Establishment and validation of an SIL-IS LC-MS/MS method for the determination of ibuprofen in human plasma and its pharmacokinetic study

被引:6
作者
Wang, Changmao [1 ]
Wang, Yaqin [2 ]
Xie, Haitang [1 ]
Zhan, Cuijiao [1 ]
He, Xuejun [2 ]
Liu, Ran [2 ]
Hu, Rongfeng [3 ]
Shen, Jie [2 ]
Jia, Yuanwei [1 ]
机构
[1] Wannan Med Coll, Pharm Sch, Wuhu, Anhui, Peoples R China
[2] Wannan Med Coll, Yijishan Hosp, Anhui Prov Ctr Drug Clin Evaluat, Wuhu, Anhui, Peoples R China
[3] Anhui Univ Tradit Chinese Med, Key Lab Xinan Med, Minist Educ, Key Lab R&D Chinese Med,Anhui 115 Xinan Med Res &, Hefei, Anhui, Peoples R China
基金
美国国家科学基金会;
关键词
human plasma; ibuprofen; LC-MS; MS; pharmacokinetics; stable isotopically labeled internal standard; ALZHEIMERS-DISEASE; LIQUID-CHROMATOGRAPHY; POLYMORPHISMS; ENANTIOMERS; CYP2C8;
D O I
10.1002/bmc.5287
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, we developed and validated a highly sensitive, rapid and stable LC-MS/MS method for the determination of ibuprofen in human plasma with ibuprofen-d3 as a stable isotopically labeled internal standard (SIL-IS). Human plasma samples were prepared by one-step protein precipitation. The chromatographic separation was achieved on a Poroshell 120 EC-C-18 (2.1 x 50 mm, 2.7 mu m). Aqueous solution (containing 0.05% acetic acid and 5 mm NH4Ac) and methanol were selected as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in negative ion mode. Multiple reaction monitoring mode was used for quantification using target fragment ions m/z 205.0 -> 161.1 for ibuprofen and m/z 208.0 -> 164.0 for SIL-IS, respectively. This method exhibited a linear range of 0.05-36 mu g/ml for ibuprofen with correlation coefficient >0.99. Mean recoveries of ibuprofen in human plasma ranged from 78.4 to 80.9%. The RSD of intra- and inter-day precision were both < 5%. The accuracy was between 88.2 and 103.67%. The matrix effect was negligible in human plasma, including lipidemia and hemolytic plasma. A simple, efficient and accurate LC-MS/MS method was successfully established and applied to a pharmacokinetic study in healthy Chinese volunteers after a single oral administration of ibuprofen granules.
引用
收藏
页数:8
相关论文
共 27 条
[1]   Ibuprofen and NSAID Use in COVID-19 Infected Patients Is Not Associated with Worse Outcomes: A Prospective Cohort Study [J].
Abu Esba, Laila Carolina ;
Alqahtani, Rahaf Ali ;
Thomas, Abin ;
Shamas, Nour ;
Alswaidan, Lolowa ;
Mardawi, Gahdah .
INFECTIOUS DISEASES AND THERAPY, 2021, 10 (01) :253-268
[2]   Determination of ibuprofen enantiomers in human plasma by HPLC-MS/MS: validation and application in neonates [J].
Chen, Tingting ;
Li, Qin ;
Lu, Jinmiao ;
Yu, Chen ;
Chen, Chao ;
Li, Zhiping .
BIOANALYSIS, 2016, 8 (12) :1237-1250
[3]  
Chinese Pharmacopoeia Commission, 2015, CHINESE PHARMACOPOEI, V2015, P9012
[4]  
Commission of Human Medicines, 2020, CEMCMO2020017
[5]   Targeting neuroinflammation in Alzheimer's disease: evidence for NSAIDs and novel therapeutics [J].
Deardorff, William James ;
Grossberg, George T. .
EXPERT REVIEW OF NEUROTHERAPEUTICS, 2017, 17 (01) :17-32
[6]  
EMA,, 2011, Guideline on bioanalytical method validation
[7]   Validation of a liquid chromatographic method for the determination of ibuprofen in human plasma [J].
Farrar, H ;
Letzig, L ;
Gill, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02) :341-348
[8]   Determination of nonsteroidal anti-inflammatory drugs in human tear and plasma samples using ultra-fast liquid chromatography-tandem mass spectrometry [J].
Hirosawa, Makiko ;
Sambe, Takehiko ;
Uchida, Naoki ;
Lee, Xiao-Pen ;
Sato, Keizo ;
Kobayashi, Shinichi .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2015, 59 (05) :364-371
[9]   LC-MS/MS法测定人血浆中布洛芬对映体浓度及其药动学研究 [J].
黄明 ;
张全英 ;
宗顺麟 .
药学学报, 2017, 52 (10) :1587-1591
[10]  
Hussain A., 2006, BIOMED CHROMATOGR, V8, P1263