Selective protein quantification for preparative chromatography using variable pathlength UV/Vis spectroscopy and partial least squares regression

被引:55
作者
Brestrich, Nina [1 ]
Ruedt, Matthias [1 ]
Buechler, Daniel [1 ]
Hubbuch, Juergen [1 ]
机构
[1] Karlsruhe Inst Technol, Inst Engn Life Sci, Sect Biomol Separat Engn 4, Engler Bunte Ring 3, D-76131 Karlsruhe, Germany
基金
欧盟地平线“2020”;
关键词
Preparative chromatography; Process Analytical Technology; Partial least squares regression; In-line monitoring; Variable pathlength spectroscopy; Selective protein quantification; PROCESS ANALYTICAL TECHNOLOGY; PERFORMANCE LIQUID-CHROMATOGRAPHY; IN-LINE QUANTIFICATION; CO-ELUTING PROTEINS; POOLING DECISIONS; TOOL; DECONVOLUTION; ULTRAVIOLET; CELL;
D O I
10.1016/j.ces.2017.10.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In preparative protein chromatography, broad dynamic ranges of protein concentrations as well as coelution of product and impurities are common. Despite being the standard in biopharmaceutical production, monitoring of preparative chromatography is generally limited to surrogate signals, e.g. UV absorbance at 280 nm. To address this problem, variable pathlength (VP) spectroscopy in conjunction with Partial Least Squares regression (PLS) was used to monitor preparative chromatography. While VP spectroscopy enabled the acquisition of absorbance data for a broad concentration range, PLS modelling allowed for the differentiation between the protein species. The approach was first implemented for monitoring the separation of lysozyme from cytochrome c at an overall loading density of 92 g/l. The same method was then applied to the polishing step of a monoclonal antibody (mAb) at 40 g/l loading density. For PLS model prediction of the mAb monomer and the high molecular weight variants (HMWs), the root mean square error (RMSE) was 1.07 g/l and 0.42 g/l respectively. To demonstrate the usability of the approach for in-line control, pooling decisions for both separation problems were subsequently taken based on the computed concentrations or thereof derived purities. In summary, VP spectroscopy in conjunction with PLS modelling is a promising option for in-line monitoring and control of future chromatography steps at large scale. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 25 条
  • [1] Deconvolution of high-throughput multicomponent isotherms using multivariate data analysis of protein spectra
    Baumann, Pascal
    Huuk, Thiemo
    Hahn, Tobias
    Osberghaus, Anna
    Hubbuch, Juergen
    [J]. ENGINEERING IN LIFE SCIENCES, 2016, 16 (02): : 194 - 201
  • [2] Application of spectral deconvolution and inverse mechanistic modelling as a tool for root cause investigation in protein chromatography
    Brestrich, Nina
    Hahn, Tobias
    Hubbuch, Juergen
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1437 : 158 - 167
  • [3] Advances in inline quantification of co-eluting proteins in chromatography: Process-data-based model calibration and application towards real-life separation issues
    Brestrich, Nina
    Sanden, Adrian
    Kraft, Axel
    McCann, Karl
    Bertolini, Joseph
    Hubbuch, Juergen
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2015, 112 (07) : 1406 - 1416
  • [4] A tool for selective inline quantification of co-eluting proteins in chromatography using spectral analysis and partial least squares regression
    Brestrich, Nina
    Briskot, Till
    Osberghaus, Anna
    Hubbuch, Juergen
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2014, 111 (07) : 1365 - 1373
  • [5] Mid-Infrared Spectroscopy-Based Analysis of Mammalian Cell Culture Parameters
    Capito, Florian
    Zimmer, Aline
    Skudas, Romas
    [J]. BIOTECHNOLOGY PROGRESS, 2015, 31 (02) : 578 - 584
  • [6] Carta G., 2010, PROTEIN CHROMATOGRAP, P125, DOI 10.1002/9783527630158.ch4
  • [7] Development of variable pathlength UV-vis spectroscopy combined with partial-least-squares regression for wastewater chemical oxygen demand (COD) monitoring
    Chen, Baisheng
    Wu, Huanan
    Li, Sam Fong Yau
    [J]. TALANTA, 2014, 120 : 325 - 330
  • [8] Eriksson L., 2006, Multi and Megavariate Data Analysis, DOI [10.1002/cem.713, DOI 10.1002/CEM.713]
  • [9] Real-time control of purified product collection during chromatography of recombinant human insulin-like growth factor-I using an on-line assay
    Fahrner, RL
    Lester, PM
    Blank, GS
    Reifsnyder, DH
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (01) : 37 - 43
  • [10] Variable path length transmittance cell for ultraviolet, visible, and infrared spectroscopy and spectroelectrochemistry
    Flowers, PA
    Callender, SA
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (01) : 199 - 202