The effect of high thermal insulation on high thermal mass: Is the dynamic behaviour of traditional envelopes in Mediterranean climates still possible?

被引:56
作者
Stazi, Francesca [1 ]
Bonfigli, Cecilia [1 ]
Tomassoni, Elisa [1 ]
Di Perna, Costanzo [2 ]
Munafo, Placido [1 ]
机构
[1] Univ Politecn Marche, Fac Ingn, DICEA, I-60731 Ancona, Italy
[2] Univ Politecn Marche, Fac Ingn, Dipartimento Ingn Ind & Sci Matemat, I-60731 Ancona, Italy
关键词
Optimal building envelope; Energy efficient retrofitting; Energy saving; Comfort; Global cost; Dynamic thermal insulation; TEMPERATURE-VARIATIONS; INDOOR TEMPERATURES; DECREMENT FACTOR; BUILDING WALLS; EXTERNAL WALLS; TIME-LAG; PERFORMANCE; CONSTRUCTIONS; STRATEGIES; THICKNESS;
D O I
10.1016/j.enbuild.2014.11.056
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper aims at studying the effect of both high thermal insulation and high thermal mass techniques in buildings dynamic behaviour in Mediterranean climates. The two techniques can lead to conflicting requirements when considering winter and summer conditions, or even high daily temperature ranges. Therefore, the best solution for the summer can be the worst solution for the winter. It is necessary to identify insulation measures that conserve the mass dynamic behaviour. Experimental investigations were carried out on a single-family house to characterize the behaviour of two walls with different thermal inertia. Thermal simulations made it possible to explore different retrofit configurations also including dynamic strategies. The solutions were compared on comfort, energy savings and global cost. The study shows that the most suitable intervention is the maximization of the internal heat capacity and the introduction of an external insulation layer sealed in wintertime and ventilated in summer, thus maintaining the existing massive envelope seasonal dynamic behaviour by alternatively maximising thermal barrier effect and heat loss. Considering this, the authors introduced a recently patented dynamic system that reduces both summer discomfort levels and consumption, respectively, of about 20% and 43% respect to the worst retrofit solution. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 383
页数:17
相关论文
共 48 条
[1]  
AEEG, 2008, 308 EEN AEEG
[2]   Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential [J].
Al-Sanea, Sami A. ;
Zedan, M. F. ;
Al-Hussain, S. N. .
APPLIED ENERGY, 2012, 89 (01) :430-442
[3]   Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass [J].
Al-Sanea, Sami A. ;
Zedan, M. F. .
APPLIED ENERGY, 2011, 88 (09) :3113-3124
[4]  
Anmelder G., 2005, [Fassadenwarme-Damm-Verbundsystem, Patent], Patent No. [DE102004001601, 102004001601]
[5]  
[Anonymous], 2011, 10375 UNI NAT STAND
[6]  
[Anonymous], 2013, TIPOGRAFIA GENIOCVIL
[7]  
[Anonymous], 2012, ELAB EUR DAT DOM CON
[8]  
[Anonymous], 15251 EN
[9]  
[Anonymous], 2002, 77262002 UNI EN ISO
[10]  
[Anonymous], 2014, [No title captured], Patent No. 0001407018