Direct competitive immunosensor for Imidacloprid pesticide detection on gold nanoparticle-modified electrodes

被引:53
作者
Perez-Fernandez, Beatriz [1 ]
Mercader, Josep V. [2 ]
Abad-Fuentes, Antonio [2 ]
Checa-Orrego, Brenda I. [3 ]
Costa-Garcia, Agustin [1 ]
de la Escosura-Muniz, Alfredo [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, NanoBioanal Grp, Julian Claveria 8, E-33006 Oviedo, Spain
[2] CSIC, IATA, Avda Agusti Escardino 7, Valencia 46980, Spain
[3] Minist Desarrollo Agr DNSV, Panama City, Panama
关键词
Electrochemical immunosensor; Screen-printed carbon electrodes; Imidacloprid; Point-of-use; Pesticides; Nanoparticles; SCREEN-PRINTED ELECTRODES; NONENZYMATIC ELECTROCHEMICAL SENSOR; WALLED CARBON NANOTUBES; REDUCED GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; BIOSENSOR; ACETYLCHOLINESTERASE; SAMPLES; WATER; NANOWIRES;
D O I
10.1016/j.talanta.2019.120465
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A direct competitive immunosensor for the electrochemical determination of Imidacloprid (IMD) pesticide on gold nanoparticle-modified screen-printed carbon electrodes (AuNP-SPCE) is here reported for the first time. Self-obtained specific monoclonal antibodies are immobilized on the AuNP-SPCE taking advantage of the AuNPs biofunctionalization abilities. In our biosensor design, free IMD in the sample competes with IMD conjugated with horseradish peroxidase (IMD-HRP) for the recognition by the antibodies. After that, 3,3'5,5'-Tetramethylbenzidine (TMB) is enzymatically oxidized by HRP, followed by the oxidized TMB reduction back at the surface of the SPCE. This process gives an associated catalytic current (analytical signal) that is inversely proportional to the IMD amount. The main parameters affecting the analytical signal have been optimized, reaching a good precision (repeatability with a RSD of 6%), accuracy (relative error of 6%), stability (up to one month), selectivity and an excellent limit of detection (LOD of 22 pmol L-1), below the maximum levels allowed by the legislation, with a wide response range (50-10000 pmol L--(1)). The detection through antibodies also allows to have an excellent selectivity against other pesticides potentially present in real samples. Low matrix effects were found when analysing IMD in tap water and watermelon samples. The electrochemical immunosensor was also validated with HPLC-MS/MS, the reference method used in official laboratories for IMD analysis, through statistical tests. Our findings make the electrochemical immunosensor as an outstanding method for the rapid and sensitive determination of IMD at the point-of-use.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Tin nanoparticle-modified electrode for the simultaneous detection of cadmium (Cd) and lead (Pb) ions
    Ramli, Nurul Hidayah
    Loo, Ji Yu
    Mohamad Nor, Noorhashimah
    Abdul Razak, Khairunisak
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2024, 35 (01)
  • [32] Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
    Martins, Beatriz R.
    Barbosa, Yanne O.
    Andrade, Cristhianne M. R.
    Pereira, Loren Q.
    Simao, Guilherme F.
    de Oliveira, Carlo J.
    Correia, Dalmo
    Oliveira Jr, Robson T. S.
    da Silva, Marcos, V
    Silva, Anielle C. A.
    Dantas, Noelio O.
    Rodrigues Jr, Virmondes
    Munoz, Rodrigo A. A.
    Alves-Balvedi, Renata P.
    BIOSENSORS-BASEL, 2020, 10 (08):
  • [33] Cholesterol biosensor based on inkjet-printed Prussian blue nanoparticle-modified screen-printed electrodes
    Cinti, Stefano
    Arduini, Fabiana
    Moscone, Danila
    Palleschi, Giuseppe
    Gonzalez-Macia, Laura
    Killard, Anthony J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 187 - 190
  • [34] Oxcarbazepine Analysis by Adsorptive Stripping Voltammetry Using Silver Nanoparticle-Modified Carbon Screen-Printed Electrodes
    Dominguez-Renedo, Olga
    Burgoa Calvo, M. Encarnacion
    Asuncion Alonso-Lomillo, M.
    Julia Arcos-Martinez, M.
    SENSOR LETTERS, 2010, 8 (02) : 268 - 272
  • [35] Immobilization of rat brain acetylcholinesterase on porous gold-nanoparticle-CaCO3 hybrid material modified Au electrode for detection of organophosphorous insecticides
    Chauhan, Nidhi
    Narang, Jagriti
    Pundir, C. S.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2011, 49 (05) : 923 - 929
  • [36] Electrochemical immunosensor for Enterobacter sakazakii detection based on electrochemically reduced graphene oxide-gold nanoparticle/ionic liquid modified electrode
    Hu, Xue
    Dou, Wenchao
    Zhao, Guangying
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 : 43 - 48
  • [37] Characterisation of screen-printed gold and gold nanoparticle-modified carbon sensors by electrochemical impedance spectroscopy
    Bernalte, Elena
    Marin-Sanchez, Carmen
    Pinilla-Gil, Eduardo
    Brett, Christopher M. A.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 709 : 70 - 76
  • [38] Nano-engineered Flavin-Dependent Glucose Dehydrogenase/Gold Nanoparticle-Modified Electrodes for Glucose Sensing and Biofuel Cell Applications
    Yehezkeli, Omer
    Tel-Vered, Ran
    Reichlin, Sara
    Willner, Itamer
    ACS NANO, 2011, 5 (03) : 2385 - 2391
  • [39] Impedimetric Immunosensor Utilizing Polyaniline/Gold Nanocomposite-Modified Screen-Printed Electrodes for Early Detection of Chronic Kidney Disease
    Shaikh, Muhammad Omar
    Srikanth, Boyanagunta
    Zhu, Pei-Yu
    Chuang, Cheng-Hsin
    SENSORS, 2019, 19 (18)
  • [40] Electrochemical Detection of Cardiac Biomarker Troponin I at Gold Nanoparticle-Modified ITO Electrode by Using Open Circuit Potential
    Ahammad, A. J. Saleh
    Choi, Yo-Han
    Koh, Kwangnak
    Kim, Jae-Ho
    Lee, Jae-Joon
    Lee, Minsu
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (06): : 1906 - 1916