Computed Tomography for Stone Type Assessment: A Pilot Study of Dual-Energy Computed Tomography with Five Indices

被引:10
作者
Rudenko, Vadim [1 ]
Serova, Natalia [2 ]
Kapanadze, Lida [2 ]
Taratkin, Mark [1 ,4 ]
Okhunov, Zhamshid [5 ]
Leonard, Stephen P. [6 ]
Ritter, Manuel [7 ]
Kriegmair, Maximilian [8 ]
Snurnitsyna, Olesya [1 ]
Kozlov, Vasiliy [3 ]
Laukhtina, Ekaterina [1 ]
Arshiev, Magomed [9 ]
Aleksandrova, Ksenia [2 ]
Salomon, Georg [4 ,10 ]
Enikeev, Dmitry [1 ]
Glybochko, Petr [1 ]
机构
[1] Sechenov Univ, Inst Urol & Reprod Hlth, 2-1 Bolshaya Pirogovskaya St, Moscow 119991, Russia
[2] Sechenov Univ, Dept Radiol, Moscow, Russia
[3] Sechenov Univ, Dept Publ Hlth & Healthcare Org, Moscow, Russia
[4] EAU Sect Urol Imaging, Amsterdam, Netherlands
[5] Univ Calif Irvine, Dept Urol, Irvine, CA USA
[6] Sechenov Univ, Inst Linguist & Intercultural Commum, Moscow, Russia
[7] Univ Hosp Bonn, Dept Urol, Bonn, Germany
[8] Univ Med Ctr Mannheim, Dept Urol, Mannheim, Germany
[9] Sechenov Univ, Moscow, Russia
[10] Univ Med Ctr Hamburg Eppendorf, Martini Clin, Hamburg, Germany
关键词
urolithiasis; dual-energy CT; stone composition; URIC-ACID; URINARY CALCULI; SOURCE CT; DIFFERENTIATION; PREDICTION; FRAGILITY;
D O I
10.1089/end.2020.0243
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose:To assess the efficacy of dual-energy CT (DECT) in predicting the composition of urinary stones with a single index (dual energy ratio [DER]) and five indices. Methods:Patients undergoing DECT before active urolithiasis treatment were prospectively enrolled in the study. Predictions of stone composition were made based on discriminant analysis with a single index (DER) and five indices (stone density at 80 and 135 kV, Zeff [the effective atomic number of the absorbent material] of the stone, DER, dual-energy index [DEI] and dual-energy difference [DED]). After extraction, stone composition was evaluated by means of physicochemical analyses (X-ray phase analysis, electron microscopy, wet chemistry techniques, and infrared spectroscopy). Results:A total of 91 patients were included. For calcium oxalate monohydrate (COM) stones, the sensitivity, specificity, and overall accuracy of DECT with one index (DER) were 83.3%, 89.8%, and 86.8%, respectively; for calcium oxalate dihydrate (COD) and calcium phosphate stones-88.2%, 92.9%, and 91.2%, respectively; for uric acid stones-0%, 98.8% and 97.8%, respectively; for struvite stones-60%, 95.3%, and 93.4%, respectively. Discriminant analysis with five indices yielded the following sensitivity, specificity, and overall accuracy: 95.2%, 89.8%, and 92.3% for COM stones, 85.3%, 96.4%, and 92.3% for COD stones, and 100% in all three categories for both uric acid and struvite stones. Conclusions:DECT is a promising tool for stone composition assessment. It allowed for evaluation of chemical composition of all stone types with specificity and accuracy ranging from 85% to 100%. Five DECT indices have shown much better diagnostic accuracy compared to a single DECT index.
引用
收藏
页码:893 / 899
页数:7
相关论文
共 26 条
[1]   In vivo characterization of urinary calculi on dual-energy CT: going a step ahead with sub-differentiation of calcium stones [J].
Acharya, Sudeep ;
Goyal, Ankur ;
Bhalla, Ashu Seith ;
Sharma, Raju ;
Seth, Amlesh ;
Gupta, Arun Kumar .
ACTA RADIOLOGICA, 2015, 56 (07) :881-889
[2]   Role of dual-source dual-energy computed tomography versus X-ray crystallography in prediction of the stone composition: a retrospective non-randomized pilot study [J].
Akand, Murat ;
Koplay, Mustafa ;
Islamoglu, Necat ;
Gul, Murat ;
Kilic, Ozcan ;
Erdogdu, Merter Bora .
INTERNATIONAL UROLOGY AND NEPHROLOGY, 2016, 48 (09) :1413-1420
[3]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[4]   Quantitative Prediction of Stone Fragility From Routine Dual Energy CT: Ex vivo proof of Feasibility [J].
Ferrero, Andrea ;
Montoya, Juan C. ;
Vaughan, Lisa E. ;
Huang, Alice E. ;
McKeag, Ian O. ;
Enders, Felicity T. ;
Williams, James C., Jr. ;
McCollough, Cynthia H. .
ACADEMIC RADIOLOGY, 2016, 23 (12) :1545-1552
[5]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[6]   Dual energy CT: preliminary observations and potential clinical applications in the abdomen [J].
Graser, Anno ;
Johnson, Thorsten R. C. ;
Chandarana, Hersh ;
Macari, Michael .
EUROPEAN RADIOLOGY, 2009, 19 (01) :13-23
[7]   Impact of dual energy characterization of urinary calculus on management [J].
Habashy, David ;
Xia, Ryan ;
Ridley, William ;
Chan, Lewis ;
Ridley, Lloyd .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (05) :624-631
[8]   Determination of Renal Stone Composition with Dual-Energy CT: In Vivo Analysis and Comparison with X-ray Diffraction [J].
Hidas, Guy ;
Eliahou, Ruth ;
Duvdevani, Mordechai ;
Coulon, Phillipe ;
Lemaitre, Laurent ;
Gofrit, Ofer N. ;
Pode, Dov ;
Sosna, Jacob .
RADIOLOGY, 2010, 257 (02) :394-401
[9]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[10]   Material differentiation by dual energy CT: initial experience [J].
Johnson, Thorsten R. C. ;
Krauss, Bernhard ;
Sedlmair, Martin ;
Grasruck, Michael ;
Bruder, Herbert ;
Morhard, Dominik ;
Fink, Christian ;
Weckbach, Sabine ;
Lenhard, Miriam ;
Schmidt, Bernhard ;
Flohr, Thomas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .