Walk-IT: An Open-Source Modular Low-Cost Smart Rollator

被引:9
作者
Fernandez-Carmona, Manuel [1 ]
Ballesteros, Joaquin [2 ]
Diaz-Boladeras, Marta [3 ]
Parra-Llanas, Xavier [3 ]
Urdiales, Cristina [1 ]
Manuel Gomez-de-Gabriel, Jesus [4 ]
机构
[1] Univ Malaga, Elect Technol Dept, Complejo Tecnol, Ingn Sistemas Integrados Grp, Malaga 29071, Spain
[2] Univ Malaga, Dept Comp Sci & Programming Languages, Complejo Tecnol, ITIS Software, Malaga 29071, Spain
[3] Tech Univ Catalonia UPC, Tech Res Ctr Dependency Care & Autonomous Living, Barcelona 08800, Spain
[4] Univ Malaga UMA, Syst Engn & Automat Dept, Malaga 29071, Spain
关键词
rehabilitation robotics; assistive technology; smart rollator; gait analysis; PARTIAL WEIGHT-BEARING; GAIT DISTURBANCES; REHABILITATION; PARAMETERS; SYSTEM; AGE;
D O I
10.3390/s22062086
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Rollators are widely used in clinical rehabilitation for gait assessment, but gait analysis usually requires a great deal of expertise and focus from medical staff. Smart rollators can capture gait parameters autonomously while avoiding complex setups. However, commercial smart rollators, as closed systems, can not be modified; plus, they are often expensive and not widely available. This work presents a low cost open-source modular rollator for monitorization of gait parameters and support. The whole system is based on commercial components and its software architecture runs over ROS2 to allow further customization and expansion. This paper describes the overall software and hardware architecture and, as an example of extended capabilities, modules for monitoring dynamic partial weight bearing and for estimation of spatiotemporal gait parameters of clinical interest. All presented tests are coherent from a clinical point of view and consistent with input data.
引用
收藏
页数:16
相关论文
共 39 条
[1]  
Abellanas A., 2008, P EUR 22 DRESD GERM, P464
[2]  
Alves J., 2017, P IEEE 5 PORT M BIOE, P1, DOI DOI 10.1109/ENBENG.2017.7889420
[3]   Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker's handles: Results on normal subjects [J].
Alwan, Majd ;
Ledoux, Alexandre ;
Wasson, Glenn ;
Sheth, Pradip ;
Huang, Cunjun .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (03) :380-389
[4]   Immediate or late weight bearing after uncemented total hip arthroplasty -: A study of functional recovery [J].
Andersson, L ;
Wesslau, A ;
Bodén, H ;
Dalén, N .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :1063-1065
[5]   The i-Walker: an intelligent pedestrian mobility aid [J].
Annicchiarico, R. ;
Barrue, C. ;
Benedico, T. ;
Campana, F. ;
Cortes, U. ;
Martinez-Velasco, A. .
ECAI 2008, PROCEEDINGS, 2008, 178 :708-+
[6]  
[Anonymous], 2005, SMART TECHNOLOGY AGI
[7]   A tele-monitoring system for gait rehabilitation with an inertial measurement unit and a shoe-type ground reaction force sensor [J].
Bae, Joonbum ;
Tomizuka, Masayoshi .
MECHATRONICS, 2013, 23 (06) :646-651
[8]   Gait Disturbances in Patients With Stroke [J].
Balaban, Birol ;
Tok, Fatih .
PM&R, 2014, 6 (07) :635-642
[9]   Automatic Assessment of a Rollator-User's Condition During Rehabilitation Using the i-Walker Platform [J].
Ballesteros, Joaquin ;
Urdiales, Cristina ;
Martinez, Antonio B. ;
Tirado, Marina .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (11) :2009-2017
[10]   On Gait Analysis Estimation Errors Using Force Sensors on a Smart Rollator [J].
Ballesteros, Joaquin ;
Urdiales, Cristina ;
Martinez, Antonio B. ;
van Dieen, Jaap H. .
SENSORS, 2016, 16 (11)