Electrochemical behaviour of sertraline at a hanging mercury drop electrode and its determination in pharmaceutical products

被引:27
作者
Vela, MH [1 ]
Garcia, MBQ [1 ]
Montenegro, MCBSM [1 ]
机构
[1] Univ Porto, Fac Farm, Dept Quim Fis, CEQUP, P-4050 Porto, Portugal
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 369卷 / 7-8期
关键词
D O I
10.1007/s002160000686
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behaviour of sertraline at a hanging mercury drop electrode (HMDE) was described. Different voltammetric techniques, such as cyclic, linear sweep, differential pulse and square wave voltammetry, were used. Voltammograms were obtained at different pH values with a Britton-Robinson buffer solution used as supporting electrolyte. The best results were found by square wave voltammetry with electrodeposition at alkaline pH using a berate buffer with a pH = 8.2 for the samples, containing 12% (v/v) methanol. Under optimised conditions, a linear relationship between 2.33 x 10(-7) and 3.15 x 10(-6) M of sertraline with a limit of detection of 1.98 x 10(-7) M was obtained. The electrochemical method developed was applied to the determination of sertraline in pharmaceutical formulations. Recoveries were close to 100%, thus proving efficacy of the proposed method for the quantification of sertraline in commercial samples.
引用
收藏
页码:563 / 566
页数:4
相关论文
共 9 条
[1]   Electrochemical studies and square wave adsorptive stripping voltammetry of the antidepressant fluoxetine [J].
da Silva, AMSR ;
Lima, JC ;
Teles, MTO ;
Brett, AMO .
TALANTA, 1999, 49 (03) :611-617
[2]   Analytical methods for the quantitative determination of selective serotonin reuptake inhibitors for therapeutic drug monitoring purposes in patients [J].
Eap, CB ;
Baumann, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 686 (01) :51-63
[3]   PREPARATION OF UNIVERSAL BUFFER WITH IONIC-STRENGTH 0.3M [J].
FERNANDEZ, CM ;
MARTIN, VC .
TALANTA, 1977, 24 (12) :747-748
[4]   GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS AND PRELIMINARY HUMAN PHARMACOKINETICS OF SERTRALINE, A NEW ANTIDEPRESSANT DRUG [J].
FOUDA, HG ;
RONFELD, RA ;
WEIDLER, DJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 417 (01) :197-202
[5]  
GUPTA RN, 1994, CLIN CHEM, V40, P498
[6]   Electrochemical behaviour of Venlafaxine and its determination in pharmaceutical products using square wave voltammetry [J].
Lima, JLFC ;
Loo, DV ;
Delerue-Matos, C ;
da Silva, ASR .
FARMACO, 1999, 54 (03) :145-148
[8]   AUTOMATED GAS-CHROMATOGRAPHIC ELECTRON-CAPTURE ASSAY FOR THE SELECTIVE SEROTONIN UPTAKE BLOCKER SERTRALINE [J].
TREMAINE, LM ;
JOERG, EA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 496 (02) :423-429
[9]   THE POLAROGRAPHIC-DETERMINATION OF FLUVOXAMINE MALEATE [J].
TUNCEL, M ;
ALTIOKKA, G ;
ATKOSAR, Z .
ANALYTICAL LETTERS, 1994, 27 (06) :1135-1145