Direct competitive immunosensor for Imidacloprid pesticide detection on gold nanoparticle-modified electrodes

被引:53
作者
Perez-Fernandez, Beatriz [1 ]
Mercader, Josep V. [2 ]
Abad-Fuentes, Antonio [2 ]
Checa-Orrego, Brenda I. [3 ]
Costa-Garcia, Agustin [1 ]
de la Escosura-Muniz, Alfredo [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, NanoBioanal Grp, Julian Claveria 8, E-33006 Oviedo, Spain
[2] CSIC, IATA, Avda Agusti Escardino 7, Valencia 46980, Spain
[3] Minist Desarrollo Agr DNSV, Panama City, Panama
关键词
Electrochemical immunosensor; Screen-printed carbon electrodes; Imidacloprid; Point-of-use; Pesticides; Nanoparticles; SCREEN-PRINTED ELECTRODES; NONENZYMATIC ELECTROCHEMICAL SENSOR; WALLED CARBON NANOTUBES; REDUCED GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; BIOSENSOR; ACETYLCHOLINESTERASE; SAMPLES; WATER; NANOWIRES;
D O I
10.1016/j.talanta.2019.120465
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct competitive immunosensor for the electrochemical determination of Imidacloprid (IMD) pesticide on gold nanoparticle-modified screen-printed carbon electrodes (AuNP-SPCE) is here reported for the first time. Self-obtained specific monoclonal antibodies are immobilized on the AuNP-SPCE taking advantage of the AuNPs biofunctionalization abilities. In our biosensor design, free IMD in the sample competes with IMD conjugated with horseradish peroxidase (IMD-HRP) for the recognition by the antibodies. After that, 3,3'5,5'-Tetramethylbenzidine (TMB) is enzymatically oxidized by HRP, followed by the oxidized TMB reduction back at the surface of the SPCE. This process gives an associated catalytic current (analytical signal) that is inversely proportional to the IMD amount. The main parameters affecting the analytical signal have been optimized, reaching a good precision (repeatability with a RSD of 6%), accuracy (relative error of 6%), stability (up to one month), selectivity and an excellent limit of detection (LOD of 22 pmol L-1), below the maximum levels allowed by the legislation, with a wide response range (50-10000 pmol L--(1)). The detection through antibodies also allows to have an excellent selectivity against other pesticides potentially present in real samples. Low matrix effects were found when analysing IMD in tap water and watermelon samples. The electrochemical immunosensor was also validated with HPLC-MS/MS, the reference method used in official laboratories for IMD analysis, through statistical tests. Our findings make the electrochemical immunosensor as an outstanding method for the rapid and sensitive determination of IMD at the point-of-use.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Gold Nanoparticle Modified Screen Printed Electrodes for the Trace Sensing of Arsenic(III) in the Presence of Copper(II)
    Khairy, Mohamed
    Kampouris, Dimitrios K.
    Kadara, Rashid O.
    Banks, Craig E.
    [J]. ELECTROANALYSIS, 2010, 22 (21) : 2496 - 2501
  • [42] Gold nanoparticle-modified sustainable plastic sensor chip for voltammetric monitoring of Hg(II)
    Karapa, Alexandra
    Kokkinos, Christos
    Fielden, Peter R.
    Baldock, Sara J.
    Goddard, Nickolas J.
    Economou, Anastasios
    [J]. TALANTA, 2023, 265
  • [43] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    [J]. ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [44] Densitometry determination of oestrogenic EDCs with gold nanoparticle-modified oestrogen response element assay
    Gao, Yu-Qiu
    Chen, Tian
    Wan, Yan-Jian
    Li, Yuan-Yuan
    Xu, Shun-Qing
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (05) : 401 - 409
  • [45] Sol-Gel/Chitosan/Gold Nanoparticle-Modified Electrode in Mediated Bacterial Biosensor
    Habib, Omer
    Demirkol, Dilek Odaci
    Timur, Suna
    [J]. FOOD ANALYTICAL METHODS, 2012, 5 (02) : 188 - 194
  • [46] A Gold Nanoparticle-Modified Carbon Paste Electrode as a Sensor for Simultaneous Determination of Acetaminophen and Atenolol
    Behpour, Mohsen
    Ghoreishi, Sayed Mehdi
    Honarmand, Ebrahim
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (12): : 1922 - 1933
  • [47] A novel electrochemical immunosensor based on hydrogen evolution inhibition by enzymatic copper deposition on platinum nanoparticle-modified electrode
    Huang, Yong
    Wen, Qian
    Jiang, Jian-Hui
    Shen, Guo-Li
    Yu, Ru-Qin
    [J]. BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) : 600 - 605
  • [48] The development of modified gold nanoparticle for detection of arsenic
    Niyomthai, Saowapa T.
    Supaphol, Pitt
    Niyomthai, Prachaya
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 52 : 2505 - 2511
  • [49] Hierarchical optical antenna: Gold nanoparticle-modified photonic crystal for highly-sensitive label-free DNA detection
    Shen, Weizhi
    Li, Mingzhu
    Wang, Benli
    Liu, Jian
    Li, Zhiyuan
    Jiang, Lei
    Song, Yanlin
    [J]. JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (16) : 8127 - 8133
  • [50] An ultrasensitive electrochemical immunosensor for carcinoembryonic antigen detection based on staphylococcal protein A-Au nanoparticle modified gold electrode
    Zhou, Jie
    Du, Liping
    Zou, Ling
    Zou, Yingchang
    Hu, Ning
    Wang, Ping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 197 : 220 - 227