Evaluation of Three Deformable Image Registration Techniques Between CT and CBCT in Prostate Cancer Radiation Therapy

被引:1
|
作者
Pirozzi, S. [1 ]
Kruzer, A. [1 ]
Richmond, H. [1 ]
Nelson, A. S. [1 ]
机构
[1] MIM Software Inc, Cleveland, OH USA
关键词
D O I
10.1016/j.ijrobp.2018.07.1526
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
TU_39_3279
引用
收藏
页码:E546 / E547
页数:2
相关论文
共 50 条
  • [1] Establishment of Benchmark CBCT/CT Deformable Image Registration in Radiation Therapy of Prostate Cancer
    Kumar, S.
    Siddiqui, S. U.
    Yechieli, R.
    Shah, M.
    Robbins, J.
    El Saka, R.
    Elshaikh, M.
    Pradhan, D.
    Kim, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S814 - S814
  • [2] Evaluation of the Accuracy of Deformable Image Registration of Individual Structures Between CT and CBCT in Prostate Cancer Radiotherapy
    Hammers, J.
    Pirozzi, S.
    Matney, J.
    Kaidar-Person, O.
    Chen, R.
    Wang, A.
    Das, S.
    Mavroidis, P.
    MEDICAL PHYSICS, 2017, 44 (06) : 3219 - 3219
  • [3] DEFORMABLE IMAGE REGISTRATION FOR CONTOUR PROPAGATION FROM CT TO CBCT IN RADIOTHERAPY OF PROSTATE CANCER
    Thor, M.
    Petersen, J.
    Bentzen, L.
    Hoyer, M.
    Muren, L. P.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S480 - S480
  • [4] Evaluation of Deformable Image Registration Methods Between MRI and CT for Prostate Cancer Radiotherapy
    Wen, N.
    -Hurst, C. Glide
    Zhong, H.
    Chin, K.
    Kumarasiri, A.
    Liu, C.
    Liu, M.
    Siddiqui, S.
    Chetty, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 99 - 99
  • [5] A Novel Approach for Establishing Benchmark CBCT/CT Deformable Image Registrations in Prostate Cancer Radiation Therapy
    Kim, J.
    Kumar, S.
    Liu, C.
    Zhong, H.
    Robbins, J.
    Pradhan, D.
    Elshaikh, M.
    Chetty, I. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S713 - S713
  • [6] Quantitative Analysis of the Accuracy of CT to CBCT Deformable Image Registration for Contour Mapping for Prostate Cancer
    Schmidt, R.
    Dogan, N.
    Ford, J.
    Studenski, M.
    Abramowitz, M.
    Padgett, K.
    Spieler, B.
    Xu, Y.
    Delgadillo, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [7] Quantitative evaluation of a cone beam computed tomography (CBCT)-CT deformable image registration method for adaptive radiation therapy
    Lawson, J. D.
    Schreibmann, E.
    Jani, A. B.
    Fox, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S709 - S709
  • [8] Evaluation of Deformable Image Registration Between High Dose Rate Brachytherapy and Intensity Modulated Radiation Therapy for Prostate Cancer
    Yokoyama, Noriomi
    Takemura, Akihiro
    Kojima, Hironori
    Tsukamoto, Kousuke
    Ueda, Shinichi
    Noto, Kimiya
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 505 - 508
  • [9] Virtual CT for adaptive prostate radiotherapy based on CT-CBCT deformable image registration
    Cassetta Junior, F. R.
    Ciardo, D.
    Fattori, G.
    Riboldi, M.
    Orecchia, R.
    Jereczek-Fossa, B. A.
    Baroni, G.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S902 - S903
  • [10] Deformable Registration Between CT and Truncated CBCT for Adaptive Therapy Dose Calculation
    Zhen, X.
    Graves, Y.
    Yan, H.
    Zhou, L.
    Jia, X.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3961 - 3961