Selective protein quantification for preparative chromatography using variable pathlength UV/Vis spectroscopy and partial least squares regression

被引:55
作者
Brestrich, Nina [1 ]
Ruedt, Matthias [1 ]
Buechler, Daniel [1 ]
Hubbuch, Juergen [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Engn Life Sci, Sect Biomol Separat Engn 4, Engler Bunte Ring 3, D-76131 Karlsruhe, Germany
基金
欧盟地平线“2020”;
关键词
Preparative chromatography; Process Analytical Technology; Partial least squares regression; In-line monitoring; Variable pathlength spectroscopy; Selective protein quantification; PROCESS ANALYTICAL TECHNOLOGY; PERFORMANCE LIQUID-CHROMATOGRAPHY; IN-LINE QUANTIFICATION; CO-ELUTING PROTEINS; POOLING DECISIONS; TOOL; DECONVOLUTION; ULTRAVIOLET; CELL;
D O I
10.1016/j.ces.2017.10.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In preparative protein chromatography, broad dynamic ranges of protein concentrations as well as coelution of product and impurities are common. Despite being the standard in biopharmaceutical production, monitoring of preparative chromatography is generally limited to surrogate signals, e.g. UV absorbance at 280 nm. To address this problem, variable pathlength (VP) spectroscopy in conjunction with Partial Least Squares regression (PLS) was used to monitor preparative chromatography. While VP spectroscopy enabled the acquisition of absorbance data for a broad concentration range, PLS modelling allowed for the differentiation between the protein species. The approach was first implemented for monitoring the separation of lysozyme from cytochrome c at an overall loading density of 92 g/l. The same method was then applied to the polishing step of a monoclonal antibody (mAb) at 40 g/l loading density. For PLS model prediction of the mAb monomer and the high molecular weight variants (HMWs), the root mean square error (RMSE) was 1.07 g/l and 0.42 g/l respectively. To demonstrate the usability of the approach for in-line control, pooling decisions for both separation problems were subsequently taken based on the computed concentrations or thereof derived purities. In summary, VP spectroscopy in conjunction with PLS modelling is a promising option for in-line monitoring and control of future chromatography steps at large scale. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 25 条
  • [11] Guidance for Industry, 2004, PAT FRAM INN PHARM D
  • [12] A Label-Free Methodology for Selective Protein Quantification by Means of Absorption Measurements
    Hansen, Sigrid K.
    Skibsted, Erik
    Staby, Arne
    Hubbuch, Juergen
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2011, 108 (11) : 2661 - 2669
  • [13] Hoskuldsson A., 1988, Journal of Chemometrics, V2, P211, DOI [DOI 10.1002/CEM.1180020306, 10.1002/cem.1180020306]
  • [14] Jiskoot W., 2005, METHODS STRUCTURAL A
  • [15] Risk-benefit evaluation of on-line high-performance liquid chromatography analysis for pooling decisions in large-scale chromatography
    Kaltenbrunner, Oliver
    Lu, Yuefeng
    Sharma, Ashutosh
    Lawson, Ken
    Tressel, Tim
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1241 : 37 - 45
  • [16] LEDOUCEN R, 1985, J PHYS E SCI INSTRUM, V18, P199, DOI 10.1088/0022-3735/18/3/007
  • [17] Martens H., 1989, MULTIVARIATE CALIBRA
  • [18] Process analytical technology (PAT) for biopharmaceutical products
    Rathore, A. S.
    Bhambure, R.
    Ghare, V.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (01) : 137 - 154
  • [19] Application of process analytical technology for downstream purification of biotherapeutics
    Rathore, Anurag S.
    Kapoor, Gautam
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2015, 90 (02) : 228 - 236
  • [20] Large Scale Demonstration of a Process Analytical Technology Application in Bioprocessing: Use of On-line High Performance Liquid Chromatography for Making Real Time Pooling Decisions for Process Chromatography
    Rathore, Anurag S.
    Parr, Lilly
    Dermawan, Shinta
    Lawson, Ken
    Lu, Yuefeng
    [J]. BIOTECHNOLOGY PROGRESS, 2010, 26 (02) : 448 - 457