Outcome of young patients with abandoned, nonfunctional endocardial leads

被引:42
作者
Silvetti, Massimo S. [1 ]
Drago, Fabrizio [1 ]
机构
[1] Bambino Gesu Pediat Hosp, Dept Pediat Cardiol, Rome, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2008年 / 31卷 / 04期
关键词
cardiac pacing; pacemaker; pediatric age; endocardial leads; lead malfunction; pacing; complications;
D O I
10.1111/j.1540-8159.2008.01017.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transvenous leads may fail and may be extracted or abandoned. There are no reports of the outcome of children with abandoned nonfunctional leads. Methods: We evaluated retrospectively the outcome of these patients, in our population of pacemaker (PM) patients. Data are reported as median (range). Results: In 18 patients (of 245, 7%) with endocardial pacing systems implanted at 4 (0.3-19) years of age (15 VVIR and 3 DDD PM), 19 leads (16 ventricular, 3 atrial) failed (abnormal threshold increase in seven leads; exit block in nine including three atria] leads; insulation break in three) after 10 (3-15) years, and were abandoned. At 13 (6-30) years of age, seven patients received VDD PM, seven VVIR, three DDD, and one patient an epicardial system. Median number of abandoned leads is one (two in two patients). Final cross-sectional area (CSA) of the implanted leads is eight (2-14) mm(2). All the procedures were successfully completed. Follow-up (FU) duration is 4 (1-10) years. All new leads are functioning normally. No tricuspid valve dysfunction or new venous occlusion occurred. Two cases of lead endocarditis occurred after 5 and 10 years of follow-up in patients with two ventricular leads. No specific risk factors for endocarditis were identified. Conclusions: Abandonment of a nonfunctioning lead is a palliative procedure, technically feasible, with no short-term complication. Two patients experienced late endocarditis of the leads.
引用
收藏
页码:473 / 479
页数:7
相关论文
共 24 条
[1]   Age, size, and lead factors alone do not predict venous obstruction in children and young adults with transvenous lead systems [J].
Bar-Cohen, Yaniv ;
Berul, Charles I. ;
Alexander, Mark E. ;
Fortescue, Elizabeth B. ;
Walsh, Edward P. ;
Triedman, John K. ;
Cecchin, Frank .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (07) :754-759
[2]  
Bongiorni MG, 2004, G ITAL ARITMOL CARDI, V3, P167
[3]   Clinical study of the laser sheath for lead extraction: The total experience in the United States [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Reiser, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (05) :804-808
[4]   Effectiveness of transvenous pacemaker leads placed through intravascular stents in patients with congenital heart disease [J].
Chintala, K ;
Forbes, TJ ;
Karpawich, PP .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (03) :424-427
[5]   VDD lead-lead interaction and atrial oversensing: An acute animal study [J].
Cohen, MI ;
Brabec, S ;
Shindeldecker, B ;
Laske, TG ;
Coles, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (06) :679-681
[6]   Pediatric pacemaker infections: Twenty years of experience [J].
Cohen, MI ;
Bush, DM ;
Gaynor, JW ;
Vetter, VL ;
Tanel, RE ;
Rhodes, LA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (04) :821-827
[7]  
Feigenbaum H., 1986, Echocardiography, V4th, P249
[8]   Patient, procedural, and hardware factors associated with pacemaker lead failures in pediatrics and congenital heart disease [J].
Fortescue, EB ;
Berul, CI ;
Cecchin, F ;
Walsh, EP ;
Triedman, JK ;
Alexander, ME .
HEART RHYTHM, 2004, 1 (02) :150-159
[9]  
Friedman RA, 1996, PACE, V19, P778
[10]   Laser-assisted lead extraction: the European experience [J].
Kennergren, C. ;
Bucknall, C. A. ;
Butter, C. ;
Charles, R. ;
Fuhrer, J. ;
Grosfeld, M. ;
Tavernier, R. ;
Morgado, T. B. ;
Mortensen, P. ;
Paul, V. ;
Richter, P. ;
Schwartz, T. ;
Wellens, F. .
EUROPACE, 2007, 9 (08) :651-656