Successful endovascular coil embolization of large pseudoaneurysm of ductus arteriosus diverticulum

被引:1
作者
Buechner, David [1 ,2 ]
Lippuner, Veronica [1 ]
DeMaio, Kristine [2 ]
Donovan, F. Daniel, Jr. [1 ,2 ]
Weber, Philip R. [1 ,2 ]
Schoettle, G. Phillip [3 ]
机构
[1] Memphis Radiol PC, 7695 Poplar Pike, Germantown, TN 38138 USA
[2] Univ Tennessee, Hlth Sci Ctr, Dept Radiol, Memphis, TN USA
[3] Methodist Bonheur Healthcare, Thorac & Cardiovasc Surg, Memphis, TN USA
关键词
TEVAR; Endovascular coil embolization; Thoracic aneurysm; Ductus arteriosus pseudoaneurysm; Thoracic aortic repair; ANEURYSM;
D O I
10.1186/s42155-019-0053-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPseudoaneurysm of the ductus arteriosus diverticulum, although rare in adults, may have catastrophic consequences if left untreated due to erosion and rupture of the pseudoaneurysm into adjacent thoracic structures. Although thoracic endovascular aortic repair (TEVAR) is the standard treatment method for aneurysm closure of the ductus arteriosus diverticulum, it was not possible in our patient secondary to marked aortoiliac access vessel tortuosity, significant vascular calcific burden, and an abdominal aortic aneurysm. We describe the first reported case of endovascular coil embolization being successfully used as the definite repair of a ductus arteriosus diverticulum pseudoaneurysm.Case presentationAn 85-year-old man with history of severe coronary arterial disease presented with an enlarging pseudoaneurysm of a ductus arteriosus diverticulum. The diverticulum and thoracic aortic junction demonstrated the typical obtuse angles and wide neck, differentiating it from otherwise similar-appearing diagnostic considerations. Repair was attempted with conventional aortic stent graft but the patient's infrarenal abdominal aortic aneurysm and his heavily calcified, tortuous iliac vessels could not accommodate the 24Fr introducer sheath necessary for stent graft placement. Therefore, endovascular coil embolization was successfully completed through a 4Fr directional catheter. The patient tolerated the procedure well and was discharged from the hospital in good condition on post-embolization day six.ConclusionsEndovascular coil embolization is an alternative treatment for ductus arteriosus diverticulum pseudoaneurysm closure in cases where the standard TEVAR method is unsuccessful. Instead of the wide entry point at the aorta we used the junction of the diverticulum and pseudoaneurysm as the "neck" for satisfactory and stable coil placement. Endovascular coil embolization alone may be a viable definitive therapy for occlusion of the ductus pseudoaneurysm component of the diverticulum in cases where complex anatomy or extensive vascular disease makes stent graft repair impractical if not impossible.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Endovascular coil embolization of residual or recurrent aneurysms after surgical clipping
    Cekirge, HS
    Islak, C
    Firat, MM
    Kocer, N
    Saatci, I
    ACTA RADIOLOGICA, 2000, 41 (02) : 111 - 115
  • [32] ENDOVASCULAR PLATINUM COIL EMBOLIZATION OF INCOMPLETELY SURGICALLY CLIPPED CEREBRAL ANEURYSMS
    FRASER, KW
    HALBACH, VV
    TEITELBAUM, GP
    SMITH, TP
    HIGASHIDA, RT
    DOWD, CF
    WILSON, CB
    HIESHIMA, GB
    SURGICAL NEUROLOGY, 1994, 41 (01): : 4 - 8
  • [33] ENDOVASCULAR COIL EMBOLIZATION OF UNUSUAL POSTERIOR INFERIOR CEREBELLAR ARTERY ANEURYSMS
    DOWD, CF
    HALBACH, VV
    HIGASHIDA, RT
    BARNWELL, SL
    HIESHIMA, GB
    NEUROSURGERY, 1990, 27 (06) : 954 - 961
  • [34] Successful Endovascular Management of Pseudoaneurysm following Transarterial Chemoembolization: A Case Report
    Jang, Joo Yeon
    Kim, Tae Un
    Ryu, Hwaseong
    Yoon, Ki Tae
    Hong, Young Mi
    Jeon, Ung Bae
    MEDICINA-LITHUANIA, 2024, 60 (05):
  • [35] Isolated internal iliac artery infected pseudoaneurysm occlusion using endovascular coil embolisation
    Rohith, Gorrepati
    Rajesh, Bachavarahalli Sriramareddy
    Abdulbasith, K. M.
    Sureshkumar, Sathasivam
    BMJ CASE REPORTS, 2021, 14 (06)
  • [36] Endovascular coil embolization of cerebral aneurysm remnants after incomplete surgical obliteration
    Rabinstein, AA
    Nichols, DA
    STROKE, 2002, 33 (07) : 1809 - 1815
  • [37] Endovascular treatment of intracranial aneurysms using coil embolization plus an Enterprise stent
    Xu Xiang
    Shang Xiao-ming
    Cui Jian-zhong
    Wang Da-yong
    CHINESE MEDICAL JOURNAL, 2011, 124 (04) : 611 - 614
  • [38] Embolization of perigraft leaks after endovascular stent-graft treatment of distal arch anastomotic pseudoaneurysm with coil and n-butyl 2-cyanoacrylate
    Yamaguchi, T
    Maeda, M
    Abe, H
    Okada, T
    Kawaguchi, H
    Yamanouchi, E
    Sakuyama, K
    Uchida, H
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) : 61 - 64
  • [39] Endovascular coil embolization of the left internal carotid artery aneurysm - case report
    Lipowski, Adam
    Aboul-Hassan, Sleiman
    Krasinski, Zbigniew
    Woronowicz, Konrad
    POLISH JOURNAL OF SURGERY, 2021, 93 (05) : 1 - 3
  • [40] Hepatic artery pseudoaneurysm after pancreaticoduodenectomy treated with coil embolization in combination with portomesenteric venous stenting
    Han, Seung Chul
    Kim, Tae Hwan
    Yang, Hee Chul
    Chong, Jae Uk
    INTERNATIONAL JOURNAL OF GASTROINTESTINAL INTERVENTION, 2020, 9 (03): : 121 - 124