Exposed column-base plate strong-axis connections for small-size steel construction

被引:14
|
作者
Lim, Woo-Young [1 ]
Lee, Dongkeun [2 ]
You, Young-Chan [3 ]
机构
[1] Wonkwang Univ, Dept Architectural Engn, Iksan 54538, Jeonbuk, South Korea
[2] Antalya Int Univ, Dept Civil Engn, Antalya, Turkey
[3] Korea Inst Civil Engn & Bldg Technol, Bldg & Urban Res Inst, Gyeonggi Do, South Korea
关键词
Small-size steel structures; Exposed column-base plate strong-axis connections; Hysteretic behaviour; Seismic performance; Flexural strength; Stiffness; BEHAVIOR;
D O I
10.1016/j.jcsr.2017.06.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experimental study on exposed steel column-base plate connections subjected to both axial and lateral loadings is quite limited. Therefore, based on the intensive field investigation, nine specimens were tested to appraise the seismic performance of various column-base plate strong-axis connections of small-size steel structures in this study. The main parameters were the thickness of base plates, the embedment length of anchor bolts, and the presence of hook and rib plates. Flexural strength, deformation capacity, energy dissipation, and stiffness of the test specimens were investigated. Based on the test results, the hysteretic behaviour of exposed column-base plate strong-axis connections was significantly influenced by the base plate thickness as well as the number and embedment length of anchor bolts. However, the effect of rib plates on the flexural performance of column-base plate connections was negligible. The flexural stiffness of the specimens was approximately 15% of the flexural stiffness by the New Zealand Standard with the assumption that the supports were fixed. It was found that although column-base plate strong-axis connections were properly designed in accordance with design guides, the flexural performance of the connections could be unreliable without sufficient bond capacity between concrete and anchor bolts.
引用
收藏
页码:286 / 296
页数:11
相关论文
共 34 条
  • [31] Seismic behavior of circular exposed reinforced concrete-filled steel tubular column-base joint: Experimental, numerical and theoretical studies
    Duan, Linli
    Lang, Xin
    Mou, Ben
    STRUCTURES, 2024, 64
  • [32] Shear resistance of anchor bolt with small free edges in exposed type steel column base
    Asada H.
    Kishiki S.
    Yamada S.
    Journal of Structural and Construction Engineering, 2010, 75 (654): : 1517 - 1525
  • [33] 2D and 3D numerical modelling of exposed steel base plate connections under cyclic loading
    Singh, Gursarbjot
    Woods, Joshua
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2022, 49 (08) : 1402 - 1414
  • [34] MECHANICAL PRORERTIES OF EXPOSED COLUMN BASE CONNECTIONS FOR L- SHAPED COLUMNS FABRICATED USING CONCRETE-FILLED STEEL TUBES
    Su, Jing
    Zhou, Ting
    Chen, Zhi-Hua
    Wang, Xiao-Dun
    ADVANCED STEEL CONSTRUCTION, 2021, 17 (04): : 356 - 365