Oxidative degradation of herbicide diuron in aqueous medium by Fenton's reaction based advanced oxidation processes

被引:161
作者
Oturan, Mehmet A. [1 ]
Oturan, Nihal [1 ]
Edelahi, Mohamed C. [1 ,2 ]
Podvorica, Fetah I. [3 ]
El Kacemi, Kacem [2 ]
机构
[1] Univ Paris Est Marnela Vallee, Lab Geomateriaux & Environm, Marne La Vallee 2, France
[2] Univ Mohammed V Agdal, Fac Sci, Lab Electrochim & Chim Analyt, Rabat 1114, Maroc, Morocco
[3] Univ Prishtina, Fac Nat Sci, Dept Chem, Prishtina 10000, Kosovo, Serbia
关键词
Phenylurea herbicides; Fenton's reagent; Hydroxyl radicals; Electro-Fenton; AOPs; Mineralization; ELECTRO-FENTON; ANODIC-OXIDATION; PHOTOELECTRO-FENTON; ORGANIC POLLUTANTS; WASTE-WATER; ELECTROCHEMICAL DEGRADATION; HYDROGEN-PEROXIDE; DESTRUCTION; KINETICS; REMOVAL;
D O I
10.1016/j.cej.2011.03.072
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Advanced chemical, photochemical and electrochemical oxidation processes based on catalytic generation of hydroxyl radicals through Fenton's reagent are applied to remove herbicide diuron from aqueous medium. To enhance the oxidation power of Fenton's reagent, it was assisted photochemically (photo-Fenton) or electrochemically (electro-Fenton). Kinetic analysis showed that the oxidation of diuron by hydroxyl radicals follows a reaction kinetic of pseudo-first order. The apparent rate constants values and mineralization degree of different photochemical processes revealed the superiority of the photo-Fenton process in degradation rate (kinetics) and that of electro-Fenton process in cost effectiveness and process efficiency. The absolute rate constant for diuron oxidation by hydroxyl radical was determined as (4.75 +/- 0.20) x 10(9) L mol(-1) s(-1) by competition kinetics method taking benzoic acid as reference compound. Electro-Fenton process exhibits a very fast degradation kinetics achieving complete removal of 0.17 mM diuron in less than 6 min. The apparent current efficiency was determined: its maximum value of 28% at 0.6 h decreases with the treatment time to 11% at 3 h, i.e., when 89% of mineralization is achieved. When 300 mA was applied, higher mineralization efficiency of 96% was achieved. The photo-Fenton process exhibits also high mineralization efficiency reaching 97% TOC removal at 5 h under optimal operating conditions. Several oxidation by-products such as 3,[3,4-dichlorohydroxyphenyl]-1,1-methylurea, 3,[3-hydroxy 4-chlorohydroxyphenyl]-1,1-methylurea, 3-[trihydroxyphenyl]-1,1-dimethylurea, 3,[3-hydoxy-4-chlorophenyl]-1,1-methylurea, 3,[3-hydroxy-4-chlorophenyl]-1,1-dimethylurea, and dichloroaniline were identified by HPLC and LC-MS analyses evidencing two sites of attack of hydroxyl radical, the first being located on the aromatic ring and the second on the dimethylurea group. Based on the identification of aromatic intermediates, carboxylic acids and chloride ion released; a plausible diuron mineralization pathway is proposed. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 67 条
  • [1] Experimental design methodology applied to electro-Fenton treatment for degradation of herbicide chlortoluron
    Abdessalem, Aida Kesraoui
    Oturan, Nihal
    Bellakhal, Nizar
    Dachraoui, Mohamed
    Oturan, Mehmet A.
    [J]. APPLIED CATALYSIS B-ENVIRONMENTAL, 2008, 78 (3-4) : 334 - 341
  • [2] The "in-cell" and "ex-cell" Fenton treatment of phenol, 4-chlorophenol and aniline
    Agladze, G. R.
    Tsurtsumia, G. S.
    Jung, B. -I.
    Kim, J. -S.
    Gorelishvili, G.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2007, 37 (03) : 385 - 393
  • [3] Ammar S., 2007, Journal of Environmental Engineering and Management, V17, P89
  • [4] Degradation of atrazine in aqueous medium by electrocatalytically generated hydroxyl radicals. A kinetic and mechanistic study
    Balci, Beytul
    Oturan, Nihal
    Cherrier, Richard
    Oturan, Mehmet A.
    [J]. WATER RESEARCH, 2009, 43 (07) : 1924 - 1934
  • [5] Olive oil MillWastewater treatment by the electro-Fenton process
    Bellakhal, Nizar
    Oturan, Mehmet A.
    Oturan, Nihal
    Dachraoui, Mohamed
    [J]. ENVIRONMENTAL CHEMISTRY, 2006, 3 (05) : 345 - 349
  • [6] Anodic oxidation, electro-Fenton and photoelectro-Fenton treatments of 2,4,5-trichlorophenoxyacetic acid
    Boye, B
    Dieng, MM
    Brillas, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 557 : 135 - 146
  • [7] Degradation of herbicide 4-chlorophenoxyacetic acid by advanced electrochemical oxidation methods
    Boye, B
    Dieng, MM
    Brillas, E
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (13) : 3030 - 3035
  • [8] Electrochemical destruction of chlorophenoxy herbicides by anodic oxidation and electro-Fenton using a boron-doped diamond electrode
    Brillas, E
    Boye, B
    Sirés, I
    Garrido, JA
    Rodríguez, RM
    Arias, C
    Cabot, PL
    Comninellis, C
    [J]. ELECTROCHIMICA ACTA, 2004, 49 (25) : 4487 - 4496
  • [9] Aniline mineralization by AOP's: anodic oxidation, photocatalysis, electro-Fenton and photoelectro-Fenton processes
    Brillas, E
    Mur, E
    Sauleda, R
    Sanchez, L
    Peral, J
    Domenech, X
    Casado, J
    [J]. APPLIED CATALYSIS B-ENVIRONMENTAL, 1998, 16 (01) : 31 - 42
  • [10] Degradation of 4-chlorophenol by anodic oxidation, electro-Fenton, photoelectro-Fenton, and peroxi-coagulation processes
    Brillas, E
    Sauleda, R
    Casado, J
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1998, 145 (03) : 759 - 765