Treatment of intertrochanteric femur fractures with 95A° fixed-angle blade plate in elderly patients

被引:0
作者
Kesemenli, Cumhur Cevdet [1 ]
Memisoglu, Kaya [1 ]
Necmioglu, Serdar [2 ]
Kayikci, Cuma [3 ]
机构
[1] Kocaeli Univ Sch Med, Dept Orthopaed & Traumatol, Izmit, Kocaeli, Turkey
[2] Dicle Univ Sch Med, Dept Orthopaed & Traumatol, Diyarbakir, Turkey
[3] Guneydogu Hosp, Orthopaed Clin, Diyarbakir, Turkey
关键词
Intertrochanteric femoral fracture; Internal fixation; Fixation; Fixed-angle blade plate; PERITROCHANTERIC FEMORAL FRACTURES; INTERNAL-FIXATION; HIP-FRACTURES; SUBTROCHANTERIC FRACTURES; EXTERNAL FIXATION; INTRAMEDULLARY; SCREW; NAILS;
D O I
10.1007/s00590-010-0627-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In this study, we aimed to evaluate the results of treatment of intertrochanteric femur fractures fixation with a 95A degrees fixed-angle blade plate in elderly patients. Fifty-eight patients with intertrochanteric femoral fractures were treated with 95A(0) fixed-angle blade plate. There were 32 female and 26 male patients. The fractures resulted from a simple fall in 42 patients, a motor vehicle accident in 6, and a fall from a height in 10 patients. The mean clinical follow-up was 27 months. Clinical outcomes were evaluated according to the American Academy of Orthopeadic Surgeons' criteria. Shortening greater than 2 cm was noted in these patients at last follow-up as a result of varus malunion, plate bending developed only in 3 patients, and the loss of reduction developed in two patients, but reoperation was not needed. According to these criteria, results were poor in 2 patients, fair in 6, good in 16 and excellent in 31 patients. Consequently, 95A degrees fixed-angle blade plates could be thought as a proper alternative technique due to their easy applicability, low learning curve and complication rates.
引用
收藏
页码:629 / 634
页数:6
相关论文
共 25 条
[21]  
Subasi M, 2001, Acta Orthop Belg, V67, P468
[22]  
Suriyajakyuthana Wichai, 2004, Journal of the Medical Association of Thailand, V87, P1431
[23]  
TENCER AF, 2002, INTERNAL FIXATION OS, P40
[24]   The role of total hip replacement in intertrochanteric fractures of the femur [J].
Waddell, JP ;
Morton, J ;
Schemitsch, EH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :49-53
[25]   Treatment of unstable peritrochanteric femoral fractures using a 95° angled blade plate [J].
Yoo, MC ;
Cho, YJ ;
Kim, KI ;
Khairuddin, M ;
Chun, YS .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (10) :687-692