Self-aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions

被引:48
作者
Asano, KG [1 ]
Ford, MJ [1 ]
Tomkins, BA [1 ]
Van Berkel, GJ [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Organ & Biol Mass Spectrometry Grp, Oak Ridge, TN 37831 USA
关键词
D O I
10.1002/rcm.2062
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A self-aspirating heated nebulizer probe is described and demonstrated for use in the direct analysis of analytes on surfaces and in liquid samples by atmospheric pressure chemical ionization (APCI) mass spectrometry. Functionality and performance of the probe as a self-aspirating APCI source is demonstrated using reserpine and progesterone as test compounds. The utility of the probe to sample analytes directly from surfaces was demonstrated first by scanning development lanes of a reversed-phase thin-layer chromatography plate in which a three-component dye mixture, viz., Fat Red 7B, Solvent Green 3, and Solvent Blue 35, was spotted and the components were separated. Development lanes were scanned by the sampling probe operated under computer control (x, y plane) while full-scan mass spectra were recorded using a quadrupole ion trap mass spectrometer. In addition, the ability to sample the surface of pharmaceutical tablets (viz., Extra Strength Tylenol(R) and Evista(R) tablets) and to detect the active ingredients (acetaminophen and raloxifene, respectively) selectively was demonstrated using tandem mass spectrometry (MS/MS). Finally, the capability to sample analyte solutions from the wells of a 384-well microtiter plate and to perform quantitative analyses using MS/MS detection was illustrated with cotinine standards spiked with cotinine-d(3) as an internal standard. Published in 2005 by John Wiley & Sons, Ltd.
引用
收藏
页码:2305 / 2312
页数:8
相关论文
共 18 条
  • [1] MASS-SPECTROMETRY WITH ION SOURCES OPERATING AT ATMOSPHERIC-PRESSURE
    BRUINS, AP
    [J]. MASS SPECTROMETRY REVIEWS, 1991, 10 (01) : 53 - 77
  • [2] Practical implications of some recent studies in electrospray ionization fundamentals
    Cech, NB
    Enke, CG
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (06) : 362 - 387
  • [3] Simultaneous determination of paracetamol and chlorpheniramine in human plasma by liquid chromatography-tandem mass spectrometry
    Celma, C
    Allué, JA
    Pruñonosa, J
    Peraire, C
    Obach, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 77 - 86
  • [4] Versatile new ion source for the analysis of materials in open air under ambient conditions
    Cody, RB
    Laramée, JA
    Durst, HD
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (08) : 2297 - 2302
  • [5] Crecelius A, 2003, LC GC EUR, V16, P225
  • [6] Automated high-throughput infusion ESI-MS with direct coupling to a microtiter plate
    Felten, C
    Foret, F
    Minarik, M
    Goetzinger, W
    Karger, BL
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (07) : 1449 - 1454
  • [7] Ford MJ, 2004, RAPID COMMUN MASS SP, V18, P1303, DOI 10.1002/rcm.1486
  • [8] FORD MJ, 2005, IN PRESS J MASS SPEC
  • [9] Interfacing matrix-assisted laser desorption/ionization mass spectrometry with column and planar separations
    Gusev, AI
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7): : 691 - 700
  • [10] Scanning capillary microscopy/mass spectrometry for mapping spatial electrochemical activity of electrodes
    Modestov, AD
    Srebnik, S
    Lev, O
    Gun, J
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (17) : 4229 - 4240