Home-monitoring of blood glucose in cats with diabetes mellitus:: evaluation over a 4-month period

被引:28
作者
Casella, M
Hässig, M
Reusch, CE
机构
[1] Univ Zurich, Clin Small Anim Internal Med, Vetsuisse Fac, CH-8057 Zurich, Switzerland
[2] Univ Zurich, Clin Obstet & Herd Hlth, Vetsuisse Fac, CH-8057 Zurich, Switzerland
关键词
D O I
10.1016/j.jfms.2004.08.006
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Home-monitoring of blood glucose concentrations has recently been introduced to owners. The objectives of this study were to investigate the feasibility of home-monitoring of blood glucose in diabetic cats by owners, the problems encountered and to compare glucose concentrations at home with those measured in the hospital. Twelve of 15 cat owners were able to generate glucose curves over the study period of 4 months. Most problems were related to restraining the cat, generating negative pressure with the lancing device and producing a blood drop. In the majority of cases, these problems could be resolved during the study. Blood glucose concentrations in the clinic tended to be lower than at home; some of the differences were significant. No association between tolerance of the procedure and blood glucose concentrations measured at home was found. We, therefore, assume that the lower glucose levels in the hospital were caused by lack of food intake. In 38% of cases, treatment based on hospital curves would have been different from that based on home curves. Home-monitoring appears to be a valuable tool in the management of cats with diabetes mellitus. One of its major advantages is that it enables frequent generation of blood glucose curves, which is of particular importance in cats that are difficult to regulate. (c) 2004 ESFM and AAFP. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 32 条
[1]  
*AM DIAB ASS, 1998, DIABETES CARE S1, V21, P69
[2]  
American Diabetes Association, 1996, DIABETES CARE, V19, P62
[3]   SELF-MONITORING OF BLOOD-GLUCOSE LEVELS IN DIABETES - PRINCIPLES AND PRACTICE [J].
BERGMAN, M ;
FELIG, P .
ARCHIVES OF INTERNAL MEDICINE, 1984, 144 (10) :2029-2034
[4]   Validation of home blood glucose meters with respect to clinical and analytical approaches [J].
Brunner, GA ;
Ellmerer, M ;
Sendlhofer, G ;
Wutte, A ;
Trajanoski, Z ;
Schaupp, L ;
Quehenberger, F ;
Wach, P ;
Krejs, GJ ;
Pieber, TR .
DIABETES CARE, 1998, 21 (04) :585-590
[5]   Home monitoring of blood glucose concentration by owners of diabetic dogs [J].
Casella, M ;
Wess, G ;
Hässig, M ;
Reusch, CE .
JOURNAL OF SMALL ANIMAL PRACTICE, 2003, 44 (07) :298-305
[6]   Measurement of capillary blood glucose concentrations by pet owners: A new tool in the management of diabetes mellitus [J].
Casella, M ;
Wess, G ;
Reusch, CE .
JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2002, 38 (03) :239-245
[7]  
CASELLA M, 2000, J VET INTERNAL MED, P754
[8]   Accuracy, precision and user-acceptability of self blood glucose monitoring machines [J].
Chan, JCN ;
Wong, RYM ;
Cheung, CK ;
Lam, P ;
Chow, CC ;
Yeung, VTF ;
Kan, ECY ;
Loo, KM ;
Mong, MYL ;
Cockram, CS .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1997, 36 (02) :91-104
[9]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[10]   HOME BLOOD-GLUCOSE MONITORING - A NEW APPROACH TO THE MANAGEMENT OF DIABETES-MELLITUS [J].
COHEN, M ;
ZIMMET, PZ .
MEDICAL JOURNAL OF AUSTRALIA, 1980, 2 (13) :713-716