Fiber Optic Hydrogen Sensor resisting Temperature Interference
被引:0
作者:
Yi, Zhang
论文数: 0引用数: 0
h-index: 0
机构:
CAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R ChinaCAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
Yi, Zhang
[1
]
Sheng, Li Qi
论文数: 0引用数: 0
h-index: 0
机构:
CAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R ChinaCAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
Sheng, Li Qi
[1
]
Zhi, Zhuang
论文数: 0引用数: 0
h-index: 0
机构:
CAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R ChinaCAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
Zhi, Zhuang
[1
]
Min, Zhang
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, Opt Fiber Sensor Lab, Beijing 100084, Peoples R ChinaCAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
Min, Zhang
[2
]
Zhen, Yang
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, Opt Fiber Sensor Lab, Beijing 100084, Peoples R ChinaCAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
Zhen, Yang
[2
]
Biao, Liao Yan
论文数: 0引用数: 0
h-index: 0
机构:
Tsinghua Univ, Dept Elect Engn, Opt Fiber Sensor Lab, Beijing 100084, Peoples R ChinaCAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
Biao, Liao Yan
[2
]
机构:
[1] CAEP, Inst Struct Mech, Box919-402, Mianyang 621900, Sichuan, Peoples R China
[2] Tsinghua Univ, Dept Elect Engn, Opt Fiber Sensor Lab, Beijing 100084, Peoples R China
来源:
21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS
|
2011年
/
7753卷
基金:
中国国家自然科学基金;
关键词:
Fiber optic hydrogen sensor;
Gas detection;
EFPI;
Temperature compensation;
D O I:
10.1117/12.883236
中图分类号:
TH7 [仪器、仪表];
学科分类号:
0804 ;
080401 ;
081102 ;
摘要:
The principle of an extrinsic Fabry-Perot interferometric (EFPI) optical fiber hydrogen sensor is introduced in the paper. In order to carry out the mathematic model of the relationship between the change of Fabry-Perot gap length and hydrogen concentration, the stress transfer model of the sensor is analyzed. Two channels temperature compensation method is used to avoid the interference caused by the variation of the environmental temperature, so the stability of the system is enhanced. The validity of theory has been proved by means of investigating the responsibility of the sensor in a function of the hydrogen concentration, and the analytic data was close to the experiment results. The feasibility of the sensor has been validated by the temperature experiment.