Contrast Enhancement and Robustness Improvement of Adaptive Ultrasound Imaging Using Forward-Backward Minimum Variance Beamforming

被引:74
|
作者
Asl, Babak Mohammadzadeh [1 ]
Mahloojifar, Ali [1 ]
机构
[1] Tarbiat Modares Univ, Dept Biomed Engn, Tehran, Iran
关键词
MEDICAL ULTRASOUND; SIGNALS;
D O I
10.1109/TUFFC.2011.1880
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In adaptive ultrasound imaging, accurate estimation of the array covariance matrix is of great importance, and biases the performance of the adaptive beamformer. The more accurately the covariance matrix can be estimated, the better the resolution and contrast can be achieved in the ultrasound image. To this end, in this paper, we have used the forward-backward spatial averaging for array covariance matrix estimation, which is then employed in minimum variance (MV) weights calculation. The performance of the proposed forward-backward MV (FBMV) beamformer is tested on simulated data obtained using Field II. Data for two closely located point targets surrounded by speckle pattern are simulated showing the higher amplitude resolution of the FBMV beamformer in comparison to the forward-only (F-only) MV beamformers, without the need for diagonal loading. A circular cyst with a diameter of 6 mm and a phantom containing wire targets and two cysts with different diameters of 8 mm and 6 mm are also simulated. The simulations show that the FBMV beamformer, in contrast to the F-only MV, could estimate the background speckle statistics without the need for temporal smoothing, resulting in higher contrast for the FBMV-resulted image in comparison to the MV images. In addition, the effect of steering vector errors is investigated by applying an error of the sound speed estimate to the ultrasound data. The simulations show that the proposed FBMV beamformer presents a satisfactory robustness against data misalignment resulted from steering vector errors, outperforming the regularized F-only MV beamformer. These improvements are achieved without compromising the good resolution of the MV beamformer and resulted from more accurate estimation of the covariance matrix and consequently, the more accurate setting of the MV weights.
引用
收藏
页码:858 / 867
页数:10
相关论文
共 50 条
  • [1] Forward-backward Minimum Variance Beamforming Combined with Coherence Weighting Applied to Ultrasound Imaging
    ZHOU Ting
    LI Qiao-liang
    CHEN Xin
    WANG Tian-fu
    CHEN Si-ping
    Chinese Journal of Biomedical Engineering, 2016, 25 (01) : 24 - 30
  • [2] Minimum variance adaptive beamforming applied to medical ultrasound imaging
    Synnevag, JF
    Austeng, A
    Holm, S
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 1199 - 1202
  • [3] Forward-backward generalized sidelobe canceler beamforming applied to medical ultrasound imaging
    Li, Jiake
    Chen, Xiaodong
    Wang, Yi
    Chen, Xiaoshuai
    Yu, Daoyin
    AIP ADVANCES, 2017, 7 (01)
  • [4] Resolving Ultrasound Contrast Microbubbles Using Minimum Variance Beamforming
    Diamantis, Konstantinos
    Anderson, Tom
    Butler, Mairead B.
    Villagomez-Hoyos, Carlos A.
    Jensen, Jorgen Arendt
    Sboros, Vassilis
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (01) : 194 - 204
  • [5] Adaptive minimum variance beamforming combined with phase coherence imaging for ultrasound imaging
    Xu, Mengling
    Chen, Yimin
    Ding, Mingyue
    Ming Yuchi
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [6] Enhancement of Despeckled Ultrasound Images by Forward-Backward Diffusion
    Nieniewski, Mariusz
    COMPUTER VISION AND GRAPHICS, ICCVG 2014, 2014, 8671 : 454 - 461
  • [7] Enhancement of despeckled ultrasound images by forward-backward diffusion
    Nieniewski, Mariusz
    Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 2014, 8671 : 454 - 461
  • [8] Broadband Minimum Variance Beamforming for Ultrasound Imaging
    Holfort, Iben Kraglund
    Gran, Fredrik
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) : 314 - 325
  • [9] Adaptive diagonal loaded minimum variance beamforming applied to medical ultrasound imaging
    刘昊霖
    张志宏
    刘东权
    Journal of Central South University, 2015, 22 (05) : 1826 - 1832
  • [10] Adaptive diagonal loaded minimum variance beamforming applied to medical ultrasound imaging
    Liu Hao-lin
    Zhang Zhi-hong
    Liu Dong-quan
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (05) : 1826 - 1832