Neutronic design and measured performance of the Low Energy Neutron Source (LENS) target moderator reflector assembly

被引:52
作者
Lavelle, C. M. [1 ]
Baxter, D. V. [1 ]
Bogdanov, A. [1 ]
Derenchuk, V. P. [1 ]
Kaiser, H. [1 ]
Leuschner, M. B. [1 ]
Lone, M. A.
Lozowski, W. [1 ]
Nann, H. [1 ]
Przewoski, B. v. [1 ]
Rernmes, N. [1 ]
Rinckel, T. [1 ]
Shin, Y. [1 ]
Snow, W. M. [1 ]
Sokol, P. E. [1 ]
机构
[1] IUCF, Bloomington, IN 47408 USA
基金
美国国家科学基金会;
关键词
neutronics; moderators; neutron sources; MCNP;
D O I
10.1016/j.nima.2007.12.044
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Low Energy Neutron Source (LENS) is an accelerator-based pulsed cold neutron facility under construction at the Indiana University Cyclotron Facility (IUCF). The idea behind LENS is to produce pulsed cold neutron beams starting with similar to MeV neutrons from (p,n) reactions in Be which are moderated to meV energies and extracted from a small solid angle for use in neutron instruments which can operate efficiently with relatively broad (similar to 1 ms) neutron pulse widths. Although the combination of the features and operating parameters of this source is unique at present, the neutronic design possesses several features similar to those envisioned for future neutron facilities such as long-pulsed spallation sources (LPSS) and very cold neutron (VCN) sources. We describe the underlying ideas and design details of the target/moderator/reflector system (TMR) and compare measurements of its brightness, energy spectrum, and emission time distribution under different moderator configurations with MCNP simulations. Brightness measurements using an ambient temperature water moderator agree with MCNP simulations within the 20% accuracy of the measurement. The measured neutron emission time distribution from a solid methane moderator is in agreement with simulation and the cold neutron flux is sufficient for neutron scattering studies of materials. We describe some possible modifications to the existing design which would increase the cold neutron brightness with negligible effect on the emission time distribution. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:324 / 341
页数:18
相关论文
共 63 条
[1]  
*ASTM INT, 2003, ANN BOOK ASTM STAND, V12
[2]   Status of the low energy neutron source at Indiana University [J].
Baxter, DV ;
Cameron, JM ;
Derenchuk, VP ;
Lavelle, CM ;
Leuschner, MB ;
Lone, MA ;
Meyer, HO ;
Rinckel, T ;
Snow, WM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 241 (1-4) :209-212
[3]  
BAXTER DV, 2004, ICANS 17 LOS AL NEUT, V1, P18
[4]   TOF powder diffractometer on a reactor source [J].
Bleif, HJ ;
Wechsler, D ;
Mezei, F .
PHYSICA B, 2000, 276 :181-182
[5]   NEUTRON YIELDS FROM THICK BE TARGETS BOMBARDED WITH DEUTERONS OR PROTONS [J].
BREDE, HJ ;
DIETZE, G ;
KUDO, K ;
SCHREWE, UJ ;
TANCU, F ;
WEN, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2) :332-344
[6]   CROSS-SECTION MEASUREMENT AND LANE MODEL ANALYSIS FOR THE BE-9(P,N)B-9 REACTION [J].
BYRD, RC ;
FLOYD, CE ;
GUSS, PP ;
MURPHY, K ;
WALTER, RL .
NUCLEAR PHYSICS A, 1983, 399 (01) :94-118
[7]   New scattering kernels for some materials of interest as advanced cold neutron moderators [J].
Cantargi, F. ;
Granada, J. R. ;
Petriw, S. ;
Sbaffoni, M. M. .
PHYSICA B-CONDENSED MATTER, 2006, 385-86 :1312-1314
[8]   THERMALLY ACTIVATED RELEASE OF STORED CHEMICAL ENERGY IN CRYOGENIC MEDIA [J].
CARPENTER, JM .
NATURE, 1987, 330 (6146) :358-360
[9]  
CARPENTER JM, 1985, P 8 M INT COLL ADV N, P311
[10]  
CARPENTER JM, 1986, METHODS EXPT PHYS A, V23, pCH2