Improvement Method of Fast and Isocratic RP-HPLC Analysis of Major Diterpene Glycoside from Stevia rebaudiana Leaves

被引:7
|
作者
Martono, Yohanes [1 ,2 ]
Riyanto, Sugeng [1 ]
Rohman, Abdul [1 ]
Martono, Sudibyo [1 ]
机构
[1] Gadjah Mada Univ, Fac Pharm, Yogyakarta 55221, Indonesia
[2] SatyaWacana Christian Univ, Dept Chem, Salatiga 50733, Indonesia
关键词
LIQUID-CHROMATOGRAPHY; PLANT-MATERIAL; STEVIOSIDE; REBAUDIOSIDE; QUANTIFICATION; SWEETENER;
D O I
10.1063/1.4958509
中图分类号
O59 [应用物理学];
学科分类号
摘要
Stevioside and rebaudioside A are major diterpene glycoside from Stevia rebaudiana. These compounds have similar structure and make both compounds have close polarity. The aim of this study was to improve isocratic RP-HPLC analysis to achieve a complete separation of stevioside and rebaudioside A in baseline peak. The method improved was conducted on Eurosphere C-18 (250 x 4.6 mm, 5 mu m) as the stationary phase. Mobile phase was made by a mixture of water-methanol (90: 10, v / v, pH = 3.0); acetonitrile, and trifluoroacetic acid (TFA) in the ratio 65: 35: 0.01 (v/v/v). Flow rate of mobile phase was 0.6 mL/min. The detection was performed in UV-210 nm. The improved method has complete separation by R > 2.00 in baseline peak. The linearity of the standard curve was obtained with a correlation coefficient of 0.9998 for rebaudioside A and 0.9994 for stevioside. The percent recovery was determined by standard addition method with a mean recovery of 100.82% for rebaudioside A and 101.04% for stevioside. The relative standard deviation (RSD) of intraday precision varies from 0.34 - 1.79% for rebaudioside A and 0.31 - 1.81% for stevioside, and interday precision showed RSD 1.47% for rebaudioside A and 0.37% for stevioside. While the sensitivity reported in the limit of detection (LOD) value of method improvement was 1.00 mu g/mL for both rebaudioside A and stevioside. The limit of quantitation (LOQ) of the method was 3.00 mu g/mL for both respected compounds. The small changes of the mobile phase composition, the mobile phase is reused after 1 week, flow rate, and column temperature did not alter the method performance significantly. The reliable and robust of the developed and validated method was applied to both simple and complex matrices of samples including S. rebaudiana leaves for major diterpene glycoside analysis.
引用
收藏
页数:8
相关论文
共 36 条
  • [21] Rapid method for estimating octanol-water partition coefficient (log Poct) from isocratic RP-HPLC and a hydrogen bond acidity term (A)
    Du, CM
    Valko, K
    Bevan, C
    Reynolds, D
    Abraham, MH
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2001, 24 (05) : 635 - 649
  • [22] SIMULTANEOUS QUANTIFICATION OF THREE NAPHTHOQUINONES FROM IMPATIENS BALSAMINA L. LEAVES USING VALIDATED RP-HPLC METHOD
    Sonandkar, A. A.
    Agrawal, P. N.
    Madrewar, D. M.
    Labana, S. M.
    Jain, A. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (10): : 4281 - 4287
  • [23] Development and Validation of an Isocratic, Sensitive and Facile RP-HPLC Method for Rapid Analysis of 5-Fluorouracil and Stability Studies Under Various Stress Conditions
    Haq, Nazrul
    Shakeel, Faiyaz
    Alanazi, Fars K.
    Radwan, Awwad A.
    Ali, Mohammad
    Alsarra, Ibrahim A.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (13) : 7177 - 7182
  • [24] Sensitive and selective method for the analysis of menthol from pharmaceutical products by RP-HPLC with refractive index detector
    Shaikh, K. A.
    Patil, Sachin D.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2010, 2 (04): : 360 - 364
  • [25] Development and Validation of RP-HPLC Method for Simultaneous Analysis of Andrographolide, Phyllanthin, and Hypophyllanthin from Herbal Hepatoprotective Formulation
    Bhope, S. G.
    Kuber, V. V.
    Nagore, D. H.
    Gaikwad, P. S.
    Patil, M. J.
    ACTA CHROMATOGRAPHICA, 2013, 25 (01) : 159 - 169
  • [26] Method development and validation for simultaneous determination of Eletriptan hydrobromide and Itopride hydrochloride from fast dissolving buccal films by using RP-HPLC
    Siddique, Waqar
    Sarfraz, Rai muhammad
    Zaman, Muhammad
    Khan, Riffat
    Gul, Maria
    Asghar, Farhan
    Malik, Tangina
    Saif, Asiya
    Shamim, Qurat-Ul-Ain
    Salawi, Ahmad
    Alshamrani, Meshal
    Almoshari, Yosif
    Sabei, Fahad Y.
    ACTA CHROMATOGRAPHICA, 2023, 35 (04) : 310 - 318
  • [27] Isolation and isotopic analysis of individual amino acids from archaeological bone collagen: A new method using RP-HPLC
    O'Connell, TC
    Hedge, REM
    ARCHAEOMETRY, 2001, 43 : 421 - 438
  • [28] RP-HPLC method validation for fast extraction and quantification of Levonorgestrel drug from silicone based intrauterine device intended for in-process and finished formulation
    Midhu George Veeran
    Karthikeyan C.
    Bharaniraja B.
    Diksha Painuly
    Abi Santhosh Aprem
    DARU Journal of Pharmaceutical Sciences, 2021, 29 : 185 - 193
  • [29] RP-HPLC method validation for fast extraction and quantification of Levonorgestrel drug from silicone based intrauterine device intended for in-process and finished formulation
    Veeran, Midhu George
    Karthikeyan, C.
    Bharaniraja, B.
    Painuly, Diksha
    Aprem, Abi Santhosh
    DARU-JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 29 (01) : 185 - 193
  • [30] Determining Seasonal Changes in Three Major Phenolic Compounds from Bark of Saraca asoca in Comparison with Local Market Sample Using RP-HPLC Analysis
    Pushkar M. Ketkar
    Shraddha U. Nayak
    Sandeep R. Pai
    Rajesh K. Joshi
    National Academy Science Letters, 2015, 38 : 403 - 407