A low background neutron flux monitor for the n-TOF facility at CERN

被引:94
作者
Marrone, S
Mastinu, PF
Abbondanno, U
Baccomi, R
Marchi, EB
Bustreo, N
Colonna, N
Gramegna, F
Loriggiola, M
Marigo, S
Milazzo, PM
Moreau, C
Sacchetti, M
Tagliente, G
Terlizzi, R
Vannini, G
Aerts, G
Berthomieux, E
Cano-Ott, D
Cennini, P
Domingo-Pardo, C
Ferrant, L
Gonzalez-Romero, E
Gunsing, F
Heil, M
Kaeppler, F
Papaevangelou, T
Paradela, C
Pavlopoulos, P
Perrot, L
Plag, R
Tain, JL
Wendler, H
机构
[1] Univ Bari, Dipartimento Fis, I-70125 Bari, Italy
[2] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Legnaro, Italy
[3] Ist Nazl Fis Nucl, Sezt Trieste, Trieste, Italy
[4] Univ Bologna, Dipartimento Fis, I-40126 Bologna, Italy
[5] Ist Nazl Fis Nucl, Sez Bologna, I-40126 Bologna, Italy
[6] CEA Saclay, DSM, DAPNIA, SPhN, F-91191 Gif Sur Yvette, France
[7] Ctr Invest Energet Medioambientales & Tecnol, Madrid, Spain
[8] CERN, CH-1211 Geneva 23, Switzerland
[9] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46003 Valencia, Spain
[10] CNRS, IPN, IN2P3, Orsay, France
[11] Forschungszentrum Karlsruhe, Inst Kernphys, D-76021 Karlsruhe, Germany
[12] Univ Thessaloniki, GR-54006 Thessaloniki, Greece
[13] Univ Santiago de Compostela, Santiago De Compostela, Spain
[14] Pole Univ Leonard de Vinci, Paris Def, Paris, France
[15] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
关键词
neutron flux; silicon detectors; carbon fibre; Monte Carlo simulations;
D O I
10.1016/j.nima.2003.09.060
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A small-mass system has been developed for monitoring the flux of neutrons with energy up to 1 MeV at the new time-of-flight facility at CERN, n(-)TOF. The monitor is based on a thin Mylar foil with a Li-6 deposit, placed in the neutron beam, and an array of silicon detectors, placed outside the beam, for detecting the products of the Li-6(n, alpha)H-3 reaction. The small amount of material on the beam ensures a minimal perturbation of the flux and minimizes the background related to scattered neutrons. Moreover, a further reduction of the gamma-ray background has been obtained by constructing the scattering chamber hosting the device in carbon fibre. A detailed description of the flux monitor is here presented, together with the characteristics of the device, in terms of efficiency, resolution and induced background. The use of the monitor in the measurement of neutron capture cross-sections at n(-)TOF is discussed. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 17 条
[1]  
*ADS, 2000, P 6 INF EXCH M ACT F
[2]   First results from the neutron facility (nTOF) at CERN [J].
Borcea, C ;
Buono, S ;
Cennini, P ;
Dahlfors, M ;
Dangendorf, V ;
Ferrari, A ;
Garcia-Munoz, G ;
Kadi, Y ;
Lacoste, V ;
Nolte, R ;
Radermacher, E ;
Rubbia, C ;
Saldana, R ;
Vlachoudis, V ;
Weierganz, T ;
Zanini, L .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1) :S55-S57
[3]   Accelerator-driven systems for nuclear waste transmutation [J].
Bowman, CD .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1998, 48 :505-556
[4]  
*CERN, 1994, GEANT DET DESCR SIM
[5]   Simulations of neutron transport at low energy: A comparison between GEANT and MCNP [J].
Colonna, N ;
Altieri, S .
HEALTH PHYSICS, 2002, 82 (06) :840-846
[6]  
*CROSS SECT EV WOR, 1991, BNLNCS17541
[7]   INTERNATIONAL INTERCOMPARISON OF FAST-NEUTRON FLUENCE-RATE MEASUREMENTS USING FISSION CHAMBER TRANSFER INSTRUMENTS [J].
GAYTHER, DB .
METROLOGIA, 1990, 27 (04) :221-231
[8]  
*GEANT 4 COLL, 9844 CERNLHC
[9]   Current quests in nuclear astrophysics and experimental approaches [J].
Kappeler, F ;
Thielemann, FK ;
Wiescher, M .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 1998, 48 :175-251
[10]  
*NTOF COLL, 2000, 2000018 CERNINTC