Diagnosis and management of cerebral malperfusion phenomena during aortic dissection repair by transesophageal Doppler echocardiographic monitoring

被引:10
作者
Coletti, G
Torracca, L
LaCanna, G
Maisano, F
Sebastiano, P
Fucci, C
Berra, P
Alfieri, O
机构
[1] II Division of Cardiac Surgery, Spedali Civili, Brescia
[2] Cardiology Department, Spedali Civili, Brescia
[3] Anaesthesiology Department, Spedali Civili, Brescia
[4] II Cardiochirurgia, Spedali Civili, 25125 Brescia
关键词
D O I
10.1111/j.1540-8191.1996.tb00062.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Early diagnosis and surgical decision making are the key for survival in acute type A aortic dissection (AAD-A). As such, transesophageal echocardiography (TEE) is a widely accepted tool in the diagnosis of AAD-A. Methods: We used TEE in 49 cases as the sole diagnostic examination of AAD-A since November 1989. It was particularly useful intraoperatively to detect cerebral malperfusion during AAD-A repair. We were able to accurately monitor the blood flow of the aortic arch by using TEE for all patients throughout the operation. Only two patients developed severe cerebral malperfusion after the distal anastomosis was finished under deep hypothermic circulatory arrest. TEE showed that the malperfusion after the bypass was re-established. In both cases the expanded false lumen blocked the true lumen. We immediately switched the perfusion cannula from the femoral artery to the ascending aortic graft to create antegrade flow. Results: The subsequent TEE showed only the flow in the true lumen. One patient recovered without any complication while the other suffered mild, temporary neurological defects. Cerebral malperfusion is a potential catastrophic complication of AAD-A, which may exist before surgery or be caused by the operation itself. Conclusions: We recommend continuous intraoperative TEE to monitor aortic arch flow during these operations. This allows immediate detection of cerebral malperfusion and prompt action can be taken to prevent irreversible brain damage.
引用
收藏
页码:355 / 358
页数:4
相关论文
共 9 条
[1]  
ADACHI H, 1991, CIRCULATION, V84, P14
[2]  
Borst H G, 1991, Semin Thorac Cardiovasc Surg, V3, P238
[3]  
CABROL C, 1981, J THORAC CARDIOV SUR, V81, P309
[4]   VASCULAR COMPLICATIONS ASSOCIATED WITH SPONTANEOUS AORTIC DISSECTION [J].
CAMBRIA, RP ;
BREWSTER, DC ;
GERTLER, J ;
MONCURE, AC ;
GUSBERG, R ;
TILSON, MD ;
DARLING, RC ;
HAMMOND, G ;
MEGERMAN, J ;
ABBOTT, WM .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (02) :199-209
[5]  
ERBEL R, 1987, BRIT HEART J, V58, P45
[6]  
GUILMET D, 1993, J CARDIOVASC SURG, V34, P23
[7]   TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHIC MONITORING FOR MALPERFUSION DURING AORTIC DISSECTION REPAIR [J].
NEUSTEIN, SM ;
LANSMAN, SL ;
QUINTANA, CS ;
SURIANI, R ;
ERGIN, A ;
GRIEPP, RB .
ANNALS OF THORACIC SURGERY, 1993, 56 (02) :358-361
[8]  
SVENSSON LG, 1990, CIRCULATION, V82, P24
[9]   RATIONALE AND TECHNIQUE FOR REPLACEMENT OF THE ASCENDING AORTA, ARCH, AND DISTAL AORTA USING A MODIFIED ELEPHANT TRUNK PROCEDURE [J].
SVENSSON, LG .
JOURNAL OF CARDIAC SURGERY, 1992, 7 (04) :301-312