CREATION AND USE OF ADJUSTABLE 3D PHANTOMS: APPLICATION FOR THE LUNG MONITORING OF FEMALE WORKERS

被引:14
作者
Farah, Jad [1 ]
Broggio, David [1 ]
Franck, Didier [1 ]
机构
[1] IRSN, DRPH SDI LEDI, F-92262 Fontenay Aux Roses, France
来源
HEALTH PHYSICS | 2010年 / 99卷 / 05期
关键词
counting efficiency; dosimetry; internal; lungs; human; phantom; CHEST-WALL-THICKNESS; RADIATION PROTECTION DOSIMETRY; MONTE-CARLO CALCULATIONS; ADULT VOXEL PHANTOM; COMPUTATIONAL PHANTOMS; COUNTING EFFICIENCY; INTERNAL DOSIMETRY; FAST CONSTRUCTION; MCNP CALCULATIONS; BREAST VOLUME;
D O I
10.1097/HP.0b013e3181dc4f58
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In vivo counting measurements, used for the monitoring of workers with internal contamination risks, are based on the use of calibration physical phantoms. However, such phantoms do not exist for female subjects. Computational calibration using numerical representations, Mesh and non-uniform rational basis spline (NURBS) geometries, was thus considered. The study presented here is focused on the creation of different female thoracic phantoms with various breast sizes and chest girths. These 3D models are used to estimate the radiation attenuation with morphology and the resulting variation of the calibration coefficient of a typical 4-germanium in vivo counting system. A basic Mesh female thoracic phantom was created from the International Commission on Radiological Protection Adult Female Reference Computational Phantom. Using this basic phantom, different chest girths (85, 90, 100, 110, and 120) and cup sizes (A to F) were created representing the most common thoracic female morphologies, as recommended by the available and relevant literature. Variation of breast tissue composition and internal organ volumes with morphology were also considered. As a result, 34 thoracic female phantoms were created combining different cup sizes and chest girths. For the 85 chest girth, at very low energies (15 keV), a relative counting efficiency variation of about 85% was observed between the A and E cups. As a result of this study, breast size dependent calibration coefficients, between 15 keV and 1.4 MeV, were obtained and tabulated for a typical lung counting germanium system. Health Phys. 99(5):649-661; 2010
引用
收藏
页码:649 / 661
页数:13
相关论文
共 55 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   A high-resolution anthropomorphic voxel-based tomographic phantom for proton therapy of the eye [J].
Alghamdi, A. A. ;
Ma, A. ;
Marouli, M. ;
Albarakati, Y. ;
Kacperek, A. ;
Spyrou, N. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02) :N51-N59
[3]  
[Anonymous], 2006, BOUNDARY REPRESENTAT
[4]  
BECKER J, 2006, WORLD C MED PHYS BIO, P1967
[5]   BIOMETRIC ESTIMATION OF CHEST WALL THICKNESS OF FEMALES [J].
BERGER, CD ;
LANE, BH .
HEALTH PHYSICS, 1985, 49 (03) :419-424
[6]   A new graphical user interface for fast construction of computation phantoms and MCNP calculations: Application to calibration of in vivo measurement systems [J].
Borisov, N ;
Franck, D ;
de Carlan, L ;
Laval, L .
HEALTH PHYSICS, 2002, 83 (02) :272-279
[7]   Validation of a personalized dosimetric evaluation tool (Oedipe) for targeted radiotherapy based on the Monte Carlo MCNPX code [J].
Chiavassa, S ;
Aubineau-Lanièce, I ;
Bitar, A ;
Lisbona, A ;
Barbet, J ;
Franck, D ;
Jourdain, JR ;
Bardiès, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (03) :601-616
[8]   Improvement of internal dose calculations using mathematical models of different adult heights [J].
Clairand, I ;
Bouchet, LG ;
Ricard, M ;
Durigon, M ;
Di Paola, M ;
Aubert, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :2771-2785
[9]   Organ weight in 684 adult autopsies: new tables for a Caucasoid population [J].
de la Grandmaison, GL ;
Clairand, I ;
Durigon, M .
FORENSIC SCIENCE INTERNATIONAL, 2001, 119 (02) :149-154
[10]   RELATIONSHIP BETWEEN LIVER SIZE AND BODY SIZE [J].
DELAND, FH ;
NORTH, WA .
RADIOLOGY, 1968, 91 (06) :1195-&