Novel gadolinium poly(vinyl chloride) membrane sensor based on a new S-N Schiff's base

被引:99
|
作者
Ganjali, MR
Emami, M
Rezapour, M
Shamsipur, M
Maddah, B
Salavati-Niasari, M
Hosseini, M
Talebpoui, Z
机构
[1] Univ Tehran, Dept Chem, Tehran, Iran
[2] Razi Univ, Dept Chem, Kermanshah, Iran
[3] Kashan Univ, Dept Chem, Kashan, Iran
[4] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
关键词
potentiometry; Gd(III) ion-selective electrode; PVC membrane; S-N Schiff's base;
D O I
10.1016/S0003-2670(03)00921-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a novel gadolinium membrane sensor based on new S-N Schiff s base (2-[{3-[(2-sulfanylphenyl)imino)- 1-methylbutylidene}amino]phenyl hydrosulfide (SMPH) is presented. The sensor displays a linear dynamic range between 1.0 x 10(-1) and 1.0 x 10(-5) M, with a nice Nernstian slope of 19.8 +/- 0.3 mV per decade and a detection limit of 3.0 x 10(-6) M. The best performance was obtained with a membrane composition of 33% poly(vinyl chloride), 61% benzyl acetate, 2% sodium tetraphenyl borate and 5% SMPH. The potentiometric response of the sensor is independent of the pH of the solution in the pH range of 4.0-8.0. The sensor possesses the advantages of short conditioning time, very fast response time, and especially, very good selectivity towards a large number of cations, such as Sm(III), Ce(III), La(III), Cu(II), Pb(II) and Hg(II). The electrode can be used for at least 9 weeks without any considerable divergence in the potentials. It was used as an indicator electrode in potentiometric titration of Gd(III) ions with EDTA, and recovery of Gd(III) from various binary mixtures. The electrode was also applied to the determination of Gd(III) in a urine sample. (C) 2003 Published by Elsevier B.V.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 50 条
  • [1] Novel Lu(III) membrane sensor based on a new asymmetrically S-N Schiff's base
    Ganjali, Mohammed Reza
    Tamaddon, Atefeh
    Norouzi, Parviz
    Adib, Mehdi
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01) : 194 - 199
  • [2] Novel Y(III) PVC-based membrane microelectrode based on a new S-N Schiff's base
    Ganjali, MR
    Daftari, A
    Nourozi, P
    Salavati-Niasari, M
    ANALYTICAL LETTERS, 2003, 36 (08) : 1511 - 1522
  • [3] Fabrication of a highly selective Eu(III) membrane sensor based on a new S-N hexadentates Schiff's base
    Ganjali, Mohammad Reza
    Norouzi, Parviz
    Daftari, Azadeh
    Faridbod, Farnoush
    Salavati-Niasari, Masoud
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 120 (02) : 673 - 678
  • [4] Novel lanthanum(III) membrane sensor based on a new N-S Schiff's base
    Ganjali, MR
    Qomi, M
    Daftari, A
    Norouzi, P
    Salavati-Niasari, M
    Rabbani, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 98 (01) : 92 - 96
  • [5] A novel lutetium(III) PVC membrane sensor based on a new symmetric S-N Schiff's base for Lu(III) analysis in real sample
    Zamani, Hassan Ali
    Rohani, Mitra
    Zangeneh-Asadabadi, Abbas
    Zabihi, Mohammad Saleh
    Ganjali, Mohammad Reza
    Salavati-Niasari, Masoud
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (06): : 917 - 920
  • [6] Highly selective thiocyanate poly(vinyl chloride) membrane electrode based on a cadmium–Schiff’s base complex
    M. R. Ganjali
    Tahereh Poursaberi
    Fatemeh Basiripour
    Masoud Salavati-Niassari
    Mohammad Yousefi
    Mojtaba Shamsipur
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 1091 - 1095
  • [7] A new pentadentate S-N Schiffs' base as a novel lonophore in construction of a novel Gd(III) membrane sensor
    Ganjali, MR
    Rezapour, M
    Norouzi, P
    Salavati-Niasari, M
    ELECTROANALYSIS, 2005, 17 (22) : 2032 - 2036
  • [8] Ruthenium(III) Schiff's base complex as novel chloride selective membrane sensor
    Ganjali, MR
    Pourjavid, MR
    Rezapour, M
    Poursaberi, T
    Daftari, A
    Salavati-Niasari, M
    ELECTROANALYSIS, 2004, 16 (11) : 922 - 927
  • [9] Highly selective thiocyanate poly(vinyl chloride) membrane electrode based on a cadmium-Schiff's base complex
    Ganjali, MR
    Poursaberi, T
    Basiripour, F
    Salavati-Niasari, M
    Yousefi, M
    Shamsipur, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08): : 1091 - 1095
  • [10] La(III) selective membrane sensor based on a new N-N Schiff's base
    Ganjali, MR
    Matloobi, P
    Ghorbani, M
    Norouzi, P
    Salavati-Niasari, M
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2005, 26 (01) : 38 - 42