Amperometric Biosensor for Choline Based on Gold Screen-Printed Electrode Modified with Electrochemically-Deposited Silica Biocomposite

被引:19
|
作者
Mazurenko, I. [1 ,3 ,4 ]
Tananaiko, O. [1 ]
Biloivan, O. [2 ]
Zhybak, M. [2 ]
Pelyak, I. [1 ]
Zaitsev, V. [1 ,5 ]
Etienne, M. [3 ,4 ]
Walcarius, A. [3 ,4 ]
机构
[1] Taras Shevchenko Natl Univ Kyiv, Dept Analyt Chem, UA-01033 Kiev, Ukraine
[2] NAS Ukraine, Lab Biomol Elect, Inst Mol Biol & Genet, UA-03143 Kiev, Ukraine
[3] Univ Lorraine, F-54600 Villers Les Nancy, France
[4] CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
[5] Pontificia Univ Catolica Rio de Janeiro, Dept Chem, BR-22451900 Rio De Janeiro, Brazil
关键词
Amperometric biosensor; Choline oxidase; Screen-printed electrode; Sol-gel; Electrochemically-assisted deposition; PRUSSIAN BLUE; THIN-FILMS; ENZYME ELECTRODE; OXIDASE; NANOPARTICLES; GLUCOSE; ACETYLCHOLINE; ENCAPSULATION; SENSORS; IMMOBILIZATION;
D O I
10.1002/elan.201400694
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mediator-free choline biosensor was developed using the electrochemically assisted sol-gel deposition on gold screen-printed electrodes. The addition of 12 mM of cationic surfactant CTAB in silica sol allowed enhancing the stability of the sensor. The modified electrode demonstrated catalytic activity and stable amperometric response to choline for over 3 weeks of exploitation with the sensitivity of 6 mu AmM1 and LOD of 6 mu M. The interference of ascorbic acid was reduced by pretreating the analyzed solution with MnO2 powder. The application of the sensor with the purpose of identifying choline in the baby milk demonstrated satisfactory metrological characteristics.
引用
收藏
页码:1685 / 1692
页数:8
相关论文
共 50 条
  • [21] A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode
    Khumngern, Suntisak
    Jirakunakorn, Ratchaneekorn
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Numnuam, Apon
    Bioelectrochemistry, 2021, 138
  • [22] A Disposable Cholesterol Enzyme Biosensor Based on Ferrocene-Capped Gold Nanoparticle Modified Screen-Printed Carbon Electrode
    Feng, Bijun
    Liu, You-Nian
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (06): : 4770 - 4778
  • [23] Biosensor for aluminium(III) based on its inhibition of α-chymotrypsin immobilized on a screen-printed carbon electrode modified with gold nanoparticles
    Barquero-Quiros, Miriam
    Dominguez-Renedo, Olga
    Asuncion Alonso-Lomillo, Maria
    Julia Arcos-Martinez, Maria
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 65 - 70
  • [24] A Highly Sensitive Biosensor Based on a 3D Gold Nanostructure Modified Screen-Printed Electrode for Glucose Detection
    Liu, His-Chien
    Tsai, Chung-Che
    Chang, Kang J.
    Wang, Gou-Jen
    2013 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP), 2013,
  • [25] Disposable biosensor based on a hemoglobin colloidal gold-modified screen-printed electrode for determination of hydrogen-peroxide
    Xu, XX
    Liu, SQ
    Ju, HX
    IEEE SENSORS JOURNAL, 2004, 4 (04) : 390 - 394
  • [26] Biosensor for aluminium(III) based on its inhibition of α-chymotrypsin immobilized on a screen-printed carbon electrode modified with gold nanoparticles
    Miriam Barquero-Quirós
    Olga Domínguez-Renedo
    Maria Asunción Alonso-Lomillo
    María Julia Arcos-Martínez
    Microchimica Acta, 2012, 179 : 65 - 70
  • [27] Gold Nanoparticles Decorated on Carbon Nanotube Modified Screen-printed Electrode for Flow Injection Amperometric Determination of Methyldopa
    Upan, Jantima
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (03): : 537 - 546
  • [28] Flow Injection Tyrosinase Amperometric Biosensor with A Single-Layer Graphene Modified Screen-Printed Electrode for Determination of Acetaminophen
    Frangu, Arber
    Sys, Milan
    Arbneshi, Tahir
    Vytras, Karel
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXVIII, 2018, : 50 - 53
  • [29] An Amperometric Nitrobenzene Electrochemical Sensor Based on Electrochemically Activated Graphite Modified Screen Printed Carbon Electrode
    Thirumalraj, Balamurugan
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (05): : 4173 - 4182
  • [30] Amperometric biosensor based on Laccase immobilized onto a screen-printed electrode by Matrix Assisted Pulsed Laser Evaporation
    Verrastro, Maria
    Cicco, Nunzia
    Crispo, Fabiana
    Morone, Antonio
    Dinescu, Maria
    Dumitru, Marius
    Favati, Fabio
    Centonze, Diego
    TALANTA, 2016, 154 : 438 - 445